| An improper access control vulnerability was identified in GitHub Enterprise Server that allowed authenticated users of the instance to gain write access to unauthorized repositories via specifically crafted pull requests and REST API requests. An attacker would need to be able to fork the targeted repository, a setting that is disabled by default for organization owned private repositories. Branch protections such as required pull request reviews or status checks would prevent unauthorized commits from being merged without further review or validation. This vulnerability affected all versions of GitHub Enterprise Server since 2.4.21 and was fixed in versions 2.20.24, 2.21.15, 2.22.7 and 3.0.1. This vulnerability was reported via the GitHub Bug Bounty program. |
| EIC e-document system does not perform completed identity verification for sorting and filtering personnel data. The vulnerability allows remote attacker to obtain users’ credential information without logging in the system, and further acquire the privileged permissions and execute arbitrary commends. |
| The users’ data querying function of EIC e-document system does not filter the special characters which resulted in remote attackers can inject SQL syntax and execute arbitrary commands without privilege. |
| Attackers can access the CGE account management function without privilege for permission elevation and execute arbitrary commands or files after obtaining user permissions. |
| The CGE page with download function contains a Directory Traversal vulnerability. Attackers can use this loophole to download system files arbitrarily. |
| The CGE property management system contains SQL Injection vulnerabilities. Remote attackers can inject SQL commands into the parameters in Cookie and obtain data in the database without privilege. |
| The specific function of HR Portal of Soar Cloud System accepts any type of object to be deserialized. Attackers can send malicious serialized objects to execute arbitrary commands. |
| The HR Portal of Soar Cloud System fails to filter specific parameters. Remote attackers can inject SQL syntax and obtain all data in the database without privilege. |
| The HR Portal of Soar Cloud System fails to manage access control. While obtaining user ID, remote attackers can access sensitive data via a specific data packet, such as user’s login information, further causing the login function not to work. |
| HGiga EIP product contains SQL Injection vulnerability. Attackers can inject SQL commands into specific URL parameter (online registration) to obtain database schema and data. |
| HGiga EIP product contains SQL Injection vulnerability. Attackers can inject SQL commands into specific URL parameter (document management page) to obtain database schema and data. |
| HGiga EIP product lacks ineffective access control in certain pages that allow attackers to access database or perform privileged functions. |
| Hyweb HyCMS-J1 backend editing function does not filter special characters. Users after log-in can inject JavaScript syntax to perform a stored XSS (Stored Cross-site scripting) attack. |
| HGiga MailSherlock contains a SQL Injection. Remote attackers can inject SQL syntax and execute SQL commands in a URL parameter of email pages without privilege. |
| Hyweb HyCMS-J1's API fail to filter POST request parameters. Remote attackers can inject SQL syntax and execute commands without privilege. |
| A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22826. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior versions |
| A CWE-20: Improper Input Validation vulnerability exists that could cause arbitrary code execution when the user visits a page containing the injected payload. This CVE is unique from CVE-2021-22827. Affected Product: EcoStruxure� Power Monitoring Expert 9.0 and prior versions |
| A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in denial of service, due to missing length check on user-supplied data from a constructed message received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior) |
| A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior) |
| A CWE-79 Improper Neutralization of Input During Web Page Generation (�Cross-site Scripting�) vulnerability exists that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2) |