| Texas Instruments TI-RTOS, when configured to use HeapMem heap(default),
malloc returns a valid pointer to a small buffer on extremely large
values, which can trigger an integer overflow vulnerability in
'HeapMem_allocUnprotected' and result in code execution. |
| Ypsomed mylife Cloud, mylife Mobile Application, Ypsomed mylife Cloud: All versions prior to 1.7.2, Ypsomed mylife App: All versions prior to 1.7.5,The application layer encryption of the communication protocol between the Ypsomed mylife App and mylife Cloud uses non-random IVs, which allows man-in-the-middle attackers to tamper with messages. |
| Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior lack proper validation of user-supplied data when parsing PRT files. This could lead to pointer dereferences of a value obtained from an untrusted source. An attacker could leverage this vulnerability to execute code in the context of the current process. |
| Ypsomed mylife Cloud, mylife Mobile Application:Ypsomed mylife Cloud,All versions prior to 1.7.2,Ypsomed mylife App,All versions prior to 1.7.5,he Ypsomed mylife Cloud reflects the user password during the login process after redirecting the user from a HTTPS endpoint to a HTTP endpoint. |
| Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior lack proper validation of user-supplied data when parsing STP files. This could result in a stack-based buffer overflow. An attacker could leverage this vulnerability to execute code in the context of the current process. |
| When opening a specially crafted 3DXML file, the application containing Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior could disclose arbitrary files to remote attackers. This is because of the passing of specially crafted content to the underlying XML parser without taking proper restrictions such as prohibiting an external DTD. |
| Ypsomed mylife Cloud, mylife Mobile Application:Ypsomed mylife Cloud,All versions prior to 1.7.2,Ypsomed mylife App,All versions prior to 1.7.5,The Ypsomed mylife Cloud discloses password hashes during the registration process. |
| Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior are vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code. |
| ZOLL Defibrillator Dashboard, v prior to 2.2, The web application allows a non-administrative user to upload a malicious file. This file could allow an attacker to remotely execute arbitrary commands. |
| Datakit Software libraries CatiaV5_3dRead, CatiaV6_3dRead, Step3dRead, Ug3dReadPsr, Jt3dReadPsr modules in KeyShot Versions v10.1 and prior lack proper validation of user-supplied data when parsing CATPart files. This could result in an out-of-bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. |
| ZOLL Defibrillator Dashboard, v prior to 2.2, The affected products contain credentials stored in plaintext. This could allow an attacker to gain access to sensitive information. |
| FATEK Automation WinProladder Versions 3.30 and prior is vulnerable to an integer underflow, which may cause an out-of-bounds write and allow an attacker to execute arbitrary code. |
| ZOLL Defibrillator Dashboard, v prior to 2.2,The application allows users to store their passwords in a recoverable format, which could allow an attacker to retrieve the credentials from the web browser. |
| ZOLL Defibrillator Dashboard, v prior to 2.2,The affected products contain insecure filesystem permissions that could allow a lower privilege user to escalate privileges to an administrative level user. |
| ZOLL Defibrillator Dashboard, v prior to 2.2, The affected products utilize an encryption key in the data exchange process, which is hardcoded. This could allow an attacker to gain access to sensitive information. |
| Delta Industrial Automation COMMGR Versions 1.12 and prior are vulnerable to a stack-based buffer overflow, which may allow an attacker to execute remote code. |
| ZOLL Defibrillator Dashboard, v prior to 2.2,The affected product’s web application could allow a low privilege user to inject parameters to contain malicious scripts to be executed by higher privilege users. |
| When JTEKT Corporation TOYOPUC PLC versions PC10G-CPU, 2PORT-EFR, Plus CPU, Plus EX, Plus EX2, Plus EFR, Plus EFR2, Plus 2P-EFR, PC10P-DP, PC10P-DP-IO, Plus BUS-EX, Nano 10GX, Nano 2ET,PC10PE, PC10PE-16/16P, PC10E, FL/ET-T-V2H, PC10B,PC10B-P, Nano CPU, PC10P, and PC10GE receive an invalid frame, the outside area of a receive buffer for FL-net are overwritten. As a result, the PLC CPU detects a system error, and the affected products stop. |
| A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected product’s web interface allows an attacker to route click or keystroke to another page provided by the attacker to gain unauthorized access to sensitive information. |
| A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected applications do not validate webpage input, which could allow an attacker to inject arbitrary HTML code into a webpage. This would allow an attacker to modify the page and display incorrect or undesirable data. |