| In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states. |
| In Omron CX-Supervisor Versions 3.30 and prior, use after free vulnerabilities can be exploited when CX Supervisor parses a specially crafted project file. |
| An improper access control vulnerability has been identified in Geutebruck G-Cam/EFD-2250 Version 1.12.0.4 and Topline TopFD-2125 Version 3.15.1 IP cameras, which could allow a full configuration download, including passwords. |
| In Omron CX-Supervisor Versions 3.30 and prior, parsing malformed project files may cause a heap-based buffer overflow. |
| In TotalAlert Web Application in BeaconMedaes Scroll Medical Air Systems prior to v4107600010.23, an attacker with network access to the integrated web server could retrieve default or user defined credentials stored and transmitted in an insecure manner. |
| In Omron CX-Supervisor Versions 3.30 and prior, parsing malformed project files may cause an out of bounds vulnerability. |
| A server-side request forgery vulnerability has been identified in Geutebruck G-Cam/EFD-2250 Version 1.12.0.4 and Topline TopFD-2125 Version 3.15.1 IP cameras, which could lead to proxied network scans. |
| In Omron CX-Supervisor Versions 3.30 and prior, access of uninitialized pointer vulnerabilities can be exploited when CX Supervisor indirectly calls an initialized pointer when parsing malformed packets. |
| Parsing malformed project files in Omron CX-One versions 4.42 and prior, including the following applications: CX-FLnet versions 1.00 and prior, CX-Protocol versions 1.992 and prior, CX-Programmer versions 9.65 and prior, CX-Server versions 5.0.22 and prior, Network Configurator versions 3.63 and prior, and Switch Box Utility versions 1.68 and prior, may cause a stack-based buffer overflow. |
| In Omron CX-Supervisor Versions 3.30 and prior, parsing malformed project files may cause a stack-based buffer overflow. |
| A cross-site scripting vulnerability has been identified in Geutebruck G-Cam/EFD-2250 Version 1.12.0.4 and Topline TopFD-2125 Version 3.15.1 IP cameras, which may allow remote code execution. |
| In Eaton ELCSoft versions 2.04.02 and prior, there are multiple cases where specially crafted files could cause a buffer overflow which, in turn, may allow remote execution of arbitrary code. |
| In the web application in BeaconMedaes TotalAlert Scroll Medical Air Systems running software versions prior to 4107600010.23, passwords are presented in plaintext in a file that is accessible without authentication. |
| WPLSoft in Delta Electronics versions 2.45.0 and prior writes data from a file outside the bounds of the intended buffer space, which could cause memory corruption or may allow remote code execution. |
| A Cross-site Scripting issue was discovered in OSIsoft PI Web API versions 2017 R2 and prior. Cross-site scripting may occur when input is incorrectly neutralized. |
| WPLSoft in Delta Electronics versions 2.45.0 and prior utilizes a fixed length heap buffer where a value larger than the buffer can be read from a file into the buffer, causing the buffer to be overwritten, which may allow remote code execution or cause the application to crash. |
| The private key of the web server in Moxa MXview versions 2.8 and prior is able to be read and accessed via an HTTP GET request, which may allow a remote attacker to decrypt encrypted information. |
| In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, a TFTP application has unrestricted file uploads to the web application without authorization, which may allow an attacker to execute arbitrary code. |
| A Protection Mechanism Failure issue was discovered in OSIsoft PI Vision versions 2017 and prior. The X-XSS-Protection response header is not set to block, allowing attempts at reflected cross-site scripting. |
| In Advantech WebAccess versions V8.2_20170817 and prior, WebAccess versions V8.3.0 and prior, WebAccess Dashboard versions V.2.0.15 and prior, WebAccess Scada Node versions prior to 8.3.1, and WebAccess/NMS 2.0.3 and prior, a path transversal vulnerability has been identified, which may allow an attacker to disclose sensitive information on the target. |