| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| This CVE ID has been rejected or withdrawn by its CVE Numbering Authority. |
| This CVE ID has been rejected or withdrawn by its CVE Numbering Authority. |
| This CVE ID has been rejected or withdrawn by its CVE Numbering Authority. |
| In several functions of SettingsState.java, there is a possible system crash loop due to resource exhaustion. This could lead to local denial of service with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-10 Android-11 Android-12 Android-12L Android-13Android ID: A-239415861 |
| In Mfc_Transceive of phNxpExtns_MifareStd.cpp, there is a possible out of bounds write due to a missing bounds check. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-10Android ID: A-241387741 |
| In getTrampolineIntent of SettingsActivity.java, there is a possible launch of arbitrary activity due to an Intent mismatch in the code. This could lead to local escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-12L Android-13Android ID: A-246300272 |
| TOTOlink A7100RU V7.4cu.2313_B20191024 was discovered to contain a command injection vulnerability via the username parameter in the setting/setOpenVpnCertGenerationCfg function. |
| In AutomaticZenRule of AutomaticZenRule.java, there is a possible persistent DoS due to resource exhaustion. This could lead to local denial of service with no additional execution privileges needed. User interaction is not needed for exploitation.Product: AndroidVersions: Android-10 Android-11 Android-12 Android-12L Android-13Android ID: A-243794204 |
| In Ruckus R310 10.5.1.0.199, Ruckus R500 10.5.1.0.199, Ruckus R600 10.5.1.0.199, Ruckus T300 10.5.1.0.199, Ruckus T301n 10.5.1.0.199, Ruckus T301s 10.5.1.0.199, SmartCell Gateway 200 (SCG200) before 3.6.2.0.795, SmartZone 100 (SZ-100) before 3.6.2.0.795, SmartZone 300 (SZ300) before 3.6.2.0.795, Virtual SmartZone (vSZ) before 3.6.2.0.795, ZoneDirector 1100 9.10.2.0.130, ZoneDirector 1200 10.2.1.0.218, ZoneDirector 3000 10.2.1.0.218, ZoneDirector 5000 10.0.1.0.151, a vulnerability allows attackers to switch completely to unauthorized image to be Boot as primary verified image. |
| The Login with Phone Number WordPress Plugin, version < 1.4.2, is affected by an authenticated SQL injection vulnerability in the 'ID' parameter of its 'lwp_forgot_password' action. |
| The Quick Event Manager WordPress Plugin, version < 9.7.5, is affected by a reflected cross-site scripting vulnerability in the 'category' parameter of its 'qem_ajax_calendar' action. |
| The Survey Maker WordPress Plugin, version < 3.1.2, is affected by an authenticated SQL injection vulnerability in the 'surveys_ids' parameter of its 'ays_surveys_export_json' action. |
| The Easy Digital Downloads WordPress Plugin, versions 3.1.0.2 & 3.1.0.3, is affected by an unauthenticated SQL injection vulnerability in the 's' parameter of its 'edd_download_search' action. |
| The Paid Memberships Pro WordPress Plugin, version < 2.9.8, is affected by an unauthenticated SQL injection vulnerability in the 'code' parameter of the '/pmpro/v1/order' REST route. |
| Cross-site scripting vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote authenticated attacker to inject an arbitrary script and obtain the sensitive information. |
| CX-Motion-MCH v2.32 and earlier contains an access of uninitialized pointer vulnerability. Having a user to open a specially crafted project file may lead to information disclosure and/or arbitrary code execution. |
| Improper access control vulnerability in CONPROSYS HMI System (CHS) Ver.3.4.5 and earlier allows a remote unauthenticated attacker to bypass access restriction and obtain the server certificate including the private key of the product. |
| A privilege escalation vulnerability exists in Delta Electronics InfraSuite Device Master 00.00.02a. A default user 'User', which is in the 'Read Only User' group, can view the password of another default user 'Administrator', which is in the 'Administrator' group. This allows any lower privileged user to log in as an administrator. |
| A malicious / defective bluetooth controller can cause buffer overreads in the most functions that process HCI command responses. |
| Rapid7 Velociraptor did not properly sanitize the client ID parameter to the CreateCollection API, allowing a directory traversal in where the collection task could be written. It was possible to provide a client id of "../clients/server" to schedule the collection for the server (as a server artifact), but only require privileges to schedule collections on the client.
Normally, to schedule an artifact on the server, the COLLECT_SERVER permission is required. This permission is normally only granted to "administrator" role. Due to this issue, it is sufficient to have the COLLECT_CLIENT privilege, which is normally granted to the "investigator" role.
To exploit this vulnerability, the attacker must already have a Velociraptor user account at least "investigator" level, and be able to authenticate to the GUI and issue an API call to the backend. Typically, most users deploy Velociraptor with limited access to a trusted group, and most users will already be administrators within the GUI.
This issue affects Velociraptor versions before 0.6.7-5. Version 0.6.7-5, released January 16, 2023, fixes the issue.
|