| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| OX App Suite through 7.10.3 allows SSRF because GET requests are sent to arbitrary domain names with an initial autoconfig. substring. |
| The Chamber Dashboard Business Directory plugin 3.2.8 for WordPress allows XSS. |
| An issue was discovered in PowerDNS Authoritative through 4.3.0 when --enable-experimental-gss-tsig is used. A remote, unauthenticated attacker might be able to cause a double-free, leading to a crash or possibly arbitrary code execution. by sending crafted queries with a GSS-TSIG signature. |
| An issue was discovered in PowerDNS Authoritative through 4.3.0 when --enable-experimental-gss-tsig is used. A remote, unauthenticated attacker can cause a denial of service by sending crafted queries with a GSS-TSIG signature. |
| An issue was discovered in PowerDNS Authoritative through 4.3.0 when --enable-experimental-gss-tsig is used. A remote, unauthenticated attacker can trigger a race condition leading to a crash, or possibly arbitrary code execution, by sending crafted queries with a GSS-TSIG signature. |
| The Ignite portal in Mitel MiContact Center Business before 9.3.0.0 could allow a local attacker to view system information due to insufficient output sanitization. |
| The Ignite portal in Mitel MiContact Center Business before 9.3.0.0 could allow an attacker to execute arbitrary scripts due to insufficient input validation, aka XSS. A successful exploit could allow an attacker to gain access to a user session. |
| The vulnerabilities can be exploited to cause the web visualization component of the PLC to stop and not respond, leading to genuine users losing remote visibility of the PLC state. If a user attempts to login to the PLC while this vulnerability is exploited, the PLC will show an error state and refuse connections to Automation Builder. The execution of the PLC application is not affected by this vulnerability. This issue affects ABB AC500 V2 products with onboard Ethernet. |
| An unauthenticated specially crafted packet sent by an attacker over the network will cause a denial-of-service (DoS) vulnerability. Vulnerability allows attacker to stop the PLC. After stopping (ERR LED flashing red), physical access to the PLC is required in order to restart the application. This issue affects: ABB AC500 V2 products with onboard Ethernet version 2.8.4 and prior versions. |
| The affected versions of S+ Operations (version 2.1 SP1 and earlier) used an approach for user authentication which relies on validation at the client node (client-side authentication). This is not as secure as having the server validate a client application before allowing a connection. Therefore, if the network communication or endpoints for these applications are not protected, unauthorized actors can bypass authentication and make unauthorized connections to the server application. |
| In S+ Operations and S+ Historian, the passwords of internal users (not Windows Users) are encrypted but improperly stored in a database. |
| A S+ Operations and S+ Historian service is subject to a DoS by special crafted messages. An attacker might use this flaw to make it crash or even execute arbitrary code on the machine where the service is hosted. |
| An authenticated user might execute malicious code under the user context and take control of the system. S+ Operations or S+ Historian database is affected by multiple vulnerabilities such as the possibility to allow remote authenticated users to gain high privileges. |
| Vulnerabilities in the S+ Operations and S+ Historian web applications can lead to a possible code execution and privilege escalation, redirect the user somewhere else or download unwanted data. |
| In Symphony Plus Operations and Symphony Plus Historian, some services can be vulnerable to privilege escalation attacks. An unprivileged (but authenticated) user could execute arbitrary code and result in privilege escalation, depending on the user that the service runs as. |
| In S+ Operations and S+ History, it is possible that an unauthenticated user could inject values to the Operations History server (or standalone S+ History server) and ultimately write values to the controlled process. |
| In S+ Operations and S+ Historian, not all client commands correctly check user permission as expected. Authenticated but Unauthorized remote users could execute a Denial-of-Service (DoS) attack, execute arbitrary code, or obtain more privilege than intended on the machines. |
| In S+ Operations and S+ Historian, a successful SQL injection exploit can read sensitive data from the database, modify database data (Insert/Update/Delete), execute administration operations on the database (such as shutdown the DBMS), recover the content of a given file present on the DBMS file system and in some cases issue commands to the operating system. This can lead to a loss of confidentiality and data integrity or even affect the product behavior and its availability. |
| A vulnerability in Base Software for SoftControl allows an attacker to insert and run arbitrary code in a computer running the affected product. This issue affects: . |
| Trace Financial CRESTBridge <6.3.0.02 contains an authenticated SQL injection vulnerability, which was fixed in 6.3.0.03. |