Search Results (357822 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2022-22818 4 Debian, Djangoproject, Fedoraproject and 1 more 6 Debian Linux, Django, Fedora and 3 more 2024-11-21 6.1 Medium
The {% debug %} template tag in Django 2.2 before 2.2.27, 3.2 before 3.2.12, and 4.0 before 4.0.2 does not properly encode the current context. This may lead to XSS.
CVE-2022-22817 3 Debian, Python, Redhat 5 Debian Linux, Pillow, Enterprise Linux and 2 more 2024-11-21 9.8 Critical
PIL.ImageMath.eval in Pillow before 9.0.0 allows evaluation of arbitrary expressions, such as ones that use the Python exec method. A lambda expression could also be used.
CVE-2022-22816 3 Debian, Python, Redhat 5 Debian Linux, Pillow, Enterprise Linux and 2 more 2024-11-21 6.5 Medium
path_getbbox in path.c in Pillow before 9.0.0 has a buffer over-read during initialization of ImagePath.Path.
CVE-2022-22815 3 Debian, Python, Redhat 3 Debian Linux, Pillow, Enterprise Linux 2024-11-21 6.5 Medium
path_getbbox in path.c in Pillow before 9.0.0 improperly initializes ImagePath.Path.
CVE-2022-22814 1 Asus 1 Myasus 2024-11-21 9.8 Critical
The System Diagnosis service of MyASUS before 3.1.2.0 allows privilege escalation.
CVE-2022-22813 1 Schneider-electric 66 Easergy P141, Easergy P141 Firmware, Easergy P142 and 63 more 2024-11-21 9.8 Critical
A CWE-798: Use of Hard-coded Credentials vulnerability exists. If an attacker were to obtain the TLS cryptographic key and take active control of the Courier tunneling communication network, they could potentially observe and manipulate traffic associated with product configuration.
CVE-2022-22812 1 Schneider-electric 6 Fellerlynk, Fellerlynk Firmware, Spacelynk and 3 more 2024-11-21 6.1 Medium
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a web session compromise when an attacker injects and then executes arbitrary malicious JavaScript code inside the target browser. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)
CVE-2022-22811 1 Schneider-electric 6 Fellerlynk, Fellerlynk Firmware, Spacelynk and 3 more 2024-11-21 8.1 High
A CWE-352: Cross-Site Request Forgery (CSRF) vulnerability exists that could induce users to perform unintended actions, leading to the override of the system�s configurations when an attacker persuades a user to visit a rogue website. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)
CVE-2022-22810 1 Schneider-electric 6 Fellerlynk, Fellerlynk Firmware, Spacelynk and 3 more 2024-11-21 9.8 Critical
A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to manipulate the admin after numerous attempts at guessing credentials. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)
CVE-2022-22809 1 Schneider-electric 6 Fellerlynk, Fellerlynk Firmware, Spacelynk and 3 more 2024-11-21 5.3 Medium
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)
CVE-2022-22808 1 Schneider-electric 14 Hmibscea53d1edb, Hmibscea53d1edb Firmware, Hmibscea53d1edl and 11 more 2024-11-21 8.8 High
A CWE-352: Cross-Site Request Forgery (CSRF) exists that could cause a remote attacker to gain unauthorized access to the product when conducting cross-domain attacks based on same-origin policy or cross-site request forgery protections bypass. Affected Product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)
CVE-2022-22807 1 Schneider-electric 14 Hmibscea53d1edb, Hmibscea53d1edb Firmware, Hmibscea53d1edl and 11 more 2024-11-21 7.4 High
A CWE-1021 Improper Restriction of Rendered UI Layers or Frames vulnerability exists that could cause unintended modifications of the product settings or user accounts when deceiving the user to use the web interface rendered within iframes. Affected Product: EcoStruxure EV Charging Expert (formerly known as EVlink Load Management System): (HMIBSCEA53D1EDB, HMIBSCEA53D1EDS, HMIBSCEA53D1EDM, HMIBSCEA53D1EDL, HMIBSCEA53D1ESS, HMIBSCEA53D1ESM, HMIBSCEA53D1EML) (All Versions prior to SP8 (Version 01) V4.0.0.13)
CVE-2022-22806 1 Schneider-electric 16 Scl Series 1029 Ups, Scl Series 1029 Ups Firmware, Scl Series 1030 Ups and 13 more 2024-11-21 9.8 Critical
A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
CVE-2022-22805 1 Schneider-electric 16 Scl Series 1029 Ups, Scl Series 1029 Ups Firmware, Scl Series 1030 Ups and 13 more 2024-11-21 9.8 Critical
A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperly handled TLS packet is reassembled. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)
CVE-2022-22804 1 Schneider-electric 1 Ecostruxure Power Monitoring Expert 2024-11-21 5.4 Medium
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could allow an authenticated attacker to view data, change settings, or impact availability of the software when the user visits a page containing the injected payload. Affected Product: EcoStruxure Power Monitoring Expert (Versions 2020 and prior)
CVE-2022-22798 1 Sysaid 1 Sysaid 2024-11-21 6.8 Medium
Sysaid – Pro Plus Edition, SysAid Help Desk Broken Access Control v20.4.74 b10, v22.1.20 b62, v22.1.30 b49 - An attacker needs to log in as a guest after that the system redirects him to the service portal or EndUserPortal.JSP, then he needs to change the path in the URL to /ConcurrentLogin%2ejsp after that he will receive an error message with a login button, by clicking on it, he will connect to the system dashboard. The attacker can receive sensitive data like server details, usernames, workstations, etc. He can also perform actions such as uploading files, deleting calls from the system.
CVE-2022-22797 1 Sysaid 1 Sysaid 2024-11-21 4.6 Medium
Sysaid – sysaid Open Redirect - An Attacker can change the redirect link at the parameter "redirectURL" from"GET" request from the url location: /CommunitySSORedirect.jsp?redirectURL=https://google.com. Unvalidated redirects and forwards are possible when a web application accepts untrusted input that could cause the web application to redirect the request to a URL contained within untrusted input. By modifying untrusted URL input to a malicious site, an attacker may successfully launch a phishing scam and steal user credentials.
CVE-2022-22796 1 Sysaid 1 Sysaid 2024-11-21 7 High
Sysaid – Sysaid System Takeover - An attacker can bypass the authentication process by accessing to: /wmiwizard.jsp, Then to: /ConcurrentLogin.jsp, then click on the login button, and it will redirect you to /home.jsp without any authentication.
CVE-2022-22795 1 Signiant 1 Manager\+agents 2024-11-21 6.8 Medium
Signiant - Manager+Agents XML External Entity (XXE) - Extract internal files of the affected machine An attacker can read all the system files, the product is running with root on Linux systems and nt/authority on windows systems, which allows him to access and extract any file on the systems, such as passwd, shadow, hosts and so on. By gaining access to these files, attackers can steal sensitive information from the victims machine.
CVE-2022-22794 1 Cybonet 1 Pineapp Mail Secure 2024-11-21 6.8 Medium
Cybonet - PineApp Mail Relay Unauthenticated Sql Injection. Attacker can send a request to: /manage/emailrichment/userlist.php?CUSTOMER_ID_INNER=1 /admin/emailrichment/userlist.php?CUSTOMER_ID_INNER=1 /manage/emailrichment/usersunlist.php?CUSTOMER_ID_INNER=1 /admin/emailrichment/usersunlist.php?CUSTOMER_ID_INNER=1 and by doing that, the attacker can run Remote Code Execution in one liner.