Filtered by vendor Eaton
Subscriptions
Total
44 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2023-43777 | 1 Eaton | 1 Easysoft | 2024-11-21 | 5.9 Medium |
Eaton easySoft software is used to program easy controllers and displays for configuring, programming and defining parameters for all the intelligent relays. This software has a password protection functionality to secure the project file from unauthorized access. This password was being stored insecurely and could be retrieved by skilled adversaries. | ||||
CVE-2023-43776 | 1 Eaton | 44 Easy-box-e4-ac1, Easy-box-e4-ac1 Firmware, Easy-box-e4-dc1 and 41 more | 2024-11-21 | 6.8 Medium |
Eaton easyE4 PLC offers a device password protection functionality to facilitate a secure connection and prevent unauthorized access. It was observed that the device password was stored with a weak encoding algorithm in the easyE4 program file when exported to SD card (*.PRG file ending). | ||||
CVE-2023-43775 | 1 Eaton | 8 Smp 16, Smp 16 Firmware, Smp 4\/dp and 5 more | 2024-11-21 | 4.7 Medium |
Denial-of-service vulnerability in the web server of the Eaton SMP Gateway allows attacker to potentially force an unexpected restart of the automation platform, impacting the availability of the product. In rare situations, the issue could cause the SMP device to restart in Safe Mode or Max Safe Mode. When in Max Safe Mode, the product is not vulnerable anymore. | ||||
CVE-2022-33859 | 1 Eaton | 1 Foreseer Electrical Power Monitoring System | 2024-11-21 | 8.1 High |
A security vulnerability was discovered in the Eaton Foreseer EPMS software. Foreseer EPMS connects an operation’s vast array of devices to assist in the reduction of energy consumption and avoid unplanned downtime caused by the failures of critical systems. A threat actor may upload arbitrary files using the file upload feature. This vulnerability is present in versions 4.x, 5.x, 6.x & 7.0 to 7.5. A new version (v7.6) containing the remediation has been made available by Eaton and a mitigation has been provided for the affected versions that are currently supported. Customers are advised to update the software to the latest version (v7.6). Foreseer EPMS versions 4.x, 5.x, 6.x are no longer supported by Eaton. Please refer to the End-of-Support notification https://www.eaton.com/in/en-us/catalog/services/foreseer/foreseer-legacy.html . | ||||
CVE-2021-23288 | 1 Eaton | 1 Intelligent Power Protector | 2024-11-21 | 5.6 Medium |
The vulnerability exists due to insufficient validation of input from certain resources by the IPP software. The attacker would need access to the local Subnet and an administrator interaction to compromise the system. This issue affects: Intelligent Power Protector versions prior to 1.69. | ||||
CVE-2021-23287 | 1 Eaton | 1 Intelligent Power Manager | 2024-11-21 | 5.6 Medium |
The vulnerability exists due to insufficient validation of input of certain resources within the IPM software. This issue affects: Intelligent Power Manager (IPM 1) versions prior to 1.70. | ||||
CVE-2021-23286 | 1 Eaton | 1 Intelligent Power Manager | 2024-11-21 | 5.7 Medium |
Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) version 1.5.0plus205 and all prior versions are vulnerable to CSV Formula Injection. This issue affects: Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) all version 1.5.0plus205 and prior versions. | ||||
CVE-2021-23285 | 1 Eaton | 1 Intelligent Power Manager | 2024-11-21 | 3.1 Low |
Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) version 1.5.0plus205 and all prior versions are vulnerable to reflected Cross-site Scripting vulnerability. This issue affects: Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) all version 1.5.0plus205 and prior versions. | ||||
CVE-2021-23284 | 1 Eaton | 1 Intelligent Power Manager Infrastructure | 2024-11-21 | 5.7 Medium |
Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) version 1.5.0plus205 and all prior versions are vulnerable to Stored Cross-site Scripting vulnerability. This issue affects: Eaton Intelligent Power Manager Infrastructure (IPM Infrastructure) all version 1.5.0plus205 and prior versions. | ||||
CVE-2021-23283 | 1 Eaton | 1 Intelligent Power Protector | 2024-11-21 | 5.2 Medium |
Eaton Intelligent Power Protector (IPP) prior to version 1.69 is vulnerable to stored Cross Site Scripting. The vulnerability exists due to insufficient validation of user input and improper encoding of the output for certain resources within the IPP software. | ||||
