| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue was discovered in the MULTIDOTS Advance Search for WooCommerce plugin 1.0.9 and earlier for WordPress. This plugin is vulnerable to a stored Cross-site scripting (XSS) vulnerability. A non-authenticated user can save the plugin settings and inject malicious JavaScript code in the Custom CSS textarea field, which will be loaded on every site page. |
| The MULTIDOTS WooCommerce Quick Reports plugin 1.0.6 and earlier for WordPress is vulnerable to Stored XSS. It allows an attacker to inject malicious JavaScript code on the WooCommerce -> Orders admin page. The attack is possible by modifying the "referral_site" cookie to have an XSS payload, and placing an order. |
| /usr/lib/lua/luci/websys.lua on TP-LINK IPC TL-IPC223(P)-6, TL-IPC323K-D, TL-IPC325(KP)-*, and TL-IPC40A-4 devices has a hardcoded zMiVw8Kw0oxKXL0 password. |
| TP-LINK IPC TL-IPC223(P)-6, TL-IPC323K-D, TL-IPC325(KP)-*, and TL-IPC40A-4 devices allow authenticated remote code execution via crafted JSON data because /usr/lib/lua/luci/torchlight/validator.lua does not block various punctuation characters. |
| The VPN component in Windscribe 1.81 uses the OpenVPN client for connections. Also, it creates a WindScribeService.exe system process that establishes a \\.\pipe\WindscribeService named pipe endpoint that allows the Windscribe VPN process to connect and execute an OpenVPN process or other processes (like taskkill, etc.). There is no validation of the program name before constructing the lpCommandLine argument for a CreateProcess call. An attacker can run any malicious process with SYSTEM privileges through this named pipe. |
| An issue was discovered on Vgate iCar 2 Wi-Fi OBD2 Dongle devices. The OBD port is used to receive measurement data and debug information from the car. This on-board diagnostics feature can also be used to send commands to the car (different for every vendor / car product line / car). No authentication is needed, which allows attacks from the local Wi-Fi network. |
| An issue was discovered on Vgate iCar 2 Wi-Fi OBD2 Dongle devices. The data packets that are sent between the iOS or Android application and the OBD dongle are not encrypted. The combination of this vulnerability with the lack of wireless network protection exposes all transferred car data to the public. |
| An issue was discovered on Vgate iCar 2 Wi-Fi OBD2 Dongle devices. The dongle opens an unprotected wireless LAN that cannot be configured with encryption or a password. This enables anyone within the range of the WLAN to connect to the network without authentication. |
| Monstra CMS 3.0.4 has a Session Management Issue in the Users tab. A password change at users/1/edit does not invalidate a session that is open in a different browser. |
| Monstra CMS 3.0.4 has a Session Management Issue in the Administrations Tab. A password change at admin/index.php?id=users&action=edit&user_id=1 does not invalidate a session that is open in a different browser. |
| Monstra CMS 3.0.4 has XSS in the registration Form (i.e., the login parameter to users/registration). |
| Monstra CMS 3.0.4 has Reflected XSS during Login (i.e., the login parameter to admin/index.php). |
| Cockpit 0.5.5 has XSS via a collection, form, or region. |
| iScripts eSwap v2.4 has SQL injection via the "search.php" 'Told' parameter in the User Panel. |
| Incorrect caching of responses to requests including an Authorization header in HAProxy 1.8.0 through 1.8.9 (if cache enabled) allows attackers to achieve information disclosure via an unauthenticated remote request, related to the proto_http.c check_request_for_cacheability function. |
| The __mkd_trim_line function in mkdio.c in libmarkdown.a in DISCOUNT 2.2.3a allows remote attackers to cause a denial of service (heap-based buffer over-read) via a crafted file, as demonstrated by mkd2html. |
| A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). Specially crafted network packets sent to port 102/tcp (ISO-TSAP) could allow a remote attacker to either cause a Denial-of-Service condition of the integrated software firewall or allow to execute code in the context of the software firewall. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 102/tcp. Successful exploitation requires no user privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known |
| A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker could use ioctl calls to do out of bounds reads, arbitrary writes, or execute code in kernel mode. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. |
| A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a Denial-of-Service condition of the VNC server. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known. |
| A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A buffer overflow in the service command application could allow a local attacker to execute code with elevated privileges. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. |