Search Results (359347 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2022-36372 1 Intel 69 Bios, Nuc 8 Compute Element Cm8ccb4r, Nuc 8 Compute Element Cm8ccb4r Firmware and 66 more 2024-11-21 7.5 High
Improper buffer restrictions in some Intel(R) NUC BIOS firmware may allow a privileged user to potentially enable escalation of privilege via local access.
CVE-2022-36364 1 Apache 1 Apache Calcite Avatica 2024-11-21 8.8 High
Apache Calcite Avatica JDBC driver creates HTTP client instances based on class names provided via `httpclient_impl` connection property; however, the driver does not verify if the class implements the expected interface before instantiating it, which can lead to code execution loaded via arbitrary classes and in rare cases remote code execution. To exploit the vulnerability: 1) the attacker needs to have privileges to control JDBC connection parameters; 2) and there should be a vulnerable class (constructor with URL parameter and ability to execute code) in the classpath. From Apache Calcite Avatica 1.22.0 onwards, it will be verified that the class implements the expected interface before invoking its constructor.
CVE-2022-36363 1 Siemens 4 Logo\!8 Bm, Logo\!8 Bm Fs-05, Logo\!8 Bm Fs-05 Firmware and 1 more 2024-11-21 5.3 Medium
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices do not properly validate an offset value which can be defined in TCP packets when calling a method. This could allow an attacker to retrieve parts of the content of the memory.
CVE-2022-36362 1 Siemens 4 Logo\!8 Bm, Logo\!8 Bm Fs-05, Logo\!8 Bm Fs-05 Firmware and 1 more 2024-11-21 7.5 High
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable and could only be recovered by power cycling the device.
CVE-2022-36361 1 Siemens 4 Logo\!8 Bm, Logo\!8 Bm Fs-05, Logo\!8 Bm Fs-05 Firmware and 1 more 2024-11-21 9.8 Critical
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices do not properly validate the structure of TCP packets in several methods. This could allow an attacker to cause buffer overflows, get control over the instruction counter and run custom code.
CVE-2022-36360 1 Siemens 4 Logo\!8 Bm, Logo\!8 Bm Fs-05, Logo\!8 Bm Fs-05 Firmware and 1 more 2024-11-21 7.5 High
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Affected devices load firmware updates without checking the authenticity. Furthermore the integrity of the unencrypted firmware is only verified by a non-cryptographic method. This could allow an attacker to manipulate a firmware update and flash it to the device.
CVE-2022-36349 1 Intel 4 Nuc Board Nuc5i3mybe, Nuc Board Nuc5i3mybe Firmware, Nuc Kit Nuc5i3myhe and 1 more 2024-11-21 5.2 Medium
Insecure default variable initialization in BIOS firmware for some Intel(R) NUC Boards and Intel(R) NUC Kits before version MYi30060 may allow an authenticated user to potentially enable denial of service via local access.
CVE-2022-36345 1 Metagauss 1 Download Plugin 2024-11-21 4.3 Medium
Cross-Site Request Forgery (CSRF) vulnerability in Metagauss Download PluginĀ <= 2.0.4 versions.
CVE-2022-36344 1 Justsystems 60 Atok Medical 2, Atok Medical 3, Atok Pro 3 and 57 more 2024-11-21 9.8 Critical
An unquoted search path vulnerability exists in 'JustSystems JUST Online Update for J-License' bundled with multiple products for corporate users as in Ichitaro through Pro5 and others. Since the affected product starts another program with an unquoted file path, a malicious file may be executed with the privilege of the Windows service if it is placed in a certain path. Affected products are bundled with the following product series: Office and Office Integrated Software, ATOK, Hanako, JUST PDF, Shuriken, Homepage Builder, JUST School, JUST Smile Class, JUST Smile, JUST Frontier, JUST Jump, and Tri-De DetaProtect.
