| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A security issue was discovered in Kubernetes where a user may be able to redirect pod traffic to private networks on a Node. Kubernetes already prevents creation of Endpoint IPs in the localhost or link-local range, but the same validation was not performed on EndpointSlice IPs. |
| A security issue was discovered in kube-apiserver that could allow node updates to bypass a Validating Admission Webhook. Clusters are only affected by this vulnerability if they run a Validating Admission Webhook for Nodes that denies admission based at least partially on the old state of the Node object. Validating Admission Webhook does not observe some previous fields. |
| The fUSBHub driver in the PCoIP Software Client prior to version 21.07.0 had an error in object management during the handling of a variety of IOCTLs, which allowed an attacker to cause a denial of service. |
| The OpenSSL component of the Teradici PCoIP Software Client prior to version 21.07.0 was compiled without the no-autoload-config option, which allowed an attacker to elevate to the privileges of the running process via placing a specially crafted dll in a build configuration directory. |
| The OpenSSL component of the Teradici PCoIP Standard Agent prior to version 21.07.0 was compiled without the no-autoload-config option, which allowed an attacker to elevate to the privileges of the running process via placing a specially crafted dll in a build configuration directory. |
| The USB vHub in the Teradici PCOIP Software Agent prior to version 21.07.0 would accept commands from any program, which may allow an attacker to elevate privileges by changing the flow of program execution within the vHub driver. |
| Teradici PCoIP Graphics Agent for Windows prior to 21.03 does not validate NVENC.dll. An attacker could replace the .dll and redirect pixels elsewhere. |
| An attacker may cause a Denial of Service (DoS) in multiple versions of Teradici PCoIP Agent via a null pointer dereference. |
| Sensitive smart card data is logged in default INFO logs by Teradici's PCoIP Connection Manager and Security Gateway prior to version 21.01.3. |
| A null pointer dereference in Teradici PCoIP Soft Client versions prior to 20.07.3 could allow an attacker to crash the software. |
| An out of bounds write in Teradici PCoIP soft client versions prior to version 20.10.1 could allow an attacker to remotely execute code. |
| Under certain conditions, Teradici PCoIP Agents for Windows prior to version 20.10.0 and Teradici PCoIP Agents for Linux prior to version 21.01.0 may log parts of a user's password in the application logs. |
| It was discovered that the get_starttime() function in data/apport did not properly parse the /proc/pid/stat file from the kernel. |
| It was discovered that the get_pid_info() function in data/apport did not properly parse the /proc/pid/status file from the kernel. |
| AdTran Personal Phone Manager 10.8.1 software is vulnerable to an issue that allows for exfiltration of data over DNS. This could allow for exposed AdTran Personal Phone Manager web servers to be used as DNS redirectors to tunnel arbitrary data over DNS. NOTE: The affected appliances NetVanta 7060 and NetVanta 7100 are considered End of Life and as such this issue will not be patched |
| The AdTran Personal Phone Manager software is vulnerable to multiple reflected cross-site scripting (XSS) issues. These issues impact at minimum versions 10.8.1 and below but potentially impact later versions as well since they have not previously been disclosed. Only version 10.8.1 was able to be confirmed during primary research. NOTE: The affected appliances NetVanta 7060 and NetVanta 7100 are considered End of Life and as such this issue will not be patched |
| The AdTran Personal Phone Manager software is vulnerable to an authenticated stored cross-site scripting (XSS) issues. These issues impact at minimum versions 10.8.1 and below but potentially impact later versions as well since they have not previously been disclosed. Only version 10.8.1 was able to be confirmed during primary research. NOTE: The affected appliances NetVanta 7060 and NetVanta 7100 are considered End of Life and as such this issue will not be patched |
| A vulnerability has been identified in Solid Edge SE2020 (All versions < SE2020MP13), Solid Edge SE2020 (All versions < SE2020MP14), Solid Edge SE2021 (All Versions < SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12529) |
| A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions >= V0.5.0.0 < V1.0.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS client does not properly randomize DNS transaction IDs. That could allow an attacker to poison the DNS cache or spoof DNS resolving. |
| A vulnerability has been identified in RUGGEDCOM RM1224 (V6.3), SCALANCE M-800 (V6.3), SCALANCE S615 (V6.3), SCALANCE SC-600 (All Versions >= V2.1 and < V2.1.3). Multiple failed SSH authentication attempts could trigger a temporary Denial-of-Service under certain conditions. When triggered, the device will reboot automatically. |