Search Results (2474 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2019-14833 3 Fedoraproject, Opensuse, Samba 3 Fedora, Leap, Samba 2024-11-21 5.4 Medium
A flaw was found in Samba, all versions starting samba 4.5.0 before samba 4.9.15, samba 4.10.10, samba 4.11.2, in the way it handles a user password change or a new password for a samba user. The Samba Active Directory Domain Controller can be configured to use a custom script to check for password complexity. This configuration can fail to verify password complexity when non-ASCII characters are used in the password, which could lead to weak passwords being set for samba users, making it vulnerable to dictionary attacks.
CVE-2019-14511 1 Sphinxsearch 1 Sphinx 2024-11-21 N/A
Sphinx Technologies Sphinx 3.1.1 by default has no authentication and listens on 0.0.0.0, making it exposed to the internet (unless filtered by a firewall or reconfigured to listen to 127.0.0.1 only).
CVE-2019-14351 1 Espocrm 1 Espocrm 2024-11-21 N/A
EspoCRM 5.6.4 is vulnerable to user password hash enumeration. A malicious authenticated attacker can brute-force a user password hash by 1 symbol at a time using specially crafted api/v1/User?filterList filters.
CVE-2019-14299 1 Ricoh 8 Sp C250dn, Sp C250dn Firmware, Sp C250sf and 5 more 2024-11-21 9.8 Critical
Ricoh SP C250DN 1.05 devices have an Authentication Method Vulnerable to Brute Force Attacks. Some Ricoh printers did not implement account lockout. Therefore, it was possible to obtain the local account credentials by brute force.
CVE-2019-14253 1 Publisure 1 Publisure 2024-11-21 6.5 Medium
An issue was discovered in servletcontroller in the secure portal in Publisure 2.1.2. One can bypass authentication and perform a query on PHP forms within the /AdminDir folder that should be restricted.
CVE-2019-13983 1 Rangerstudio 1 Directus 7 Api 2024-11-21 N/A
Directus 7 API before 2.2.2 has insufficient anti-automation, as demonstrated by lack of a CAPTCHA in core/Directus/Services/AuthService.php and endpoints/Auth.php.
CVE-2019-13933 1 Siemens 14 Scalance X-200rna, Scalance X-200rna Firmware, Scalance X-300 and 11 more 2024-11-21 8.6 High
A vulnerability has been identified in SCALANCE X204RNA (HSR), SCALANCE X204RNA (PRP), SCALANCE X204RNA EEC (HSR), SCALANCE X204RNA EEC (PRP), SCALANCE X204RNA EEC (PRP/HSR), SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices contain a vulnerability that allows an unauthenticated attacker to violate access-control rules. The vulnerability can be triggered by sending GET request to specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. An attacker could use the vulnerability to obtain sensitive information or change the device configuration. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13918 1 Siemens 1 Sinema Remote Connect Server 2024-11-21 9.8 Critical
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). The web interface has no means to prevent password guessing attacks. The vulnerability could be exploited by an attacker with network access to the vulnerable software, requiring no privileges and no user interaction. The vulnerability could allow full access to the web interface. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2019-13549 2 Carel, Rittal 2 Pcoweb Firmware, Chiller Sk 3232 2024-11-21 7.5 High
Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems does not provide a sufficient level of protection against unauthorized configuration changes. Primary operations, namely turning the cooling unit on and off and setting the temperature set point, can be modified without authentication.
CVE-2019-13547 1 Advantech 1 Wise-paas\/rmm 2024-11-21 9.8 Critical
Advantech WISE-PaaS/RMM, Versions 3.3.29 and prior. There is an unsecured function that allows anyone who can access the IP address to use the function without authentication.
CVE-2019-13525 1 Honeywell 2 Ip-ak2, Ip-ak2 Firmware 2024-11-21 5.3 Medium
In IP-AK2 Access Control Panel Version 1.04.07 and prior, the integrated web server of the affected devices could allow remote attackers to obtain web configuration data, which can be accessed without authentication over the network.
