Search Results (372505 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-31338 2026-04-15 N/A
A missing authorization vulnerability in the retrieve teacher Information function of Wisdom Master Pro versions 5.0 through 5.2 allows remote attackers to obtain partial user data by accessing the API functionality.
CVE-2025-31340 2026-04-15 N/A
A improper control of filename for include/require statement in PHP program vulnerability in the retrieve course Information function of Wisdom Master Pro versions 5.0 through 5.2 allows remote attackers to perform arbitrary system commands by running a malicious file.
CVE-2024-53843 1 Cloud Native Computing Foundation 1 Keycloak-connector 2026-04-15 8.1 High
@dapperduckling/keycloak-connector-server is an opinionated series of libraries for Node.js applications and frontend clients to interface with keycloak. A Reflected Cross-Site Scripting (XSS) vulnerability was discovered in the authentication flow of the application. This issue arises due to improper sanitization of the URL parameters, allowing the URL bar's contents to be injected and reflected into the HTML page. An attacker could craft a malicious URL to execute arbitrary JavaScript in the browser of a victim who visits the link. Any application utilizing this authentication library is vulnerable. Users of the application are at risk if they can be lured into clicking on a crafted malicious link. The vulnerability has been patched in version 2.5.5 by ensuring proper sanitization and escaping of user input in the affected URL parameters. Users are strongly encouraged to upgrade. If upgrading is not immediately possible, users can implement the following workarounds: 1. Employ a Web Application Firewall (WAF) to block malicious requests containing suspicious URL parameters. or 2. Apply input validation and escaping directly within the application’s middleware or reverse proxy layer, specifically targeting the affected parameters.
CVE-2024-53930 2026-04-15 6.1 Medium
WikiDocs before 1.0.65 allows stored XSS by authenticated users via data that comes after $$\\, which is mishandled by a KaTeX parser.
CVE-2025-61984 1 Openbsd 1 Openssh 2026-04-15 3.6 Low
ssh in OpenSSH before 10.1 allows control characters in usernames that originate from certain possibly untrusted sources, potentially leading to code execution when a ProxyCommand is used. The untrusted sources are the command line and %-sequence expansion of a configuration file. (A configuration file that provides a complete literal username is not categorized as an untrusted source.)
CVE-2025-31713 2026-04-15 8.4 High
In engineer mode service, there is a possible command injection due to improper input validation. This could lead to local escalation of privilege with no additional execution privileges needed.
CVE-2024-28607 2026-04-15 2.9 Low
The ip-utils package through 2.4.0 for Node.js might allow SSRF because some IP addresses (such as 0x7f.1) are improperly categorized as globally routable via a falsy isPrivate return value.
CVE-2025-62413 1 Emqx 1 Mqttx 2026-04-15 6.1 Medium
MQTTX is an MQTT 5.0 desktop client and MQTT testing tool. A Cross-Site Scripting (XSS) vulnerability was introduced in MQTTX v1.12.0 due to improper handling of MQTT message payload rendering. Malicious payloads containing HTML or JavaScript could be rendered directly in the MQTTX message viewer. If exploited, this could allow attackers to execute arbitrary scripts in the context of the application UI — for example, attempting to access MQTT connection credentials or trigger unintended actions through script injection. This vulnerability is especially relevant when MQTTX is used with brokers in untrusted or multi-tenant environments, where message content cannot be fully controlled. This vulnerability is fixed in 1.12.1.
CVE-2025-62427 1 Angular 1 Angular 2026-04-15 N/A
The Angular SSR is a server-rise rendering tool for Angular applications. The vulnerability is a Server-Side Request Forgery (SSRF) flaw within the URL resolution mechanism of Angular's Server-Side Rendering package (@angular/ssr) before 19.2.18, 20.3.6, and 21.0.0-next.8. The function createRequestUrl uses the native URL constructor. When an incoming request path (e.g., originalUrl or url) begins with a double forward slash (//) or backslash (\\), the URL constructor treats it as a schema-relative URL. This behavior overrides the security-intended base URL (protocol, host, and port) supplied as the second argument, instead resolving the URL against the scheme of the base URL but adopting the attacker-controlled hostname. This allows an attacker to specify an external domain in the URL path, tricking the Angular SSR environment into setting the page's virtual location (accessible via DOCUMENT or PlatformLocation tokens) to this attacker-controlled domain. Any subsequent relative HTTP requests made during the SSR process (e.g., using HttpClient.get('assets/data.json')) will be incorrectly resolved against the attacker's domain, forcing the server to communicate with an arbitrary external endpoint. This vulnerability is fixed in 19.2.18, 20.3.6, and 21.0.0-next.8.
