Search Results (361971 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2021-27432 1 Opcfoundation 2 Ua-.net-legacy, Ua .net Standard Stack 2024-11-21 7.5 High
OPC Foundation UA .NET Standard versions prior to 1.4.365.48 and OPC UA .NET Legacy are vulnerable to an uncontrolled recursion, which may allow an attacker to trigger a stack overflow.
CVE-2021-27429 1 Ti 14 Cc3200, Cc3220r, Cc3220s and 11 more 2024-11-21 7.4 High
Texas Instruments TI-RTOS returns a valid pointer to a small buffer on extremely large values. This can trigger an integer overflow vulnerability in 'HeapTrack_alloc' and result in code execution.
CVE-2021-27413 1 Omron 2 Cx-one, Cx-server 2024-11-21 7.8 High
Omron CX-One Versions 4.60 and prior, including CX-Server Versions 5.0.29.0 and prior, are vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.
CVE-2021-27412 1 Deltaww 1 Dopsoft 2024-11-21 7.8 High
Delta Electronics DOPSoft Versions 4.0.10.17 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code.
CVE-2021-27410 1 Hillrom 9 Connex Central Station, Connex Device Integration Suite Network Connectivity Engine, Connex Integrated Wall System and 6 more 2024-11-21 9.8 Critical
The affected product is vulnerable to an out-of-bounds write, which may result in corruption of data or code execution on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).
CVE-2021-27408 1 Hillrom 9 Connex Central Station, Connex Device Integration Suite Network Connectivity Engine, Connex Integrated Wall System and 6 more 2024-11-21 7.5 High
The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).
CVE-2021-27405 1 Scrapbox-parser Project 1 Scrapbox-parser 2024-11-21 7.5 High
A ReDoS (regular expression denial of service) flaw was found in the @progfay/scrapbox-parser package before 6.0.3 for Node.js.
CVE-2021-27404 1 Asus 2 Askey Rtf8115vw, Askey Rtf8115vw Firmware 2024-11-21 6.1 Medium
Askey RTF8115VW BR_SV_g11.11_RTF_TEF001_V6.54_V014 devices allow injection of a Host HTTP header.
CVE-2021-27403 1 Asus 2 Askey Rtf8115vw, Askey Rtf8115vw Firmware 2024-11-21 6.1 Medium
Askey RTF8115VW BR_SV_g11.11_RTF_TEF001_V6.54_V014 devices allow cgi-bin/te_acceso_router.cgi curWebPage XSS.
CVE-2021-27402 1 Mitel 1 Micollab 2024-11-21 6.5 Medium
The SAS Admin portal of Mitel MiCollab before 9.2 FP2 could allow an unauthenticated attacker to access (view and modify) user data by injecting arbitrary directory paths due to improper URL validation, aka Directory Traversal.
CVE-2021-27401 1 Mitel 1 Micollab 2024-11-21 6.1 Medium
The Join Meeting page of Mitel MiCollab Web Client before 9.2 FP2 could allow an attacker to access (view and modify) user data by executing arbitrary code due to insufficient input validation, aka Cross-Site Scripting (XSS).
CVE-2021-27400 1 Hashicorp 1 Vault 2024-11-21 7.5 High
HashiCorp Vault and Vault Enterprise Cassandra integrations (storage backend and database secrets engine plugin) did not validate TLS certificates when connecting to Cassandra clusters. Fixed in 1.6.4 and 1.7.1
CVE-2021-27399 1 Siemens 1 Simcenter Femap 2024-11-21 7.8 High
A vulnerability has been identified in Simcenter Femap 2020.2 (All versions < V2020.2.MP3), Simcenter Femap 2021.1 (All versions < V2021.1.MP3). The femap.exe application lacks proper validation of user-supplied data when parsing FEMAP files. This could result in an out of bounds write past the end of an allocated structure, a different vulnerability than CVE-2021-27387. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12820)
CVE-2021-27398 1 Siemens 1 Tecnomatix Plant Simulation 2024-11-21 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a stack based buffer overflow, a different vulnerability than CVE-2021-27396. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13290)
CVE-2021-27397 1 Siemens 1 Tecnomatix Plant Simulation 2024-11-21 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a memory corruption condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13287)
CVE-2021-27396 1 Siemens 1 Tecnomatix Plant Simulation 2024-11-21 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V16.0.5). The PlantSimCore.dll library lacks proper validation of user-supplied data when parsing SPP files. This could result in a stack based buffer overflow, a different vulnerability than CVE-2021-27398. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13279)
CVE-2021-27395 1 Siemens 4 Simatic Process Historian 2013, Simatic Process Historian 2014, Simatic Process Historian 2019 and 1 more 2024-11-21 8.1 High
A vulnerability has been identified in SIMATIC Process Historian 2013 and earlier (All versions), SIMATIC Process Historian 2014 (All versions < SP3 Update 6), SIMATIC Process Historian 2019 (All versions), SIMATIC Process Historian 2020 (All versions). An interface in the software that is used for critical functionalities lacks authentication, which could allow a malicious user to maliciously insert, modify or delete data.
CVE-2021-27394 1 Mendix 1 Mendix 2024-11-21 8.8 High
A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.19), Mendix Applications using Mendix 8 (All versions < V8.17.0), Mendix Applications using Mendix 8 (V8.12) (All versions < V8.12.5), Mendix Applications using Mendix 8 (V8.6) (All versions < V8.6.9), Mendix Applications using Mendix 9 (All versions < V9.0.5). Authenticated, non-administrative users could modify their privileges by manipulating the user role under certain circumstances, allowing them to gain administrative privileges.
CVE-2021-27393 1 Siemens 3 Nucleus Net, Nucleus Readystart V3, Nucleus Source Code 2024-11-21 5.3 Medium
A vulnerability has been identified in Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2013.08), Nucleus Source Code (Versions including affected DNS modules). The DNS client does not properly randomize UDP port numbers of DNS requests. That could allow an attacker to poison the DNS cache or spoof DNS resolving.
CVE-2021-27392 1 Siemens 1 Siveillance Video Open Network Bridge 2024-11-21 8.8 High
A vulnerability has been identified in Siveillance Video Open Network Bridge (2020 R3), Siveillance Video Open Network Bridge (2020 R2), Siveillance Video Open Network Bridge (2020 R1), Siveillance Video Open Network Bridge (2019 R3), Siveillance Video Open Network Bridge (2019 R2), Siveillance Video Open Network Bridge (2019 R1), Siveillance Video Open Network Bridge (2018 R3), Siveillance Video Open Network Bridge (2018 R2). Affected Open Network Bridges store user credentials for the authentication between ONVIF clients and ONVIF server using a hard-coded key. The encrypted credentials can be retrieved via the MIP SDK. This could allow an authenticated remote attacker to retrieve and decrypt all credentials stored on the ONVIF server.