| A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The system images for installation or update of the affected application contain unit test scripts with sensitive information. An attacker could gain information about testing architecture and also tamper with test configuration. |
| A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application contains an older feature that allows to import device configurations via a specific endpoint. An attacker could use this vulnerability for information disclosure. |
| A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2). The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to unauthorized access to resources and potentially lead to code execution. |
| A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to low privileged users accessing privileged information. |
| A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to unauthorized access to limited information. |
| A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). A customized HTTP POST request could force the application to write the status of a given user to a log file, exposing sensitive user information that could provide valuable guidance to an attacker. |
| A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). Due to improper input validation, the OpenSSL certificate's password could be printed to a file reachable by an attacker. |
| A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). The application does not perform the integrity check of the update packages. Without validation, an admin user might be tricked to install a malicious package, granting root privileges to an attacker. |
| `Undici.ProxyAgent` never verifies the remote server's certificate, and always exposes all request & response data to the proxy. This unexpectedly means that proxies can MitM all HTTPS traffic, and if the proxy's URL is HTTP then it also means that nominally HTTPS requests are actually sent via plain-text HTTP between Undici and the proxy server. |
| In universal forwarder versions before 9.0, management services are available remotely by default. When not required, it introduces a potential exposure, but it is not a vulnerability. If exposed, we recommend each customer assess the potential severity specific to your environment. In 9.0, the universal forwarder now binds the management port to localhost preventing remote logins by default. If management services are not required in versions before 9.0, set disableDefaultPort = true in server.conf OR allowRemoteLogin = never in server.conf OR mgmtHostPort = localhost in web.conf. See Configure universal forwarder management security (https://docs.splunk.com/Documentation/Splunk/9.0.0/Security/EnableTLSCertHostnameValidation#Configure_universal_forwarder_management_security) for more information on disabling the remote management services. |
| In multiple CODESYS products, file download and upload function allows access to internal files in the working directory e.g. firmware files of the PLC. All requests are processed on the controller only if no level 1 password is configured on the controller or if remote attacker has previously successfully authenticated himself to the controller. A successful Attack may lead to a denial of service, change of local files, or drain of confidential Information. User interaction is not required |
| Multiple CODESYS Products are prone to a out-of bounds read or write access. A low privileged remote attacker may craft a request with invalid offset, which can cause an out-of-bounds read or write access, resulting in denial-of-service condition or local memory overwrite, which can lead to a change of local files. User interaction is not required. |
| Multiple CODESYS Products are prone to a buffer over read. A low privileged remote attacker may craft a request with an invalid offset, which can cause an internal buffer over-read, resulting in a denial-of-service condition. User interaction is not required. |
| Multiple CODESYS products are affected to a buffer overflow.A low privileged remote attacker may craft a request, which can cause a buffer copy without checking the size of the service, resulting in a denial-of-service condition. User Interaction is not required. |
| In multiple CODESYS products, a low privileged remote attacker may craft a request, which cause an out-of-bounds read, resulting in a denial-of-service condition. User Interaction is not required. |
| In multiple CODESYS products, a remote attacker may craft a request which may cause an unexpected sign extension, resulting in a denial-of-service condition or memory overwrite. |
| In multiple CODESYS products, a low privileged remote attacker may craft a request, which may cause a heap-based buffer overflow, resulting in a denial-of-service condition or memory overwrite. User interaction is not required. |
| In multiple CODESYS products, a low privileged remote attacker may craft a request that cause a read access to an uninitialized pointer, resulting in a denial-of-service. User interaction is not required. |
| Tenda AC10 US_AC10V1.0RTL_V15.03.06.26_multi_TD01 was discovered to contain a remote code execution (RCE) vulnerability via the lanIp parameter. |
| MERCURY MIPC451-4 1.0.22 Build 220105 Rel.55642n was discovered to contain a remote code execution (RCE) vulnerability which is exploitable via a crafted POST request. |