Search Results (356018 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-45707 2 Czlonkowski, N8n-mcp 2 N8n-mcp, N8n-mcp 2026-06-01 8.1 High
n8n-MCP is an MCP server that provides AI assistants access to n8n node documentation, properties, and operations. Prior to 2.51.2, when ENABLE_MULTI_TENANT=true, the HTTP transport documents that the target n8n instance is selected per-request from x-n8n-url / x-n8n-key headers. Requests that omitted those headers — or supplied only one of them — silently fell back to the process-level N8N_API_URL / N8N_API_KEY credentials configured for the operator's own n8n instance. As a result, an authenticated MCP tenant could cause n8n management calls to execute against the operator's instance instead of its own. This affects HTTP-mode deployments of n8n-mcp that are run as a shared multi-tenant service. Single-tenant deployments (ENABLE_MULTI_TENANT unset or false) are not affected. This vulnerability is fixed in 2.51.2.
CVE-2026-43081 1 Linux 1 Linux Kernel 2026-06-01 5.5 Medium
In the Linux kernel, the following vulnerability has been resolved: net: ipa: fix GENERIC_CMD register field masks for IPA v5.0+ Fix the field masks to match the hardware layout documented in downstream GSI (GSI_V3_0_EE_n_GSI_EE_GENERIC_CMD_*). Notably this fixes a WARN I was seeing when I tried to send "stop" to the MPSS remoteproc while IPA was up.
CVE-2025-41265 2 Waterfall, Waterfall-security 3 Wf-500, Wf-500, Wf-500 Firmware 2026-06-01 7.2 High
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Administration WebUI in Waterfall WF-500 TX Host in version 7.9.1.0 R2502171040 that allows remote authenticated attackers to execute arbitrary operating system commands on the WF-500 TX Host.
CVE-2025-41266 2 Waterfall, Waterfall-security 3 Wf-500, Wf-500, Wf-500 Firmware 2026-06-01 7.2 High
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Administration WebUI in Waterfall WF-500 TX Host in version 7.9.1.0 R2502171040 that allows remote authenticated attackers to execute arbitrary operating system commands on the WF-500 TX Host.
CVE-2025-41267 2 Waterfall, Waterfall-security 3 Wf-500, Wf-500, Wf-500 Firmware 2026-06-01 7.2 High
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Administration WebUI in Waterfall WF-500 TX Host in version 7.9.1.0 R2502171040 that allows remote authenticated attackers to execute arbitrary operating system commands on the WF-500 TX Host.
CVE-2025-41268 2 Waterfall, Waterfall-security 3 Wf-500, Wf-500, Wf-500 Firmware 2026-06-01 9.1 Critical
Nozomi Networks Labs identified a CWE-23: Relative Path Traversal in the Administration WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to delete arbitrary files on the Host machines.
CVE-2025-41269 2 Waterfall, Waterfall-security 3 Wf-500, Wf-500, Wf-500 Firmware 2026-06-01 9.8 Critical
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device.
CVE-2025-41270 2 Waterfall, Waterfall-security 3 Wf-500, Wf-500, Wf-500 Firmware 2026-06-01 9.8 Critical
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device.
CVE-2025-41271 2 Waterfall, Waterfall-security 3 Wf-500, Wf-500, Wf-500 Firmware 2026-06-01 7.5 High
Nozomi Networks Labs identified a CWE-23: Relative Path Traversal in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to read arbitrary files from the device.
CVE-2025-41272 2 Waterfall, Waterfall-security 3 Wf-500, Wf-500, Wf-500 Firmware 2026-06-01 9.8 Critical
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device.
CVE-2025-41273 2 Waterfall, Waterfall-security 3 Wf-500, Wf-500, Wf-500 Firmware 2026-06-01 9.8 Critical
Nozomi Networks Labs identified a CWE-288: Authentication Bypass Using an Alternate Path or Channel in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to bypass authentication of the Console web application and perform actions as an authenticated user.
CVE-2025-41274 2 Waterfall, Waterfall-security 3 Wf-500, Wf-500, Wf-500 Firmware 2026-06-01 9.8 Critical
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device.
CVE-2025-41275 2 Waterfall, Waterfall-security 3 Wf-500, Wf-500, Wf-500 Firmware 2026-06-01 9.8 Critical
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device.
CVE-2025-41276 2 Waterfall, Waterfall-security 3 Wf-500, Wf-500, Wf-500 Firmware 2026-06-01 9.8 Critical
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device.
CVE-2025-41277 2 Waterfall, Waterfall-security 3 Wf-500, Wf-500, Wf-500 Firmware 2026-06-01 9.8 Critical
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Console WebUI in Waterfall WF-500 TX and RX Hosts in version 7.9.1.0 R2502171040 that allows remote unauthenticated attackers to execute arbitrary operating system commands on the device.
CVE-2025-41278 2 Waterfall, Waterfall-security 3 Wf-500, Wf-500, Wf-500 Firmware 2026-06-01 7.8 High
Nozomi Networks Labs identified a CWE-125: Out-of-bounds Read in Waterfall WF-500 RX Host in version 7.10.0.0 R2601141040 that allows attackers with access to the TX Host to execute code on the RX Host.
CVE-2025-41280 2 Waterfall, Waterfall-security 3 Wf-500, Wf-500, Wf-500 Firmware 2026-06-01 7.8 High
Nozomi Networks Labs identified a CWE-23: Relative Path Traversal (Zip Slip) in Waterfall WF-500 RX Host in version 7.9.1.0 R2502171040 that allows attackers with access to the TX Host to execute code on the RX Host when a MySQL connector is configured and file compression is enabled.
CVE-2025-41279 2 Waterfall, Waterfall-security 3 Wf-500, Wf-500, Wf-500 Firmware 2026-06-01 7.2 High
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in the Administration WebUI in Waterfall WF-500 RX Host in version 7.9.1.0 R2502171040 that allows remote authenticated attackers to execute arbitrary operating system commands on the WF-500 RX Host.
CVE-2025-41281 2 Waterfall, Waterfall-security 3 Wf-500, Wf-500, Wf-500 Firmware 2026-06-01 7.8 High
Nozomi Networks Labs identified a CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') in Waterfall WF-500 RX Host in version 7.9.1.0 R2502171040 that allows attackers with access to the TX Host to execute code on the RX Host when a MySQL connector is configured.
CVE-2026-45344 1 Kovah 1 Linkace 2026-06-01 8.1 High
LinkAce is a self-hosted archive to collect website links. Prior to 2.5.6, the setup database configuration flow on uninitialized LinkAce instances accepts attacker-controlled database credential fields and writes them back into .env without escaping. A remote attacker who can reach the setup endpoints and supply a database they control can inject mail configuration variables and achieve command execution when the application later sends mail. This vulnerability is fixed in 2.5.6.