CVE-2021-23281 | 1 Eaton | 1 Intelligent Power Manager | 2024-11-21 | 10 Critical |
Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to unauthenticated remote code execution vulnerability. IPM software does not sanitize the date provided via coverterCheckList action in meta_driver_srv.js class. Attackers can send a specially crafted packet to make IPM connect to rouge SNMP server and execute attacker-controlled code. | ||||
CVE-2021-23280 | 1 Eaton | 3 Intelligent Power Manager, Intelligent Power Manager Virtual Appliance, Intelligent Power Protector | 2024-11-21 | 8 High |
Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to authenticated arbitrary file upload vulnerability. IPM’s maps_srv.js allows an attacker to upload a malicious NodeJS file using uploadBackgroud action. An attacker can upload a malicious code or execute any command using a specially crafted packet to exploit the vulnerability. | ||||
CVE-2021-23279 | 1 Eaton | 3 Intelligent Power Manager, Intelligent Power Manager Virtual Appliance, Intelligent Power Protector | 2024-11-21 | 8 High |
Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to unauthenticated arbitrary file delete vulnerability induced due to improper input validation in meta_driver_srv.js class with saveDriverData action using invalidated driverID. An attacker can send specially crafted packets to delete the files on the system where IPM software is installed. | ||||
CVE-2021-23278 | 1 Eaton | 3 Intelligent Power Manager, Intelligent Power Manager Virtual Appliance, Intelligent Power Protector | 2024-11-21 | 8.7 High |
Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to authenticated arbitrary file delete vulnerability induced due to improper input validation at server/maps_srv.js with action removeBackground and server/node_upgrade_srv.js with action removeFirmware. An attacker can send specially crafted packets to delete the files on the system where IPM software is installed. | ||||
CVE-2021-23277 | 1 Eaton | 3 Intelligent Power Manager, Intelligent Power Manager Virtual Appliance, Intelligent Power Protector | 2024-11-21 | 8.3 High |
Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to unauthenticated eval injection vulnerability. The software does not neutralize code syntax from users before using in the dynamic evaluation call in loadUserFile function under scripts/libs/utils.js. Successful exploitation can allow attackers to control the input to the function and execute attacker controlled commands. | ||||
CVE-2021-23276 | 1 Eaton | 3 Intelligent Power Manager, Intelligent Power Manager Virtual Appliance, Intelligent Power Protector | 2024-11-21 | 7.1 High |
Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to authenticated SQL injection. A malicious user can send a specially crafted packet to exploit the vulnerability. Successful exploitation of this vulnerability can allow attackers to add users in the data base. | ||||
CVE-2020-7915 | 1 Eaton | 2 5p 850, 5p 850 Firmware | 2024-11-21 | 4.8 Medium |
An issue was discovered on Eaton 5P 850 devices. The Ubicacion SAI field allows XSS attacks by an administrator. | ||||
CVE-2020-6656 | 1 Eaton | 1 Easysoft | 2024-11-21 | 5.8 Medium |
Eaton's easySoft software v7.xx prior to v7.22 are susceptible to file parsing type confusion remote code execution vulnerability. A malicious entity can execute a malicious code or make the application crash by tricking user upload a malformed .E70 file in the application. The vulnerability arises due to improper validation of user data supplied through E70 file which is causing Type Confusion. | ||||
CVE-2020-6655 | 1 Eaton | 1 Easysoft | 2024-11-21 | 5.8 Medium |
The Eaton's easySoft software v7.xx prior to v7.22 are susceptible to Out-of-bounds remote code execution vulnerability. A malicious entity can execute a malicious code or make the application crash by tricking user to upload the malformed .E70 file in the application. The vulnerability arises due to improper validation and parsing of the E70 file content by the application. | ||||
CVE-2020-6654 | 1 Eaton | 1 9000x Programming And Configuration Software | 2024-11-21 | 7.8 High |
A DLL Hijacking vulnerability in Eaton's 9000x Programming and Configuration Software v 2.0.38 and prior allows an attacker to execute arbitrary code by replacing the required DLLs with malicious DLLs when the software try to load vci11un6.DLL and cinpl.DLL. |