Filtered by vendor Selinc
Subscriptions
Total
47 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2013-2798 | 1 Selinc | 4 Sel-2241, Sel-3505, Sel-3530 and 1 more | 2024-09-17 | N/A |
Schweitzer Engineering Laboratories (SEL) SEL-2241, SEL-3505, and SEL-3530 RTAC master devices allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line. | ||||
CVE-2013-2792 | 1 Selinc | 4 Sel-2241, Sel-3505, Sel-3530 and 1 more | 2024-09-17 | N/A |
Schweitzer Engineering Laboratories (SEL) SEL-2241, SEL-3505, and SEL-3530 RTAC master devices allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet. | ||||
CVE-2013-0665 | 1 Selinc | 1 Acselerator Quickset | 2024-09-17 | N/A |
Schweitzer Engineering Laboratories (SEL) AcSELerator QuickSet before 5.12.0.1 uses weak permissions for its Program Files directory, which allows local users to replace executable files, and consequently gain privileges, via standard filesystem operations. | ||||
CVE-2018-10604 | 1 Selinc | 1 Sel Compass | 2024-09-16 | 8.8 High |
SEL Compass version 3.0.5.1 and prior allows all users full access to the SEL Compass directory, which may allow modification or overwriting of files within the Compass installation folder, resulting in escalation of privilege and/or malicious code execution. | ||||
CVE-2018-10608 | 1 Selinc | 1 Acselerator Architect | 2024-09-16 | N/A |
SEL AcSELerator Architect version 2.2.24.0 and prior can be exploited when the AcSELerator Architect FTP client connects to a malicious FTP server, which may cause denial of service via 100% CPU utilization. Restart of the application is required. | ||||
CVE-2018-10600 | 1 Selinc | 1 Acselerator Architect | 2024-09-16 | N/A |
SEL AcSELerator Architect version 2.2.24.0 and prior allows unsanitized input to be passed to the XML parser, which may allow disclosure and retrieval of arbitrary data, arbitrary code execution (in certain situations on specific platforms), and denial of service attacks. | ||||
CVE-2017-7928 | 1 Selinc | 4 Sel-3620, Sel-3620 Firmware, Sel-3622 and 1 more | 2024-08-05 | N/A |
An Improper Access Control issue was discovered in Schweitzer Engineering Laboratories (SEL) SEL-3620 and SEL-3622 Security Gateway Versions R202 and, R203, R203-V1, R203-V2 and, R204, R204-V1. The device does not properly enforce access control while configured for NAT port forwarding, which may allow for unauthorized communications to downstream devices. | ||||
CVE-2023-34388 | 1 Selinc | 2 Sel-451, Sel-451 Firmware | 2024-08-02 | 6.5 Medium |
An Improper Authentication vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote unauthenticated attacker to potentially perform session hijacking attack and bypass authentication. See product Instruction Manual Appendix A dated 20230830 for more details. | ||||
CVE-2023-34391 | 2 Microsoft, Selinc | 2 Windows, Sel-5033 Acselerator Real-time Automation Controller | 2024-08-02 | 7.4 High |
Insecure Inherited Permissions vulnerability in Schweitzer Engineering Laboratories SEL-5033 AcSELerator RTAC Software on Windows allows Leveraging/Manipulating Configuration File Search Paths. See Instruction Manual Appendix A [Cybersecurity] tag dated 20230522 for more details. This issue affects SEL-5033 AcSELerator RTAC Software: before 1.35.151.21000. | ||||
CVE-2023-34392 | 1 Selinc | 1 Sel-5037 Sel Grid Configurator | 2024-08-02 | 8.2 High |
A Missing Authentication for Critical Function vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to run arbitrary commands on managed devices by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20. | ||||
CVE-2023-34389 | 1 Selinc | 2 Sel-451, Sel-451 Firmware | 2024-08-02 | 4.5 Medium |
An allocation of resources without limits or throttling vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote authenticated attacker to make the system unavailable for an indefinite amount of time. See product Instruction Manual Appendix A dated 20230830 for more details. | ||||
CVE-2023-34390 | 1 Selinc | 2 Sel-451, Sel-451 Firmware | 2024-08-02 | 4.5 Medium |
An input validation vulnerability in the Schweitzer Engineering Laboratories SEL-451 could allow a remote authenticated attacker to create a denial of service against the system and locking out services. See product Instruction Manual Appendix A dated 20230830 for more details. | ||||
CVE-2023-31150 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2024-08-02 | 8 High |
A Storing Passwords in a Recoverable Format vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) database system could allow an authenticated attacker to retrieve passwords. See SEL Service Bulletin dated 2022-11-15 for more details. | ||||
CVE-2023-31168 | 1 Selinc | 1 Sel-5030 Acselerator Quickset | 2024-08-02 | 5.5 Medium |
An Inclusion of Functionality from Untrusted Control Sphere vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0. | ||||
CVE-2023-31167 | 2 Microsoft, Selinc | 2 Windows, Sel-5036 Acselerator Bay Screen Builder | 2024-08-02 | 5 Medium |
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in Schweitzer Engineering Laboratories SEL-5036 acSELerator Bay Screen Builder Software on Windows allows Relative Path Traversal. SEL acSELerator Bay Screen Builder software is distributed by SEL-5033 SEL acSELerator RTAC, SEL-5030 Quickset, and SEL Compass. CVE-2023-31167 and was patched in the acSELerator Bay Screen Builder release available on 20230602. Please contact SEL for additional details. This issue affects SEL-5036 acSELerator Bay Screen Builder Software: before 1.0.49152.778. | ||||
CVE-2023-31156 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2024-08-02 | 4.3 Medium |
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | ||||
CVE-2023-31160 | 1 Selinc | 20 Sel-2241 Rtac Module, Sel-2241 Rtac Module Firmware, Sel-3350 and 17 more | 2024-08-02 | 4.3 Medium |
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow a remote authenticated attacker to inject and execute arbitrary script code. See SEL Service Bulletin dated 2022-11-15 for more details. | ||||
CVE-2023-31171 | 1 Selinc | 1 Sel-5030 Acselerator Quickset | 2024-08-02 | 5.9 Medium |
An Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in the Schweitzer Engineering Laboratories SEL-5030 acSELerator QuickSet Software could allow an attacker to embed instructions that could be executed by an authorized device operator. See Instruction Manual Appendix A and Appendix E dated 20230615 for more details. This issue affects SEL-5030 acSELerator QuickSet Software: through 7.1.3.0. | ||||
CVE-2023-31161 | 1 Selinc | 10 Sel-3350, Sel-3350 Firmware, Sel-3532 and 7 more | 2024-08-02 | 5.9 Medium |
An Improper Input Validation vulnerability in the Schweitzer Engineering Laboratories Real-Time Automation Controller (SEL RTAC) Web Interface could allow an authenticated remote attacker to use internal resources, allowing a variety of potential effects. See SEL Service Bulletin dated 2022-11-15 for more details. | ||||
CVE-2023-31177 | 1 Selinc | 2 Sel-451, Sel-451 Firmware | 2024-08-02 | 4.3 Medium |
An Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') in the Schweitzer Engineering Laboratories SEL-451 could allow an attacker to craft a link that could execute arbitrary code on a victim's system. See product Instruction Manual Appendix A dated 20230830 for more details. |