CVE-2022-36336 2 Microsoft, Trendmicro 4 Windows, Apex One, Worry-free Business Security and 1 more 2024-11-21 7.8 High
A link following vulnerability in the scanning function of Trend Micro Apex One and Worry-Free Business Security agents could allow a local attacker to escalate privileges on affected installations. The resolution for this issue has been deployed automatically via ActiveUpdate to customers in an updated Spyware pattern. Customers who are up-to-date on detection patterns are not required to take any additional steps to mitigate this issue.
CVE-2022-36322 1 Jetbrains 1 Teamcity 2024-11-21 5.4 Medium
In JetBrains TeamCity before 2022.04.2 build parameter injection was possible
CVE-2022-36321 1 Jetbrains 1 Teamcity 2024-11-21 4.1 Medium
In JetBrains TeamCity before 2022.04.2 the private SSH key could be written to the build log in some cases
CVE-2022-36312 1 Airspan 2 Airvelocity 1500, Airvelocity 1500 Firmware 2024-11-21 8.8 High
Airspan AirVelocity 1500 software version 15.18.00.2511 lacks CSRF protections in the eNodeB's web management UI. This issue may affect other AirVelocity and AirSpeed models.
CVE-2022-36311 1 Airspan 2 Airvelocity 1500, Airvelocity 1500 Firmware 2024-11-21 6.1 Medium
Airspan AirVelocity 1500 prior to software version 15.18.00.2511 is vulnerable to injection leading to XSS in the SNMP community field in the eNodeB's web management UI. This issue may affect other AirVelocity and AirSpeed models.
CVE-2022-36310 1 Airspan 2 Airvelocity 1500, Airvelocity 1500 Firmware 2024-11-21 8.8 High
Airspan AirVelocity 1500 software prior to version 15.18.00.2511 had NET-SNMP-EXTEND-MIB enabled on its snmpd service, enabling an attacker with SNMP write abilities to execute commands as root on the eNodeB. This issue may affect other AirVelocity and AirSpeed models.
CVE-2022-36309 1 Airspan 2 Airvelocity 1500, Airvelocity 1500 Firmware 2024-11-21 8.8 High
Airspan AirVelocity 1500 software versions prior to 15.18.00.2511 have a root command injection vulnerability in the ActiveBank parameter of the recoverySubmit.cgi script running on the eNodeB's web management UI. This issue may affect other AirVelocity and AirSpeed models.
CVE-2022-36308 1 Airspan 2 Airvelocity 1500, Airvelocity 1500 Firmware 2024-11-21 9.1 Critical
Airspan AirVelocity 1500 web management UI displays SNMP credentials in plaintext on software versions older than 15.18.00.2511, and stores SNMPv3 credentials unhashed on the filesystem, enabling anyone with web access to use these credentials to manipulate the eNodeB over SNMP. This issue may affect other AirVelocity and AirSpeed models.
CVE-2022-36307 1 Airspan 2 Airvelocity 1500, Airvelocity 1500 Firmware 2024-11-21 6.8 Medium
The AirVelocity 1500 prints SNMP credentials on its physically accessible serial port during boot. This was fixed in AirVelocity 1500 software version 15.18.00.2511 and may affect other AirVelocity and AirSpeed models.
CVE-2022-36306 1 Airspan 2 Airvelocity 1500, Airvelocity 1500 Firmware 2024-11-21 6.5 Medium
An authenticated attacker can enumerate and download sensitive files, including the eNodeB's web management UI's TLS private key, the web server binary, and the web server configuration file. These vulnerabilities were found in AirVelocity 1500 running software version 9.3.0.01249, were still present in 15.18.00.2511, and may affect other AirVelocity and AirSpeed models.
CVE-2022-36305 1 Vestacp 1 Vesta Control Panel 2024-11-21 6.1 Medium
Vesta v1.0.0-5 was discovered to contain a cross-site scripting (XSS) vulnerability via the body function at /web/api/v1/upload/UploadHandler.php.