Total
2023 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2024-0535 | 1 Tendacn | 2 Pa6, Pa6 Firmware | 2024-08-01 | 8.8 High |
A vulnerability classified as critical was found in Tenda PA6 1.0.1.21. Affected by this vulnerability is the function cgiPortMapAdd of the file /portmap of the component httpd. The manipulation of the argument groupName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-250705 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-0540 | 1 Tenda | 2 W9, W9 Firmware | 2024-08-01 | 6.3 Medium |
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. Affected is the function formOfflineSet of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-250710 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-0539 | 1 Tenda | 2 W9, W9 Firmware | 2024-08-01 | 8.8 High |
A vulnerability was found in Tenda W9 1.0.0.7(4456) and classified as critical. This issue affects the function formQosManage_user of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-250709 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-0534 | 1 Tenda | 2 A15, A15 Firmware | 2024-08-01 | 7.2 High |
A vulnerability classified as critical has been found in Tenda A15 15.13.07.13. Affected is an unknown function of the file /goform/SetOnlineDevName of the component Web-based Management Interface. The manipulation of the argument mac leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-250704. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-0577 | 1 Totolink | 2 Lr1200gb, Lr1200gb Firmware | 2024-08-01 | 8.8 High |
A vulnerability was found in Totolink LR1200GB 9.1.0u.6619_B20230130. It has been rated as critical. This issue affects the function setLanguageCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument lang leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-250793 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-0542 | 1 Tenda | 2 W9, W9 Firmware | 2024-08-01 | 8.8 High |
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been rated as critical. Affected by this issue is the function formWifiMacFilterGet of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-250712. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-0571 | 1 Totolink | 2 Lr1200gb, Lr1200gb Firmware | 2024-08-01 | 8.8 High |
A vulnerability, which was classified as critical, has been found in Totolink LR1200GB 9.1.0u.6619_B20230130. This issue affects the function setSmsCfg of the file /cgi-bin/cstecgi.cgi. The manipulation of the argument text leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-250787. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-0538 | 1 Tenda | 2 W9, W9 Firmware | 2024-08-01 | 8.8 High |
A vulnerability has been found in Tenda W9 1.0.0.7(4456) and classified as critical. This vulnerability affects the function formQosManage_auto of the component httpd. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-250708. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-0533 | 1 Tenda | 2 A15, A15 Firmware | 2024-08-01 | 7.2 High |
A vulnerability was found in Tenda A15 15.13.07.13. It has been rated as critical. This issue affects some unknown processing of the file /goform/SetOnlineDevName of the component Web-based Management Interface. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-250703. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-0532 | 1 Tenda | 2 A15, A15 Firmware | 2024-08-01 | 7.2 High |
A vulnerability was found in Tenda A15 15.13.07.13. It has been declared as critical. This vulnerability affects unknown code of the file /goform/WifiExtraSet of the component Web-based Management Interface. The manipulation of the argument wpapsk_crypto2_4g leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-250702 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-0531 | 1 Tenda | 2 A15, A15 Firmware | 2024-08-01 | 7.2 High |
A vulnerability was found in Tenda A15 15.13.07.13. It has been classified as critical. This affects an unknown part of the file /goform/setBlackRule of the component Web-based Management Interface. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-250701 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-0444 | 2024-08-01 | N/A | ||
GStreamer AV1 Video Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of GStreamer. Interaction with this library is required to exploit this vulnerability but attack vectors may vary depending on the implementation. The specific flaw exists within the parsing of tile list data within AV1-encoded video files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-22873. | ||||
CVE-2024-0321 | 1 Gpac | 1 Gpac | 2024-08-01 | 9.8 Critical |
Stack-based Buffer Overflow in GitHub repository gpac/gpac prior to 2.3-DEV. | ||||
CVE-2023-52758 | 2024-05-24 | 4.4 Medium | ||
This CVE ID has been rejected or withdrawn by its CVE Numbering Authority. | ||||
CVE-2021-47326 | 2024-05-23 | 5.3 Medium | ||
This CVE ID has been rejected or withdrawn by its CVE Numbering Authority. | ||||
CVE-2023-30079 | 1 Redhat | 2 Enterprise Linux, Rhel Eus | 2023-11-07 | 8.8 High |
DO NOT USE THIS CVE RECORD. ConsultIDs: CVE-2023-22652. Reason: This record is a duplicate of CVE-2023-22652. Notes: All CVE users should reference CVE-2023-22652 instead of this record. All references and descriptions in this record have been removed to prevent accidental usage. | ||||
CVE-2023-30078 | 2023-11-07 | 8.8 High | ||
DO NOT USE THIS CVE RECORD. ConsultIDs: CVE-2023-32181. Reason: This record is a duplicate of CVE-2023-32181. Notes: All CVE users should reference CVE-2023-32181 instead of this record. All references and descriptions in this record have been removed to prevent accidental usage. | ||||
CVE-2018-9060 | 2023-11-07 | N/A | ||
DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: none. Reason: This candidate was withdrawn by its CNA. Further investigation showed that it was not a security issue. Notes: none | ||||
CVE-2018-14378 | 2023-11-07 | N/A | ||
DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: none. Reason: This candidate was withdrawn by its CNA. Further investigation showed that it was not a security issue. Notes: none | ||||
CVE-2018-14375 | 2023-11-07 | N/A | ||
DO NOT USE THIS CANDIDATE NUMBER. ConsultIDs: none. Reason: This candidate was withdrawn by its CNA. Further investigation showed that it was not a security issue. Notes: none |