| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A stored cross-site scripting (XSS) vulnerability in Shopizer before 2.17.0 allows remote attackers to inject arbitrary web script or HTML via customer_name in various forms of store administration. It is saved in the database. The code is executed for any user of store administration when information is fetched from the backend, e.g., in admin/customers/list.html. |
| Boa 0.94.13 allows remote attackers to obtain sensitive information via a misconfiguration involving backup.html, preview.html, js/log.js, log.html, email.html, online-users.html, and config.js. NOTE: multiple third parties report that this is a site-specific issue because those files are not part of Boa. |
| An XSS issue was discovered in manage_custom_field_edit_page.php in MantisBT before 2.25.2. Unescaped output of the return parameter allows an attacker to inject code into a hidden input field. |
| In PEPPERL+FUCHS WirelessHART-Gateway <= 3.0.7 the filename parameter is vulnerable to unauthenticated path traversal attacks, enabling read access to arbitrary files on the server. |
| Multiple camera devices by UDP Technology, Geutebrück and other vendors are vulnerable to command injection, which may allow an attacker to remotely execute arbitrary code. |
| Multiple camera devices by UDP Technology, Geutebrück and other vendors are vulnerable to command injection, which may allow an attacker to remotely execute arbitrary code. |
| Multiple camera devices by UDP Technology, Geutebrück and other vendors are vulnerable to command injection, which may allow an attacker to remotely execute arbitrary code. |
| Multiple camera devices by UDP Technology, Geutebrück and other vendors are vulnerable to command injection, which may allow an attacker to remotely execute arbitrary code. |
| Multiple camera devices by UDP Technology, Geutebrück and other vendors are vulnerable to command injection, which may allow an attacker to remotely execute arbitrary code. |
| Multiple camera devices by UDP Technology, Geutebrück and other vendors are vulnerable to a stack-based buffer overflow condition in the action parameter, which may allow an attacker to remotely execute arbitrary code. |
| Multiple camera devices by UDP Technology, Geutebrück and other vendors are vulnerable to command injection, which may allow an attacker to remotely execute arbitrary code. |
| Multiple camera devices by UDP Technology, Geutebrück and other vendors are vulnerable to a stack-based buffer overflow condition in the profile parameter which may allow an attacker to remotely execute arbitrary code. |
| Multiple camera devices by UDP Technology, Geutebrück and other vendors are vulnerable to a stack-based buffer overflow condition in the name parameter, which may allow an attacker to remotely execute arbitrary code. |
| Multiple camera devices by UDP Technology, Geutebrück and other vendors are vulnerable to a stack-based buffer overflow condition in the counter parameter which may allow an attacker to remotely execute arbitrary code. |
| Multiple camera devices by UDP Technology, Geutebrück and other vendors are vulnerable to command injection, which may allow an attacker to remotely execute arbitrary code. |
| Multiple camera devices by UDP Technology, Geutebrück and other vendors allow unauthenticated remote access to sensitive files due to default user authentication settings. This can lead to manipulation of the device and denial of service. |
| Phoenix Contact Classic Automation Worx Software Suite in Version 1.87 and below is affected by a remote code execution vulnerability. Manipulated PC Worx or Config+ projects could lead to a remote code execution when unallocated memory is freed because of incompletely initialized data. The attacker needs to get access to an original bus configuration file (*.bcp) to be able to manipulate data inside. After manipulation the attacker needs to exchange the original file by the manipulated one on the application programming workstation. Availability, integrity, or confidentiality of an application programming workstation might be compromised by attacks using these vulnerabilities. Automated systems in operation which were programmed with one of the above-mentioned products are not affected. |
| Phoenix Contact Classic Line Controllers ILC1x0 and ILC1x1 in all versions/variants are affected by a Denial-of-Service vulnerability. The communication protocols and device access do not feature authentication measures. Remote attackers can use specially crafted IP packets to cause a denial of service on the PLC's network communication module. A successful attack stops all network communication. To restore the network connectivity the device needs to be restarted. The automation task is not affected. |
| In certain devices of the Phoenix Contact AXL F BK and IL BK product families an undocumented password protected FTP access to the root directory exists. |
| In Weidmueller Industrial WLAN devices in multiple versions an exploitable authentication bypass vulnerability exists in the hostname processing. A specially configured device hostname can cause the device to interpret selected remote traffic as local traffic, resulting in a bypass of web authentication. An attacker can send authenticated SNMP requests to trigger this vulnerability. |