Search Results (372505 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-42845 1 Invesalius 1 Invesalius 2026-04-15 8 High
An eval Injection vulnerability in the component invesalius/reader/dicom.py of InVesalius 3.1.99991 through 3.1.99998 allows attackers to execute arbitrary code via loading a crafted DICOM file.
CVE-2024-42852 1 Microfocus 1 Acutoweb 2026-04-15 6.1 Medium
Cross Site Scripting vulnerability in AcuToWeb server v.10.5.0.7577C8b allows a remote attacker to execute arbitrary code via the index.php component.
CVE-2024-28607 2026-04-15 2.9 Low
The ip-utils package through 2.4.0 for Node.js might allow SSRF because some IP addresses (such as 0x7f.1) are improperly categorized as globally routable via a falsy isPrivate return value.
CVE-2025-62413 1 Emqx 1 Mqttx 2026-04-15 6.1 Medium
MQTTX is an MQTT 5.0 desktop client and MQTT testing tool. A Cross-Site Scripting (XSS) vulnerability was introduced in MQTTX v1.12.0 due to improper handling of MQTT message payload rendering. Malicious payloads containing HTML or JavaScript could be rendered directly in the MQTTX message viewer. If exploited, this could allow attackers to execute arbitrary scripts in the context of the application UI — for example, attempting to access MQTT connection credentials or trigger unintended actions through script injection. This vulnerability is especially relevant when MQTTX is used with brokers in untrusted or multi-tenant environments, where message content cannot be fully controlled. This vulnerability is fixed in 1.12.1.
CVE-2024-43235 2026-04-15 7.1 High
Missing Authorization vulnerability in MetaBox.Io Meta Box – WordPress Custom Fields Framework allows Exploiting Incorrectly Configured Access Control Security Levels.This issue affects Meta Box – WordPress Custom Fields Framework: from n/a through 5.9.10.
CVE-2024-43794 2026-04-15 6.1 Medium
OpenSearch Dashboards Security Plugin adds a configuration management UI for the OpenSearch Security features to OpenSearch Dashboards. Improper validation of the nextUrl parameter can lead to external redirect on login to OpenSearch-Dashboards for specially crafted parameters. A patch is available in 1.3.19 and 2.16.0 for this issue.
CVE-2025-62427 1 Angular 1 Angular 2026-04-15 N/A
The Angular SSR is a server-rise rendering tool for Angular applications. The vulnerability is a Server-Side Request Forgery (SSRF) flaw within the URL resolution mechanism of Angular's Server-Side Rendering package (@angular/ssr) before 19.2.18, 20.3.6, and 21.0.0-next.8. The function createRequestUrl uses the native URL constructor. When an incoming request path (e.g., originalUrl or url) begins with a double forward slash (//) or backslash (\\), the URL constructor treats it as a schema-relative URL. This behavior overrides the security-intended base URL (protocol, host, and port) supplied as the second argument, instead resolving the URL against the scheme of the base URL but adopting the attacker-controlled hostname. This allows an attacker to specify an external domain in the URL path, tricking the Angular SSR environment into setting the page's virtual location (accessible via DOCUMENT or PlatformLocation tokens) to this attacker-controlled domain. Any subsequent relative HTTP requests made during the SSR process (e.g., using HttpClient.get('assets/data.json')) will be incorrectly resolved against the attacker's domain, forcing the server to communicate with an arbitrary external endpoint. This vulnerability is fixed in 19.2.18, 20.3.6, and 21.0.0-next.8.
CVE-2025-31929 2026-04-15 4.2 Medium
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions), UL Resi High End 40A w/15118 Hw (8EM1312-4CF18-0FA3) (All versions), UL Resi High End 48A w/15118 Hw (8EM1312-5CF18-0FA3) (All versions), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions). Affected devices do not contain an Immutable Root of Trust in M0 Hardware. An attacker with physical access to the device could use this to execute arbitrary code.
