CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. |
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. |
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input. |
A vulnerability, which was classified as critical, was found in Tenda AC7 1200M 15.03.06.44. Affected is the function TendaTelnet of the file /goform/telnet. The manipulation of the argument lan_ip leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. |
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. |
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. |
A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. Affected by this issue is the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument pptp_server_start_ip/pptp_server_end_ip leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. |
A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. Affected by this vulnerability is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument reboot_time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. |
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function fromSafeSetMacFilter of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. |
A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
A vulnerability, which was classified as critical, was found in Tenda AC7 up to 15.03.06.44. This affects the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. |
Tenda AC7 V1.0 V15.03.06.44 found a buffer overflow caused by the timeZone parameter in the form_fast_setting_wifi_set function, which can cause RCE. |
A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the formWifiBasicSet function. |
Tenda AC7 v.15.03.06.44 ate_iwpriv_set has pre-authentication command injection allowing remote attackers to execute arbitrary code. |
Tenda AC7 v.15.03.06.44 ate_ifconfig_set has pre-authentication command injection allowing remote attackers to execute arbitrary code. |
Tenda AC7V1.0 v15.03.06.44 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function. |
Tenda AC7V1.0 v15.03.06.44 firmware contains a command injection vulnerablility in formexeCommand function via the cmdinput parameter. |
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257937 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |