Search Results (323543 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2022-32792 2 Apple, Redhat 7 Ipados, Iphone Os, Macos and 4 more 2025-05-22 8.8 High
An out-of-bounds write issue was addressed with improved input validation. This issue is fixed in iOS 15.6 and iPadOS 15.6, watchOS 8.7, tvOS 15.6, macOS Monterey 12.5, Safari 15.6. Processing maliciously crafted web content may lead to arbitrary code execution.
CVE-2022-32790 1 Apple 6 Ipados, Iphone Os, Mac Os X and 3 more 2025-05-22 7.5 High
This issue was addressed with improved checks. This issue is fixed in tvOS 15.5, watchOS 8.6, iOS 15.5 and iPadOS 15.5, macOS Monterey 12.4, macOS Big Sur 11.6.6, Security Update 2022-004 Catalina. A remote user may be able to cause a denial-of-service.
CVE-2022-32789 1 Apple 1 Macos 2025-05-22 5.5 Medium
A logic issue was addressed with improved checks. This issue is fixed in macOS Monterey 12.5. An app may be able to bypass Privacy preferences.
CVE-2022-32787 1 Apple 6 Ipados, Iphone Os, Mac Os X and 3 more 2025-05-22 8.8 High
An out-of-bounds write issue was addressed with improved bounds checking. This issue is fixed in iOS 15.6 and iPadOS 15.6, macOS Big Sur 11.6.8, watchOS 8.7, tvOS 15.6, macOS Monterey 12.5, Security Update 2022-005 Catalina. Processing maliciously crafted web content may lead to arbitrary code execution.
CVE-2022-32786 1 Apple 2 Mac Os X, Macos 2025-05-22 5.5 Medium
An issue in the handling of environment variables was addressed with improved validation. This issue is fixed in Security Update 2022-005 Catalina, macOS Big Sur 11.6.8, macOS Monterey 12.5. An app may be able to modify protected parts of the file system.
CVE-2022-32785 1 Apple 4 Ipados, Iphone Os, Mac Os X and 1 more 2025-05-22 5.5 Medium
A null pointer dereference was addressed with improved validation. This issue is fixed in iOS 15.6 and iPadOS 15.6, Security Update 2022-005 Catalina, macOS Big Sur 11.6.8, macOS Monterey 12.5. Processing an image may lead to a denial-of-service.
CVE-2022-32783 1 Apple 1 Macos 2025-05-22 5.5 Medium
A logic issue was addressed with improved checks. This issue is fixed in macOS Monterey 12.4. An app may gain unauthorized access to Bluetooth.
CVE-2022-22423 2 Ibm, Linux 5 Aix, Common Cryptographic Architecture, I and 2 more 2025-05-22 5.5 Medium
IBM Common Cryptographic Architecture (CCA 5.x MTM for 4767 and CCA 7.x MTM for 4769) could allow a local user to cause a denial of service due to improper input validation. IBM X-Force ID: 223596.
CVE-2020-27252 1 Medtronic 2 Mycarelink Smart Model 25000, Mycarelink Smart Model 25000 Firmware 2025-05-22 8.8 High
Medtronic MyCareLink Smart 25000 is vulnerable to a race condition in the MCL Smart Patient Reader software update system, which allows unsigned firmware to be uploaded and executed on the Patient Reader. If exploited, an attacker could remotely execute code on the MCL Smart Patient Reader device, leading to control of the device.
CVE-2020-25187 1 Medtronic 2 Mycarelink Smart Model 25000, Mycarelink Smart Model 25000 Firmware 2025-05-22 8.8 High
Medtronic MyCareLink Smart 25000 is  vulnerable when an authenticated attacker runs a debug command, which can be sent to the patient reader and cause a heap overflow event within the MCL Smart Patient Reader software stack. The heap overflow could allow an attacker to remotely execute code on the MCL Smart Patient Reader, potentially leading to control of the device
CVE-2020-25183 1 Medtronic 2 Mycarelink Smart Model 25000, Mycarelink Smart Model 25000 Firmware 2025-05-22 8 High
Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader and the Medtronic MyCareLink Smart mobile app is vulnerable to bypass. This vulnerability enables an attacker to use another mobile device or malicious application on the patient’s smartphone to authenticate to the patient’s Medtronic Smart Reader, fooling the device into believing it is communicating with the original Medtronic smart phone application when executed within range of Bluetooth communication.