CVE-2024-46622 2026-04-15 9.8 Critical
An Escalation of Privilege security vulnerability was found in SecureAge Security Suite software 7.0.x before 7.0.38, 7.1.x before 7.1.11, 8.0.x before 8.0.18, and 8.1.x before 8.1.18 that allows arbitrary file creation, modification and deletion.
CVE-2025-31930 2026-04-15 8.8 High
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
CVE-2025-31944 1 Intel 1 Tdx Module 2026-04-15 5.3 Medium
Race condition for some TDX Module before version tdx1.5 within Ring 0: Hypervisor may allow a denial of service. Authorized adversary with a privileged user combined with a high complexity attack may enable denial of service. This result may potentially occur via local access when attack requirements are present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (none), integrity (none) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (low) impacts.
CVE-2025-31946 2026-04-15 6.2 Medium
Pixmeo OsiriX MD is vulnerable to a local use after free scenario, which could allow an attacker to locally import a crafted DICOM file and cause memory corruption or a system crash.
CVE-2024-48396 1 Sohelamin 1 Chatbot 2026-04-15 6.1 Medium
AIML Chatbot 1.0 (fixed in 2.0) is vulnerable to Cross Site Scripting (XSS). The vulnerability is exploited through the message input field, where attackers can inject malicious HTML or JavaScript code. The chatbot fails to sanitize these inputs, leading to the execution of malicious scripts.
CVE-2024-48450 1 Hcengineering 1 Huly 2026-04-15 6.5 Medium
An arbitrary file upload vulnerability in Huly Platform v0.6.295 allows attackers to execute arbitrary code via uploading a crafted HTML file into chat group.
CVE-2024-48455 2026-04-15 2.7 Low
An issue in Netis Wifi6 Router NX10 2.0.1.3643 and 2.0.1.3582 and Netis Wifi 11AC Router NC65 3.0.0.3749 and Netis Wifi 11AC Router NC63 3.0.0.3327 and 3.0.0.3503 and Netis Wifi 11AC Router NC21 3.0.0.3800, 3.0.0.3500 and 3.0.0.3329 and Netis Wifi Router MW5360 1.0.1.3442 and 1.0.1.3031 allows a remote attacker to obtain sensitive information via the mode_name, wl_link parameters of the skk_get.cgi component.
CVE-2024-48459 1 Tenda 1 Ax2 Pro Firmware 2026-04-15 7.3 High
A command execution vulnerability exists in the AX2 Pro home router produced by Shenzhen Tenda Technology Co., Ltd. (Jixiang Tenda) v.DI_7003G-19.12.24A1V16.03.29.50;V16.03.29.50;V16.03.29.50. An attacker can exploit this vulnerability by constructing a malicious payload to execute commands and further obtain shell access to the router's file system with the highest privileges.
CVE-2024-48852 2026-04-15 9.4 Critical
Insertion of Sensitive Information into Log File vulnerability observed in FLEXON. Some information may be improperly disclosed through https access. This issue affects FLXEON through <= 9.3.4.
CVE-2024-49378 1 Zimocode 1 Smartup 2026-04-15 6.1 Medium
smartUp, a web browser mouse gestures extension, has a universal cross-site scripting issue in the Edge and Firefox versions of smartUp 7.2.622.1170. The vulnerability allows another extension to execute arbitrary code in the context of the user’s tab. As of time of publication, no known patches exist.
CVE-2025-64444 1 Sony 1 Ncp-hg100 2026-04-15 N/A
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in NCP-HG100 1.4.48.16 and earlier. If exploited, a remote attacker who has obtained the authentication information to log in to the management page of the product may execute an arbitrary OS command with root privileges.
CVE-2025-31971 2026-04-15 5.1 Medium
AIML Solutions for HCL SX is vulnerable to a URL validation vulnerability.  The issue may allow attackers to launch a server-side request forgery (SSRF) attack enabling unauthorized network calls from the system, potentially exposing internal services or sensitive information.