CVE-2019-13523 1 Honeywell 118 H2w2pc1m, H2w2pc1m Firmware, H2w2per3 and 115 more 2024-11-21 5.3 Medium
In Honeywell Performance IP Cameras and Performance NVRs, the integrated web server of the affected devices could allow remote attackers to obtain web configuration data in JSON format for IP cameras and NVRs (Network Video Recorders), which can be accessed without authentication over the network. Affected performance IP Cameras: HBD3PR2,H4D3PRV3,HED3PR3,H4D3PRV2,HBD3PR1,H4W8PR2,HBW8PR2,H2W2PC1M,H2W4PER3,H2W2PER3,HEW2PER3,HEW4PER3B,HBW2PER1,HEW4PER2,HEW4PER2B,HEW2PER2,H4W2PER2,HBW2PER2,H4W2PER3, and HPW2P1. Affected Performance Series NVRs: HEN08104,HEN08144,HEN081124,HEN16104,HEN16144,HEN16184,HEN16204,HEN162244,HEN16284,HEN16304,HEN16384,HEN32104,HEN321124,HEN32204,HEN32284,HEN322164,HEN32304, HEN32384,HEN323164,HEN64204,HEN64304,HEN643164,HEN643324,HEN643484,HEN04103,HEN04113,HEN04123,HEN08103,HEN08113,HEN08123,HEN08143,HEN16103,HEN16123,HEN16143,HEN16163,HEN04103L,HEN08103L,HEN16103L,HEN32103L.
CVE-2019-13406 1 Androvideo 2 Vd 1, Vd 1 Firmware 2024-11-21 N/A
A broken access control vulnerability found in Advan VD-1 firmware versions up to 230. An attacker can send a POST request to cgibin/ApkUpload.cgi to install arbitrary APK without any authentication.
CVE-2019-13405 1 Androvideo 2 Vd 1, Vd 1 Firmware 2024-11-21 N/A
A broken access control vulnerability found in Advan VD-1 firmware version 230 leads to insecure ADB service. An attacker can send a POST request to cgibin/AdbSetting.cgi to enable ADB without any authentication then take the compromised device as a relay or to install mining software.
CVE-2019-13344 1 Crudlab 1 Wp Like Button 2024-11-21 N/A
An authentication bypass vulnerability in the CRUDLab WP Like Button plugin through 1.6.0 for WordPress allows unauthenticated attackers to change settings. The contains() function in wp_like_button.php did not check if the current request is made by an authorized user, thus allowing any unauthenticated user to successfully update settings, as demonstrated by the wp-admin/admin.php?page=facebook-like-button each_page_url or code_snippet parameter.
CVE-2019-13338 1 Weseek 1 Growi 2024-11-21 N/A
In WESEEK GROWI before 3.5.0, a remote attacker can obtain the password hash of the creator of a page by leveraging wiki access to make API calls for page metadata. In other words, the password hash can be retrieved even though it is not a publicly available field.
CVE-2019-13205 1 Kyocera 2 Ecosys M5526cdw, Ecosys M5526cdw Firmware 2024-11-21 7.5 High
All configuration parameters of certain Kyocera printers (such as the ECOSYS M5526cdw 2R7_2000.001.701) were accessible by unauthenticated users. This information was only presented in the menus when authenticated, and the pages that loaded this information were also protected. However, all files that contained the configuration parameters were accessible. These files contained sensitive information, such as users, community strings, and other passwords configured in the printer.
CVE-2019-13194 1 Brother 600 Ads-2400n, Ads-2400n Firmware, Ads-2800w and 597 more 2024-11-21 7.5 High
Some Brother printers (such as the HL-L8360CDW v1.20) were affected by different information disclosure vulnerabilities that provided sensitive information to an unauthenticated user who visits a specific URL.
CVE-2019-13166 1 Xerox 2 Phaser 3320, Phaser 3320 Firmware 2024-11-21 7.5 High
Some Xerox printers (such as the Phaser 3320 V53.006.16.000) did not implement account lockout. Local account credentials may be extracted from the device via brute force guessing attacks.
CVE-2019-13131 1 Supermicro 1 Superdoctor 5 2024-11-21 N/A
Super Micro SuperDoctor 5, when restrictions are not implemented in agent.cfg, allows remote attackers to execute arbitrary commands via NRPE.