Search Results (324358 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2018-4843 1 Siemens 22 Simatic Cp 343-1, Simatic Cp 343-1 Firmware, Simatic Cp 443-1 and 19 more 2024-11-21 6.5 Medium
A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC CP 343-1 (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 Advanced (All versions < V3.3), SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions < V3.2.16), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V1.7.0), SIMATIC S7-1500 Software Controller (All versions < V1.7.0), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions < V3.3.16), SIMATIC S7-300 CPU 315-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 319-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions < V3.2.16), SIMATIC S7-400 CPU 412-2 PN V7 (All versions < V7.0.3), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.9), SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.7), SIMATIC S7-410 CPU family (incl. SIPLUS variants) (All versions < V8.1), SIMATIC WinAC RTX 2010 (All versions < V2010 SP3), SIMATIC WinAC RTX F 2010 (All versions < V2010 SP3), SINUMERIK 828D (All versions < V4.7 SP6 HF1), SIPLUS ET 200S IM151-8 PN/DP CPU (All versions < V3.2.16), SIPLUS ET 200S IM151-8F PN/DP CPU (All versions < V3.2.16), SIPLUS NET CP 443-1 (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (All versions < V3.3), SIPLUS S7-300 CPU 314C-2 PN/DP (All versions < V3.3.16), SIPLUS S7-300 CPU 315-2 PN/DP (All versions < V3.2.16), SIPLUS S7-300 CPU 315F-2 PN/DP (All versions < V3.2.16), SIPLUS S7-300 CPU 317-2 PN/DP (All versions < V3.2.16), SIPLUS S7-300 CPU 317F-2 PN/DP (All versions < V3.2.16), SIPLUS S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIPLUS S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), Softnet PROFINET IO for PC-based Windows systems (All versions). Responding to a PROFINET DCP request with a specially crafted PROFINET DCP packet could cause a denial of service condition of the requesting system. The security vulnerability could be exploited by an attacker located on the same Ethernet segment (OSI Layer 2) as the targeted device. A manual restart is required to recover the system.
CVE-2018-4842 1 Siemens 6 Scalance X200, Scalance X200 Firmware, Scalance X200 Irt and 3 more 2024-11-21 N/A
A vulnerability has been identified in SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). A remote, authenticated attacker with access to the configuration web server could be able to store script code on the web site, if the HRP redundancy option is set. This code could be executed in the web browser of victims visiting this web site (XSS), affecting its confidentiality, integrity and availability. User interaction is required for successful exploitation, as the user needs to visit the manipulated web site. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.
CVE-2018-4841 1 Siemens 2 Tim 1531 Irc, Tim 1531 Irc Firmware 2024-11-21 9.8 Critical
A vulnerability has been identified in TIM 1531 IRC (All versions < V1.1). A remote attacker with network access to port 80/tcp or port 443/tcp could perform administrative operations on the device without prior authentication. Successful exploitation could allow to cause a denial-of-service, or read and manipulate data as well as configuration settings of the affected device. At the stage of publishing this security advisory no public exploitation is known. Siemens provides mitigations to resolve it.
CVE-2018-4840 1 Siemens 17 Digsi 4, En100 Ethernet Module Dnp3, En100 Ethernet Module Dnp3 Firmware and 14 more 2024-11-21 N/A
A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The device engineering mechanism allows an unauthenticated remote user to upload a modified device configuration overwriting access authorization passwords.
CVE-2018-4839 1 Siemens 17 Digsi 4, En100 Ethernet Module Dnp3, En100 Ethernet Module Dnp3 Firmware and 14 more 2024-11-21 N/A
A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions), Other SIPROTEC 4 relays (All versions), Other SIPROTEC Compact relays (All versions), SIPROTEC 4 7SD80 (All versions < V4.70), SIPROTEC 4 7SJ61 (All versions < V4.96), SIPROTEC 4 7SJ62 (All versions < V4.96), SIPROTEC 4 7SJ64 (All versions < V4.96), SIPROTEC 4 7SJ66 (All versions < V4.30), SIPROTEC Compact 7SJ80 (All versions < V4.77), SIPROTEC Compact 7SK80 (All versions < V4.77). An attacker with local access to the engineering system or in a privileged network position and able to obtain certain network traffic could possibly reconstruct access authorization passwords.
CVE-2018-4838 1 Siemens 10 En100 Ethernet Module Dnp3, En100 Ethernet Module Dnp3 Firmware, En100 Ethernet Module Iec 104 and 7 more 2024-11-21 N/A
A vulnerability has been identified in EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module DNP3 variant (All versions < V1.04), EN100 Ethernet module PROFINET IO variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions < V1.22). The web interface (TCP/80) of affected devices allows an unauthenticated user to upgrade or downgrade the firmware of the device, including to older versions with known vulnerabilities.
