Filtered by vendor Tenda
Subscriptions
Filtered by product Ac10
Subscriptions
Total
57 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2023-37144 | 2 Tenda, Tendacn | 2 Ac10, Ac10 Firmware | 2024-08-02 | 9.8 Critical |
Tenda AC10 v15.03.06.26 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac. | ||||
CVE-2023-34570 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-08-02 | 6.7 Medium |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter devName at /goform/SetOnlineDevName. | ||||
CVE-2023-34569 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-08-02 | 6.7 Medium |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList. | ||||
CVE-2023-34567 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-08-02 | 6.7 Medium |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg. | ||||
CVE-2023-34566 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-08-02 | 9.8 Critical |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/saveParentControlInfo. | ||||
CVE-2023-34571 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-08-02 | 6.7 Medium |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter shareSpeed at /goform/WifiGuestSet. | ||||
CVE-2023-34568 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-08-02 | 6.7 Medium |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet. | ||||
CVE-2023-27013 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-08-02 | 9.8 Critical |
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the get_parentControl_list_Info function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||||
CVE-2023-27021 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-08-02 | 9.8 Critical |
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the formSetFirewallCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||||
CVE-2023-27014 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-08-02 | 9.8 Critical |
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_46AC38 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||||
CVE-2023-27016 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-08-02 | 9.8 Critical |
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the R7WebsSecurityHandler function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||||
CVE-2023-27019 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-08-02 | 9.8 Critical |
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_458FBC function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||||
CVE-2023-27017 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-08-02 | 9.8 Critical |
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45DC58 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||||
CVE-2023-27020 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-08-02 | 9.8 Critical |
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the saveParentControlInfo function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||||
CVE-2023-27015 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-08-02 | 9.8 Critical |
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_4A75C0 function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||||
CVE-2023-27018 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-08-02 | 9.8 Critical |
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45EC1C function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||||
CVE-2023-27012 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-08-02 | 9.8 Critical |
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the setSchedWifi function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. |