CVE-2019-6540 1 Medtronic 46 Amplia Crt-d, Amplia Crt-d Firmware, Carelink 2090 and 43 more 2025-05-22 6.5 Medium
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement encryption. An attacker with adjacent short-range access to a target product can listen to communications, including the transmission of sensitive data.
CVE-2019-6538 1 Medtronic 40 Amplia Crt-d, Amplia Crt-d Firmware, Carelink 2090 and 37 more 2025-05-22 9.3 Critical
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement authentication or authorization. An attacker with adjacent short-range access to an affected product, in situations where the product’s radio is turned on, can inject, replay, modify, and/or intercept data within the telemetry communication. This communication protocol provides the ability to read and write memory values to affected implanted cardiac devices; therefore, an attacker could exploit this communication protocol to change memory in the implanted cardiac device.
CVE-2003-5004 2025-05-22 N/A
** REJECT ** DO NOT USE THIS CANDIDATE NUMBER. Reason: This candidate was issued in error. Notes: All references and descriptions in this candidate have been removed to prevent accidental usage.
CVE-2025-47275 2025-05-22 9.1 Critical
Auth0-PHP provides the PHP SDK for Auth0 Authentication and Management APIs. Starting in version 8.0.0-BETA1 and prior to version 8.14.0, session cookies of applications using the Auth0-PHP SDK configured with CookieStore have authentication tags that can be brute forced, which may result in unauthorized access. Certain pre-conditions are required to be vulnerable to this issue: Applications using the Auth0-PHP SDK, or the Auth0/symfony, Auth0/laravel-auth0, and Auth0/wordpress SDKs that rely on the Auth0-PHP SDK; and session storage configured with CookieStore. Upgrade Auth0/Auth0-PHP to v8.14.0 to receive a patch. As an additional precautionary measure, rotating cookie encryption keys is recommended. Note that once updated, any previous session cookies will be rejected.
CVE-2022-2025 1 Grandstream 2 Gds3710, Gds3710 Firmware 2025-05-22 9.8 Critical
an attacker with knowledge of user/pass of Grandstream GSD3710 in its 1.0.11.13 version, could overflow the stack since it doesn't check the param length before use the strcopy instruction. The explotation of this vulnerability may lead an attacker to execute a shell with full access.
CVE-2022-40628 1 Tacitine 4 En6200-prime Quad-100, En6200-prime Quad-100 Firmware, En6200-prime Quad-35 and 1 more 2025-05-22 9.8 Critical
This vulnerability exists in Tacitine Firewall, all versions of EN6200-PRIME QUAD-35 and EN6200-PRIME QUAD-100 between 19.1.1 to 22.20.1 (inclusive), due to improper control of code generation in the Tacitine Firewall web-based management interface. An unauthenticated remote attacker could exploit this vulnerability by sending a specially crafted http request on the targeted device. Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to execute arbitrary commands on the targeted device.
CVE-2025-25500 1 Cosmwasm 1 Cosmwasm 2025-05-22 7.5 High
An issue in CosmWasm prior to v2.2.0 allows attackers to bypass capability restrictions in blockchains by exploiting a lack of runtime capability validation. This allows attackers to deploy a contract without capability enforcement, and execute unauthorized actions on the blockchain.
CVE-2025-30113 1 Hella 2 Dr 820, Dr 820 Firmware 2025-05-22 9.8 Critical
An issue was discovered on the Forvia Hella HELLA Driving Recorder DR 820. Hardcoded Credentials exist in the APK for Ports 9091 and 9092. The dashcam's Android application contains hardcoded credentials that allow unauthorized access to device settings through ports 9091 and 9092. These credentials, stored in cleartext, can be exploited by an attacker who gains access to the dashcam's network.
CVE-2025-30114 1 Hella 2 Dr 820, Dr 820 Firmware 2025-05-22 9.1 Critical
An issue was discovered on the Forvia Hella HELLA Driving Recorder DR 820. Bypassing of Device Pairing can occur. The pairing mechanism relies solely on the connecting device's MAC address. By obtaining the MAC address through network scanning and spoofing it, an attacker can bypass the authentication process and gain full access to the dashcam's features without proper authorization.