| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue was discovered in Ceph through 13.2.9. A POST request with an invalid tagging XML can crash the RGW process by triggering a NULL pointer exception. |
| Several XSS vulnerabilities in osCommerce CE Phoenix before 1.0.6.0 allow an attacker to inject and execute arbitrary JavaScript code. The malicious code can be injected as follows: the page parameter to catalog/admin/order_status.php, catalog/admin/tax_rates.php, catalog/admin/languages.php, catalog/admin/countries.php, catalog/admin/tax_classes.php, catalog/admin/reviews.php, or catalog/admin/zones.php; or the zpage or spage parameter to catalog/admin/geo_zones.php. |
| The Catch Breadcrumb plugin before 1.5.4 for WordPress allows Reflected XSS via the s parameter (a search query). Also affected are 16 themes (if the plugin is enabled) by the same author: Alchemist and Alchemist PRO, Izabel and Izabel PRO, Chique and Chique PRO, Clean Enterprise and Clean Enterprise PRO, Bold Photography PRO, Intuitive PRO, Devotepress PRO, Clean Blocks PRO, Foodoholic PRO, Catch Mag PRO, Catch Wedding PRO, and Higher Education PRO. |
| In Unisys Stealth 3.4.x, 4.x and 5.x before 5.0.026, if certificate-based authorization is used without HTTPS, an endpoint could be authorized without a private key. |
| Grafana version < 6.7.3 is vulnerable for annotation popup XSS. |
| The CentralAuth extension through REL1_34 for MediaWiki allows remote attackers to obtain sensitive hidden account information via an api.php?action=query&meta=globaluserinfo&guiuser= request. In other words, the information can be retrieved via the action API even though access would be denied when simply visiting wiki/Special:CentralAuth in a web browser. |
| SQLiteODBC 0.9996, as packaged for certain Linux distributions as 0.9996-4, has a race condition leading to root privilege escalation because any user can replace a /tmp/sqliteodbc$$ file with new contents that cause loading of an arbitrary library. |
| An issue was discovered in dbus >= 1.3.0 before 1.12.18. The DBusServer in libdbus, as used in dbus-daemon, leaks file descriptors when a message exceeds the per-message file descriptor limit. A local attacker with access to the D-Bus system bus or another system service's private AF_UNIX socket could use this to make the system service reach its file descriptor limit, denying service to subsequent D-Bus clients. |
| Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption (e.g., TLS/SSL) when transmitting treatment and prescription data on the network between the Phoenix system and the Exalis dialysis data management tool. An attacker with access to the network could observe sensitive treatment and prescription data sent between the Phoenix system and the Exalis tool. |
| The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an FTP service with hard-coded credentials. |
| Opto 22 SoftPAC Project Version 9.6 and prior. SoftPAC’s firmware files’ signatures are not verified upon firmware update. This allows an attacker to replace legitimate firmware files with malicious files. |
| The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials. |
| The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for wireless networking the FTP service operating on the WBM remains operational until the WBM is rebooted. |
| Opto 22 SoftPAC Project Version 9.6 and prior. Paths specified within the zip files used to update the SoftPAC firmware are not sanitized. As a result, an attacker with user privileges can gain arbitrary file write access with system access. |
| The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) telnet Command-Line Interface, grants access to sensitive data stored on the WBM that permits temporary configuration changes to network settings of the WBM, and allows the WBM to be rebooted. Temporary configuration changes to network settings are removed upon reboot. |
| Sigma Spectrum Infusion System v's6.x (model 35700BAX) and Baxter Spectrum Infusion System Version(s) 8.x (model 35700BAX2) at the application layer uses an unauthenticated clear-text communication channel to send and receive system status and operational data. This could allow an attacker that has circumvented network security measures to view sensitive non-private data or to perform a man-in-the-middle attack. |
| Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration values, network configuration of Sigma Spectrum WBM if installed. |
| Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser COM object, leading to denial-of-service conditions. |
| Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device. |
| Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device. |