Search Results (360295 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2020-6983 1 Moxa 110 Pt-7528-12msc-12tx-4gsfp-hv, Pt-7528-12msc-12tx-4gsfp-hv-hv, Pt-7528-12msc-12tx-4gsfp-hv-hv Firmware and 107 more 2024-11-21 7.5 High
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a hard-coded cryptographic key, which increases the possibility that confidential data can be recovered.
CVE-2020-6982 1 Honeywell 1 Win-pak 2024-11-21 8.8 High
In Honeywell WIN-PAK 4.7.2, Web and prior versions, the header injection vulnerability has been identified, which may allow remote code execution.
CVE-2020-6981 1 Moxa 4 Eds-510e, Eds-510e Firmware, Eds-g516e and 1 more 2024-11-21 9.8 Critical
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, an attacker may gain access to the system without proper authentication.
CVE-2020-6980 1 Rockwellautomation 6 Micrologix 1100, Micrologix 1100 Firmware, Micrologix 1400 and 3 more 2024-11-21 3.3 Low
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, If Simple Mail Transfer Protocol (SMTP) account data is saved in RSLogix 500, a local attacker with access to a victim’s project may be able to gather SMTP server authentication data as it is written to the project file in cleartext.
CVE-2020-6979 1 Moxa 4 Eds-510e, Eds-510e Firmware, Eds-g516e and 1 more 2024-11-21 7.5 High
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, the affected products use a hard-coded cryptographic key, increasing the possibility that confidential data can be recovered.
CVE-2020-6978 1 Honeywell 1 Win-pak 2024-11-21 7.2 High
In Honeywell WIN-PAK 4.7.2, Web and prior versions, the affected product is vulnerable due to the usage of old jQuery libraries.
CVE-2020-6977 1 Ge 32 Invenia Abus Scan Station, Invenia Abus Scan Station Firmware, Logiq E10 and 29 more 2024-11-21 6.8 Medium
A restricted desktop environment escape vulnerability exists in the Kiosk Mode functionality of affected devices. Specially crafted inputs can allow the user to escape the restricted environment, resulting in access to the underlying operating system. Affected devices include the following GE Ultrasound Products: Vivid products - all versions; LOGIQ - all versions not including LOGIQ 100 Pro; Voluson - all versions; Versana Essential - all versions; Invenia ABUS Scan station - all versions; Venue - all versions not including Venue 40 R1-3 and Venue 50 R4-5
CVE-2020-6976 1 Deltaww 1 Cncsoft Screeneditor 2024-11-21 5.5 Medium
Delta Industrial Automation CNCSoft ScreenEditor, v1.00.96 and prior. An out-of-bounds read overflow can be exploited when a valid user opens a specially crafted, malicious input file due to the lack of validation.
CVE-2020-6975 1 Digi 3 Connectport Lts 32 Mei, Connectport Lts 32 Mei Bios, Connectport Lts 32 Mei Firmware 2024-11-21 4.9 Medium
Digi International ConnectPort LTS 32 MEI, Firmware Version 1.4.3 (82002228_K 08/09/2018), bios Version 1.2. Successful exploitation of this vulnerability could allow an attacker to upload a malicious file to the application.
CVE-2020-6974 1 Honeywell 1 Notifier Webserver 2024-11-21 9.8 Critical
Honeywell Notifier Web Server (NWS) Version 3.50 is vulnerable to a path traversal attack, which allows an attacker to bypass access to restricted directories. Honeywell has released a firmware update to address the problem.
CVE-2020-6973 1 Digi 3 Connectport Lts 32 Mei, Connectport Lts 32 Mei Bios, Connectport Lts 32 Mei Firmware 2024-11-21 6.2 Medium
Digi International ConnectPort LTS 32 MEI, Firmware Version 1.4.3 (82002228_K 08/09/2018), bios Version 1.2. Multiple cross-site scripting vulnerabilities exist that could allow an attacker to cause a denial-of-service condition.
CVE-2020-6972 1 Honeywell 1 Notifier Webserver 2024-11-21 9.1 Critical
In Notifier Web Server (NWS) Version 3.50 and earlier, the Honeywell Fire Web Server’s authentication may be bypassed by a capture-replay attack from a web browser.
CVE-2020-6971 1 Emerson 1 Valvelink 2024-11-21 7.8 High
In Emerson ValveLink v12.0.264 to v13.4.118, a vulnerability in the ValveLink software may allow a local, unprivileged, trusted insider to escalate privileges due to insecure configuration parameters.
CVE-2020-6970 1 Emerson 1 Openenterprise Scada Server 2024-11-21 9.8 Critical
A Heap-based Buffer Overflow was found in Emerson OpenEnterprise SCADA Server 2.83 (if Modbus or ROC Interfaces have been installed and are in use) and all versions of OpenEnterprise 3.1 through 3.3.3, where a specially crafted script could execute code on the OpenEnterprise Server.
CVE-2020-6969 1 Automationdirect 22 C-more Ea9-rhi, C-more Ea9-rhi Firmware, C-more Ea9-t10cl and 19 more 2024-11-21 9.8 Critical
It is possible to unmask credentials and other sensitive information on “unprotected” project files, which may allow an attacker to remotely access the C-More Touch Panels EA9 series: firmware versions prior to 6.53 and manipulate system configurations.
CVE-2020-6968 1 Honeywell 2 Inncom Inncontrol, Inncom Inncontrol Firmware 2024-11-21 7.8 High
Honeywell INNCOM INNControl 3 allows workstation users to escalate application user privileges through the modification of local configuration files.
CVE-2020-6967 1 Rockwellautomation 1 Factorytalk Services Platform 2024-11-21 9.8 Critical
In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data.
CVE-2020-6966 1 Gehealthcare 12 Apexpro Telemetry Server, Apexpro Telemetry Server Firmware, Carescape Central Station Mai700 and 9 more 2024-11-21 10.0 Critical
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilize a weak encryption scheme for remote desktop control, which may allow an attacker to obtain remote code execution of devices on the network.
CVE-2020-6965 1 Gehealthcare 18 Apexpro Telemetry Server, Apexpro Telemetry Server Firmware, Carescape B450 Monitor and 15 more 2024-11-21 9.9 Critical
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, a vulnerability in the software update mechanism allows an authenticated attacker to upload arbitrary files on the system through a crafted update package.
CVE-2020-6964 1 Gehealthcare 12 Apexpro Telemetry Server, Apexpro Telemetry Server Firmware, Carescape Central Station Mai700 and 9 more 2024-11-21 8.6 High
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X and CARESCAPE Central Station (CSCS) Versions 2.X, the integrated service for keyboard switching of the affected devices could allow attackers to obtain remote keyboard input access without authentication over the network.