Search Results (323552 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2020-16233 1 Wibu 1 Codemeter 2024-11-21 7.5 High
An attacker could send a specially crafted packet that could have CodeMeter (All versions prior to 7.10) send back packets containing data from the heap.
CVE-2020-16230 1 Hms-networks 4 Ewon Cosy, Ewon Cosy Firmware, Ewon Flexy and 1 more 2024-11-21 2.3 Low
All version of Ewon Flexy and Cosy prior to 14.1 use wildcards such as (*) under which domains can request resources. An attacker with local access and high privileges could inject scripts into the Cross-origin Resource Sharing (CORS) configuration that could abuse this vulnerability, allowing the attacker to retrieve limited confidential information through sniffing.
CVE-2020-16229 1 Advantech 1 Webaccess\/hmi Designer 2024-11-21 7.8 High
Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Processing specially crafted project files lacking proper validation of user supplied data may cause a type confusion condition, which may allow remote code execution, disclosure/modification of information, or cause the application to crash.
CVE-2020-16228 1 Philips 24 Intellivue Mp2-mp90, Intellivue Mp2-mp90 Firmware, Intellivue Mx100 and 21 more 2024-11-21 6.4 Medium
In Patient Information Center iX (PICiX) Versions C.02 and C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and prior, the software does not check or incorrectly checks the revocation status of a certificate, which may cause it to use a compromised certificate.
CVE-2020-16227 1 Deltaww 1 Tpeditor 2024-11-21 7.8 High
Delta Electronics TPEditor Versions 1.97 and prior. An improper input validation may be exploited by processing a specially crafted project file not validated when the data is entered by a user. Successful exploitation of this vulnerability may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application.
CVE-2020-16226 1 Mitsubishielectric 186 Conveyor Tracking Application Apr-ntr12fh, Conveyor Tracking Application Apr-ntr20fh\(n\=1\,2\), Conveyor Tracking Application Apr-ntr3fh and 183 more 2024-11-21 9.8 Critical
Multiple Mitsubishi Electric products are vulnerable to impersonations of a legitimate device by a malicious actor, which may allow an attacker to remotely execute arbitrary commands.
CVE-2020-16225 1 Deltaww 1 Tpeditor 2024-11-21 7.8 High
Delta Electronics TPEditor Versions 1.97 and prior. A write-what-where condition may be exploited by processing a specially crafted project file. Successful exploitation of this vulnerability may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application.
CVE-2020-16224 1 Philips 1 Patient Information Center Ix 2024-11-21 6.5 Medium
In Patient Information Center iX (PICiX) Versions C.02, C.03, the software parses a formatted message or structure but does not handle or incorrectly handles a length field that is inconsistent with the actual length of the associated data, causing the application on the surveillance station to restart.
CVE-2020-16223 1 Deltaww 1 Tpeditor 2024-11-21 7.8 High
Delta Electronics TPEditor Versions 1.97 and prior. A heap-based buffer overflow may be exploited by processing a specially crafted project file. Successful exploitation of this vulnerability may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application.
CVE-2020-16222 1 Philips 2 Patient Information Center Ix, Performancebridge Focal Point 2024-11-21 8.8 High
In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and PerformanceBridge Focal Point Version A.01, when an actor claims to have a given identity, the software does not prove or insufficiently proves the claim is correct.
CVE-2020-16221 1 Deltaww 1 Tpeditor 2024-11-21 7.8 High
Delta Electronics TPEditor Versions 1.97 and prior. A stack-based buffer overflow may be exploited by processing a specially crafted project file. Successful exploitation of this vulnerability may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application.
CVE-2020-16220 1 Philips 2 Patient Information Center Ix, Performancebridge Focal Point 2024-11-21 4.3 Medium
In Patient Information Center iX (PICiX) Versions C.02, C.03, PerformanceBridge Focal Point Version A.01, the product receives input that is expected to be well-formed (i.e., to comply with a certain syntax) but it does not validate or incorrectly validates that the input complies with the syntax, causing the certificate enrollment service to crash. It does not impact monitoring but prevents new devices from enrolling.
CVE-2020-16219 1 Deltaww 1 Tpeditor 2024-11-21 7.8 High
Delta Electronics TPEditor Versions 1.97 and prior. An out-of-bounds read may be exploited by processing specially crafted project files. Successful exploitation of this vulnerability may allow an attacker to read/modify information, execute arbitrary code, and/or crash the application.
CVE-2020-16218 1 Philips 1 Patient Information Center Ix 2024-11-21 3.5 Low
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and served to other users. Successful exploitation could lead to unauthorized access to patient data via a read-only web application.
CVE-2020-16217 1 Advantech 1 Webaccess\/hmi Designer 2024-11-21 7.8 High
Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. A double free vulnerability caused by processing specially crafted project files may allow remote code execution, disclosure/modification of information, or cause the application to crash.
CVE-2020-16216 1 Philips 24 Intellivue Mp2-mp90, Intellivue Mp2-mp90 Firmware, Intellivue Mx100 and 21 more 2024-11-21 6.5 Medium
In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, the product receives input or data but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly, which can induce a denial-of-service condition through a system restart.
CVE-2020-16215 1 Advantech 1 Webaccess\/hmi Designer 2024-11-21 7.8 High
Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Processing specially crafted project files lacking proper validation of user supplied data may cause a stack-based buffer overflow, which may allow remote code execution, disclosure/modification of information, or cause the application to crash.
CVE-2020-16214 1 Philips 1 Patient Information Center Ix 2024-11-21 5.0 Medium
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software saves user-provided information into a comma-separated value (CSV) file, but it does not neutralize or incorrectly neutralizes special elements that could be interpreted as a command when the file is opened by spreadsheet software.
CVE-2020-16213 1 Advantech 1 Webaccess\/hmi Designer 2024-11-21 7.8 High
Advantech WebAccess HMI Designer, Versions 2.1.9.31 and prior. Processing specially crafted project files lacking proper validation of user supplied data may cause the system to write outside the intended buffer area, which may allow remote code execution, disclosure/modification of information, or cause the application to crash.
CVE-2020-16212 1 Philips 1 Patient Information Center Ix 2024-11-21 6.8 Medium
In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on the surveillance station operates in kiosk mode, which is vulnerable to local breakouts that could allow an attacker with physical access to escape the restricted environment with limited privileges.