Search vulnerabilities

Results 429,927

CVE-2022-22985

ICSA-22-062-01 IPCOMM ipDIO

The absence of filters when loading some sections in the web application of the vulnerable device allows attackers to inject malicious code that will be interpreted when a legitimate user accesses the specific web section where the information is displayed. Injection can be done on specific parameters. The injected code is executed when a legitimate user attempts to review history.

CVSS 3.1 · 8.8 High EPSS 1.0% KEV · Not listed
Vendors
CVE-2022-24915

ICSA-22-062-01 IPCOMM ipDIO

The absence of filters when loading some sections in the web application of the vulnerable device allows attackers to inject malicious code that will be interpreted when a legitimate user accesses the web section where the information is displayed. Injection can be done on specific parameters. The injected code is executed when a legitimate user attempts to upload, copy, download, or delete an existing configuration (Administrative Services).

CVSS 3.1 · 8 High EPSS 1.0% KEV · Not listed
Vendors
CVE-2020-25178

Rockwell Automation ISaGRAF5 Runtime Cleartext Transmission of Sensitive Information

ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Data is transferred over this protocol unencrypted, which could allow a remote unauthenticated attacker to upload, read, and delete files.

CVSS 3.1 · 7.5 High EPSS 1.7% KEV · Not listed
CVE-2020-25182

Rockwell Automation ISaGRAF5 Runtime Uncontrolled Search Path Element

Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code. This vulnerability only affects ISaGRAF Runtime when running on Microsoft Windows systems.

CVSS 3.1 · 6.7 Medium EPSS < 1% KEV · Not listed
CVE-2020-25176

Rockwell Automation ISaGRAF5 Runtime Relative Path Traversal

Some commands used by the Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x eXchange Layer (IXL) protocol perform various file operations in the file system. Since the parameter pointing to the file name is not checked for reserved characters, it is possible for a remote, unauthenticated attacker to traverse an application’s directory, which could lead to remote code execution.

CVSS 3.1 · 9.1 Critical EPSS 6.4% KEV · Not listed
CVE-2020-25184

Rockwell Automation ISaGRAF5 Runtime Unprotected Storage of Credentials

Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user passwords, resulting in information disclosure.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
CVE-2021-27430

GE UR family hardcoded credentials

GE UR bootloader binary Version 7.00, 7.01 and 7.02 included unused hardcoded credentials. Additionally, a user with physical access to the UR IED can interrupt the boot sequence by rebooting the UR.

CVSS 3.1 · 8.4 High EPSS < 1% KEV · Not listed
Vendors
Ge
CVE-2021-27471

Rockwell Automation Connected Components Workbench Path Traversal

The parsing mechanism that processes certain file types does not provide input sanitization for file paths. This may allow an attacker to craft malicious files that, when opened by Rockwell Automation Connected Components Workbench v12.00.00 and prior, can traverse the file system. If successfully exploited, an attacker could overwrite existing files and create additional files with the same permissions of the Connected Components Workbench software. User interaction is required for this exploit to be successful.

CVSS 3.1 · 7.7 High EPSS 2.9% KEV · Not listed
CVE-2021-27475

Rockwell Automation Connected Components Workbench Deserialization of Untrusted Data

Rockwell Automation Connected Components Workbench v12.00.00 and prior does not limit the objects that can be deserialized. This vulnerability allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in remote code execution. This vulnerability requires user interaction to be successfully exploited.

CVSS 3.1 · 8.6 High EPSS 3.0% KEV · Not listed
CVE-2021-44462

Horner Automation Cscape EnvisionRV Improper Input Validation

This vulnerability can be exploited by parsing maliciously crafted project files with Horner Automation Cscape EnvisionRV v4.50.3.1 and prior. The issues result from the lack of proper validation of user-supplied data, which can result in reads and writes past the end of allocated data structures. User interaction is required to exploit this vulnerability as an attacker must trick a valid user to open a malicious HMI project file.

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
CVE-2021-27501

Philips Vue PACS Improper Adherence to Coding Standards

Philips Vue PACS versions 12.2.x.x and prior does not follow certain coding rules for development, which can lead to resultant weaknesses or increase the severity of the associated vulnerabilities.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Products
Myvue Speech Vue Motion and 1 more
CVE-2021-33018

Philips Vue PACS Use of a Broken or Risky Cryptographic Algorithm

The use of a broken or risky cryptographic algorithm in Philips Vue PACS versions 12.2.x.x and prior is an unnecessary risk that may result in the exposure of sensitive information.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Products
Myvue Speech Vue Motion and 1 more
CVE-2022-1098

Delta Electronics DIAEnergie Uncontrolledly Search Path Element

Delta Electronics DIAEnergie (all versions prior to 1.8.02.004) are vulnerable to a DLL hijacking condition. When combined with the Incorrect Default Permissions vulnerability of 4.2.2 above, this makes it possible for an attacker to escalate privileges

CVSS 3.1 · 7.8 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2022-1159

Rockwell Automation Studio 5000 Logix Designer Code Injection

Rockwell Automation Studio 5000 Logix Designer (all versions) are vulnerable when an attacker who achieves administrator access on a workstation running Studio 5000 Logix Designer could inject controller code undetectable to a user.

CVSS 3.1 · 7.7 High EPSS 3.5% KEV · Not listed
CVE-2022-26417

Rockwell Automation Studio 5000 Logix Designer Use After Free

Omron CX-Position (versions 2.5.3 and prior) is vulnerable to a use after free memory condition while processing a specific project file, which may allow an attacker to execute arbitrary code.

CVSS 3.1 · 7.8 High EPSS 1.5% KEV · Not listed
Vendors
Products
CVE-2022-26022

Rockwell Automation Studio 5000 Logix Designer Out-of-Bounds Write

Omron CX-Position (versions 2.5.3 and prior) is vulnerable to an out-of-bounds write while processing a specific project file, which may allow an attacker to execute arbitrary code.

CVSS 3.1 · 7.8 High EPSS 1.5% KEV · Not listed
Vendors
Products
CVE-2022-26419

Rockwell Automation Studio 5000 Logix Designer Code Injection

Omron CX-Position (versions 2.5.3 and prior) is vulnerable to multiple stack-based buffer overflow conditions while parsing a specific project file, which may allow an attacker to locally execute arbitrary code.

CVSS 3.1 · 7.8 High EPSS 2.1% KEV · Not listed
Vendors
Products
CVE-2021-32977

AVEVA System Platform Improper Verification of Cryptographic Signature

AVEVA System Platform versions 2017 through 2020 R2 P01 does not verify, or incorrectly verifies, the cryptographic signature for data.

CVSS 3.1 · 7.2 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2021-32985

AVEVA System Platform Origin Validation Error

AVEVA System Platform versions 2017 through 2020 R2 P01 does not properly verify that the source of data or communication is valid.

CVSS 3.1 · 7.2 High EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2021-32981

AVEVA System Platform Path Traversal

AVEVA System Platform versions 2017 through 2020 R2 P01 uses external input to construct a pathname that is intended to identify a file or directory that is located underneath a restricted parent directory, but the software does not properly neutralize special elements within the pathname that can cause the pathname to resolve to a location that is outside of the restricted directory.

CVSS 3.1 · 7.2 High EPSS 1.2% KEV · Not listed
Vendors
Products