| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The Rockwell Automation Thinmanager Thinserver is impacted by an improper input validation vulnerability. Due to an improper input validation, a path traversal vulnerability exists, via the filename field, when the ThinManager processes a certain function. If exploited, an unauthenticated remote attacker can upload arbitrary files to any directory on the disk drive where ThinServer.exe is installed. A malicious user could exploit this vulnerability by sending a crafted synchronization protocol message and potentially gain remote code execution abilities.
|
| The Rockwell Automation Enhanced HIM software contains
an API that the application uses that is not protected sufficiently and uses incorrect Cross-Origin Resource Sharing (CORS) settings and, as a result, is vulnerable to a Cross Site Request Forgery (CSRF) attack. To exploit this vulnerability, a malicious user would have to convince a user to click on an untrusted link through a social engineering attack or successfully perform a Cross Site Scripting Attack (XSS). Exploitation of a CSRF could potentially lead to sensitive information disclosure and full remote access to the affected products.
|
| A vulnerability, which was classified as critical, was found in USR USR-G806 1.0.41. Affected is an unknown function of the component Web Management Page. The manipulation of the argument username/password with the input root leads to use of hard-coded password. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. It is recommended to change the configuration settings. VDB-228774 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
|
A buffer overflow vulnerability exists in the Rockwell Automation select 1756-EN* communication devices. If exploited, a threat actor could potentially leverage this vulnerability to perform a remote code execution. To exploit this vulnerability, a threat actor would have to send a maliciously crafted CIP request to device.
|
| A vulnerability, which was classified as critical, was found in MAXTECH MAX-G866ac 0.4.1_TBRO_20160314. This affects an unknown part of the component Remote Management. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-227001 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
|
Rockwell Automation FactoryTalk View Machine Edition on the PanelView Plus, improperly verifies user’s input, which allows unauthenticated attacker to achieve remote code executed via crafted malicious packets. The device has the functionality, through a CIP class, to execute exported functions from libraries. There is a routine that restricts it to execute specific functions from two dynamic link library files. By using a CIP class, an attacker can upload a self-made library to the device which allows the attacker to bypass the security check and execute any code written in the function.
|
| An issue discovered in Pfsense CE version 2.6.0 allows attackers to compromise user accounts via weak password requirements. |
| D-Link DIR-868L Hardware version A1, firmware version 1.12 is vulnerable to Buffer Overflow. The vulnerability is in scandir.sgi binary. |
| A use-after-free issue was discovered in Py_FindObjects() function in SciPy versions prior to 1.8.0. NOTE: the vendor and discoverer indicate that this is not a security issue. |
| PyroCMS 3.9 contains a remote code execution (RCE) vulnerability that can be exploited through a server-side template injection (SSTI) flaw. This vulnerability allows a malicious attacker to send customized commands to the server and execute arbitrary code on the affected system. |
| An issue was discovered in Heimdal Thor agent versions 3.4.2 and before 3.7.0 on Windows, allows attackers to bypass USB access restrictions, execute arbitrary code, and obtain sensitive information via Next-Gen Antivirus component. NOTE: Heimdal argues that the limitation described here is a Microsoft Windows issue, not a Heimdal specific vulnerability. The USB control solution by Heimdal is meant to manage Microsoft Windows native USB restrictions. They maintain that their solution functions as a management layer over Windows settings and is not to blame for limitations in Windows' detection capabilities. |
| An issue was discovered in Heimdal Thor agent versions 3.4.2 and before on Windows and 2.6.9 and before on macOS, allows attackers to bypass network filtering, execute arbitrary code, and obtain sensitive information via DarkLayer Guard threat prevention module. NOTE: Heimdal disputes the validity of this issue arguing that their DNS Security for Endpoint filters DNS traffic on the endpoint by intercepting system-generated DNS requests. The product was not designed to intercept DNS requests from third-party solutions. |
| Templates do not properly consider backticks (`) as Javascript string delimiters, and do not escape them as expected. Backticks are used, since ES6, for JS template literals. If a template contains a Go template action within a Javascript template literal, the contents of the action can be used to terminate the literal, injecting arbitrary Javascript code into the Go template. As ES6 template literals are rather complex, and themselves can do string interpolation, the decision was made to simply disallow Go template actions from being used inside of them (e.g., "var a = {{.}}"), since there is no obviously safe way to allow this behavior. This takes the same approach as github.com/google/safehtml. With fix, Template. Parse returns an Error when it encounters templates like this, with an ErrorCode of value 12. This ErrorCode is currently unexported but will be exported in the release of Go 1.21. Users who rely on the previous behavior can re-enable it using the GODEBUG flag jstmpllitinterp=1, with the caveat that backticks will now be escaped. This should be used with caution. |
| An issue in Zimbra Collaboration ZCS v.8.8.15 and v.9.0 allows an attacker to execute arbitrary code via the sfdc_preauth.jsp component. |
| An issue in Zimbra Collaboration (ZCS) v.8.8.15 and v.9.0 allows a remote attacker to escalate privileges and obtain sensitive information via the password and 2FA parameters. |
| A maliciously crafted PRT file when parsed through Autodesk AutoCAD 2024 and 2023 can be used to cause an Out-Of-Bounds Write. A malicious actor can leverage this vulnerability to cause a crash, read sensitive data, or execute arbitrary code in the context of the current process.
|
| A maliciously crafted CATPART file when parsed through Autodesk AutoCAD 2024 and 2023 can be used to cause an Out-Of-Bounds Write. A malicious actor can leverage this vulnerability to cause a crash, read sensitive data, or execute arbitrary code in the context of the current process.
|
| A maliciously crafted MODEL file when parsed through Autodesk AutoCAD 2024 and 2023 can be used to cause a Heap-Based Buffer Overflow. A malicious actor can leverage this vulnerability to cause a crash, read sensitive data, or execute arbitrary code in the context of the current process.
|
| AMI MegaRAC SPx12 and SPx13 devices have Insufficient Verification of Data Authenticity. |
| An Improper Verification of Cryptographic Signature in the SAML authentication of the Zscaler Admin UI allows a Privilege Escalation.This issue affects Admin UI: from 6.2 before 6.2r.
|