CVE-2018-4837 1 Siemens 1 Telecontrol Server Basic 2024-11-21 N/A
A vulnerability has been identified in TeleControl Server Basic < V3.1. An attacker with access to the TeleControl Server Basic's webserver (port 80/tcp or 443/tcp) could cause a Denial-of-Service condition on the web server. The remaining functionality of the TeleControl Server Basic is not affected by the Denial-of-Service condition.
CVE-2018-4836 1 Siemens 1 Telecontrol Server Basic 2024-11-21 N/A
A vulnerability has been identified in TeleControl Server Basic < V3.1. An authenticated attacker with a low-privileged account to the TeleControl Server Basic's port 8000/tcp could escalate his privileges and perform administrative operations.
CVE-2018-4835 1 Siemens 1 Telecontrol Server Basic 2024-11-21 N/A
A vulnerability has been identified in TeleControl Server Basic < V3.1. An attacker with network access to the TeleControl Server Basic's port 8000/tcp could bypass the authentication mechanism and read limited information.
CVE-2018-4834 1 Siemens 10 Pxc001-e.d, Pxc001-e.d Firmware, Pxc00\/50\/100\/200-e.d and 7 more 2024-11-21 9.8 Critical
A vulnerability has been identified in Desigo PXC00-E.D V4.10 (All versions < V4.10.111), Desigo PXC00-E.D V5.00 (All versions < V5.0.171), Desigo PXC00-E.D V5.10 (All versions < V5.10.69), Desigo PXC00-E.D V6.00 (All versions < V6.0.204), Desigo PXC00/64/128-U V4.10 (All versions < V4.10.111 only with web module), Desigo PXC00/64/128-U V5.00 (All versions < V5.0.171 only with web module), Desigo PXC00/64/128-U V5.10 (All versions < V5.10.69 only with web module), Desigo PXC00/64/128-U V6.00 (All versions < V6.0.204 only with web module), Desigo PXC001-E.D V4.10 (All versions < V4.10.111), Desigo PXC001-E.D V5.00 (All versions < V5.0.171), Desigo PXC001-E.D V5.10 (All versions < V5.10.69), Desigo PXC001-E.D V6.00 (All versions < V6.0.204), Desigo PXC100-E.D V4.10 (All versions < V4.10.111), Desigo PXC100-E.D V5.00 (All versions < V5.0.171), Desigo PXC100-E.D V5.10 (All versions < V5.10.69), Desigo PXC100-E.D V6.00 (All versions < V6.0.204), Desigo PXC12-E.D V4.10 (All versions < V4.10.111), Desigo PXC12-E.D V5.00 (All versions < V5.0.171), Desigo PXC12-E.D V5.10 (All versions < V5.10.69), Desigo PXC12-E.D V6.00 (All versions < V6.0.204), Desigo PXC200-E.D V4.10 (All versions < V4.10.111), Desigo PXC200-E.D V5.00 (All versions < V5.0.171), Desigo PXC200-E.D V5.10 (All versions < V5.10.69), Desigo PXC200-E.D V6.00 (All versions < V6.0.204), Desigo PXC22-E.D V4.10 (All versions < V4.10.111), Desigo PXC22-E.D V5.00 (All versions < V5.0.171), Desigo PXC22-E.D V5.10 (All versions < V5.10.69), Desigo PXC22-E.D V6.00 (All versions < V6.0.204), Desigo PXC22.1-E.D V4.10 (All versions < V4.10.111), Desigo PXC22.1-E.D V5.00 (All versions < V5.0.171), Desigo PXC22.1-E.D V5.10 (All versions < V5.10.69), Desigo PXC22.1-E.D V6.00 (All versions < V6.0.204), Desigo PXC36.1-E.D V4.10 (All versions < V4.10.111), Desigo PXC36.1-E.D V5.00 (All versions < V5.0.171), Desigo PXC36.1-E.D V5.10 (All versions < V5.10.69), Desigo PXC36.1-E.D V6.00 (All versions < V6.0.204), Desigo PXC50-E.D V4.10 (All versions < V4.10.111), Desigo PXC50-E.D V5.00 (All versions < V5.0.171), Desigo PXC50-E.D V5.10 (All versions < V5.10.69), Desigo PXC50-E.D V6.00 (All versions < V6.0.204), Desigo PXM20-E V4.10 (All versions < V4.10.111), Desigo PXM20-E V5.00 (All versions < V5.0.171), Desigo PXM20-E V5.10 (All versions < V5.10.69), Desigo PXM20-E V6.00 (All versions < V6.0.204). A remote attacker with network access to the device could potentially upload a new firmware image to the devices without prior authentication.