CVE-2025-31929 2026-04-15 4.2 Medium
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions), UL Resi High End 40A w/15118 Hw (8EM1312-4CF18-0FA3) (All versions), UL Resi High End 48A w/15118 Hw (8EM1312-5CF18-0FA3) (All versions), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions). Affected devices do not contain an Immutable Root of Trust in M0 Hardware. An attacker with physical access to the device could use this to execute arbitrary code.
CVE-2025-31930 2026-04-15 8.8 High
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
CVE-2025-31944 1 Intel 1 Tdx Module 2026-04-15 5.3 Medium
Race condition for some TDX Module before version tdx1.5 within Ring 0: Hypervisor may allow a denial of service. Authorized adversary with a privileged user combined with a high complexity attack may enable denial of service. This result may potentially occur via local access when attack requirements are present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (none), integrity (none) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (low) impacts.
CVE-2025-31946 2026-04-15 6.2 Medium
Pixmeo OsiriX MD is vulnerable to a local use after free scenario, which could allow an attacker to locally import a crafted DICOM file and cause memory corruption or a system crash.
CVE-2025-64444 1 Sony 1 Ncp-hg100 2026-04-15 N/A
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in NCP-HG100 1.4.48.16 and earlier. If exploited, a remote attacker who has obtained the authentication information to log in to the management page of the product may execute an arbitrary OS command with root privileges.
CVE-2025-31971 2026-04-15 5.1 Medium
AIML Solutions for HCL SX is vulnerable to a URL validation vulnerability.  The issue may allow attackers to launch a server-side request forgery (SSRF) attack enabling unauthorized network calls from the system, potentially exposing internal services or sensitive information.
CVE-2024-36053 1 Linuxmint 1 Mintupload 2026-04-15 9 Critical
In the mintupload package through 4.2.0 for Linux Mint, service-name mishandling leads to command injection via shell metacharacters in check_connection, drop_data_received_cb, and Service.remove. A user can modify a service name in a ~/.linuxmint/mintUpload/services/service file.
CVE-2019-25237 2026-04-15 9.8 Critical
V-SOL GPON/EPON OLT Platform v2.03 contains a privilege escalation vulnerability that allows normal users to gain administrative access by manipulating the user role parameter. Attackers can send a crafted HTTP POST request to the user management endpoint with 'user_role_mod' set to integer value '1' to elevate their privileges.
CVE-2023-4855 2026-04-15 7.2 High
A command injection vulnerability was identified in SMM/SMM2 and FPC that could allow an authenticated user with elevated privileges to execute unauthorized commands via IPMI.
CVE-2025-6493 1 Codemirror 1 Codemirror 2026-04-15 5.3 Medium
A weakness has been identified in CodeMirror up to 5.65.20. Affected is an unknown function of the file mode/markdown/markdown.js of the component Markdown Mode. This manipulation causes inefficient regular expression complexity. It is possible to initiate the attack remotely. The exploit has been made available to the public and could be exploited. Upgrading to version 6.0 is able to address this issue. You should upgrade the affected component. Not all code samples mentioned in the GitHub issue can be found. The repository mentions, that "CodeMirror 6 exists, and is [...] much more actively maintained."
CVE-2019-25238 2026-04-15 4.3 Medium
V-SOL GPON/EPON OLT Platform 2.03 contains a cross-site request forgery vulnerability that allows attackers to perform administrative actions without user consent. Attackers can craft malicious web pages to create admin users, enable SSH, or modify system settings by tricking authenticated administrators into loading a specially crafted page.