CVE-2018-4833 1 Siemens 18 Rfid 181-eip, Rfid 181-eip Firmware, Ruggedcom Wimax and 15 more 2024-11-21 N/A
A vulnerability has been identified in RFID 181EIP (All versions), RUGGEDCOM Win (V4.4, V4.5, V5.0, and V5.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.3), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.6), SCALANCE X-300 switch family (incl. SIPLUS NET variants) (All versions < V4.1.3), SCALANCE X408 (All versions < V4.1.3), SCALANCE X414 (All versions), SIMATIC RF182C (All versions). Unprivileged remote attackers located in the same local network segment (OSI Layer 2) could gain remote code execution on the affected products by sending a specially crafted DHCP response to a client's DHCP request.
CVE-2018-4832 1 Siemens 9 Openpcs 7, Simatic Batch, Simatic Net Pc and 6 more 2024-11-21 7.5 High
A vulnerability has been identified in OpenPCS 7 V7.1 and earlier (All versions), OpenPCS 7 V8.0 (All versions), OpenPCS 7 V8.1 (All versions < V8.1 Upd5), OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd1), SIMATIC BATCH V7.1 and earlier (All versions), SIMATIC BATCH V8.0 (All versions < V8.0 SP1 Upd21), SIMATIC BATCH V8.1 (All versions < V8.1 SP1 Upd16), SIMATIC BATCH V8.2 (All versions < V8.2 Upd10), SIMATIC BATCH V9.0 (All versions < V9.0 SP1), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions < 15 SP1), SIMATIC PCS 7 V7.1 and earlier (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP1), SIMATIC Route Control V7.1 and earlier (All versions), SIMATIC Route Control V8.0 (All versions), SIMATIC Route Control V8.1 (All versions), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions < V9.0 Upd1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Upd2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Upd5), SIMATIC WinCC V7.2 and earlier (All versions < WinCC 7.2 Upd 15), SIMATIC WinCC V7.3 (All versions < WinCC 7.3 Upd 16), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 4), SPPA-T3000 Application Server (All versions < Service Pack R8.2 SP2). Specially crafted messages sent to the RPC service of the affected products could cause a Denial-of-Service condition on the remote and local communication functionality of the affected products. A reboot of the system is required to recover the remote and local communication functionality. Please note that an attacker needs to have network access to the Application Server in order to exploit this vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2018-4478 1 Apple 1 Mac Os X 2024-11-21 6.8 Medium
A validation issue was addressed with improved logic. This issue is fixed in macOS High Sierra 10.13.5, Security Update 2018-003 Sierra, Security Update 2018-003 El Capitan. An attacker with physical access to a device may be able to elevate privileges.
CVE-2018-4474 1 Apple 6 Icloud, Iphone Os, Itunes and 3 more 2024-11-21 7.5 High
A memory consumption issue was addressed with improved memory handling. This issue is fixed in iCloud for Windows 7.7, watchOS 5, Safari 12, iOS 12, iTunes 12.9 for Windows, tvOS 12. Unexpected interaction causes an ASSERT failure.
CVE-2018-4470 1 Apple 1 Mac Os X 2024-11-21 N/A
A privacy issue in the handling of Open Directory records was addressed with improved indexing. This issue affected versions prior to macOS High Sierra 10.13.6.
CVE-2018-4468 1 Apple 1 Mac Os X 2024-11-21 5.5 Medium
This issue was addressed by removing additional entitlements. This issue is fixed in macOS Mojave 10.14.1, Security Update 2018-002 High Sierra, Security Update 2018-005 Sierra. A malicious application may be able to access restricted files.
CVE-2018-4467 1 Apple 1 Mac Os X 2024-11-21 7.8 High
A memory corruption issue was addressed with improved state management. This issue is fixed in macOS Mojave 10.14.3, Security Update 2019-001 High Sierra, Security Update 2019-001 Sierra, macOS Mojave 10.14.2, Security Update 2018-003 High Sierra, Security Update 2018-006 Sierra. A malicious application may be able to elevate privileges.
CVE-2018-4465 1 Apple 2 Iphone Os, Mac Os X 2024-11-21 N/A
A memory corruption issue was addressed with improved memory handling. This issue affected versions prior to iOS 12.1.1, macOS Mojave 10.14.2, tvOS 12.1.1, watchOS 5.1.2.
CVE-2018-4464 2 Apple, Microsoft 7 Icloud, Iphone Os, Itunes and 4 more 2024-11-21 N/A
Multiple memory corruption issues were addressed with improved memory handling. This issue affected versions prior to iOS 12.1.1, tvOS 12.1.1, watchOS 5.1.2, Safari 12.0.2, iTunes 12.9.2 for Windows, iCloud for Windows 7.9.
CVE-2018-4463 1 Apple 1 Mac Os X 2024-11-21 N/A
A memory corruption issue was addressed with improved memory handling. This issue affected versions prior to macOS Mojave 10.14.2.