Filtered by vendor Schneider-electric Subscriptions
Total 753 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2018-7855 1 Schneider-electric 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more 2024-08-05 7.5 High
A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service when sending invalid breakpoint parameters to the controller over Modbus
CVE-2018-7841 1 Schneider-electric 1 U.motion Builder 2024-08-05 N/A
A SQL Injection (CWE-89) vulnerability exists in U.motion Builder software version 1.3.4 which could cause unwanted code execution when an improper set of characters is entered.
CVE-2018-7853 1 Schneider-electric 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more 2024-08-05 7.5 High
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading invalid physical memory blocks in the controller over Modbus
CVE-2018-7851 1 Schneider-electric 41 140cra312xxx, 140cra312xxx Firmware, Bmeh582040 and 38 more 2024-08-05 6.5 Medium
CWE-119: Buffer errors vulnerability exists in Modicon M580 with firmware prior to V2.50, Modicon M340 with firmware prior to V3.01, BMxCRA312xx with firmware prior to V2.40, All firmware versions of Modicon Premium and 140CRA312xxx when sending a specially crafted Modbus packet, which could cause a denial of service to the device that would force a restart to restore availability.
CVE-2018-7854 1 Schneider-electric 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more 2024-08-05 7.5 High
A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a denial of Service when sending invalid debug parameters to the controller over Modbus.
CVE-2018-7857 1 Schneider-electric 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more 2024-08-05 7.5 High
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible Denial of Service when writing out of bounds variables to the controller over Modbus.
CVE-2018-7846 1 Schneider-electric 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more 2024-08-05 9.8 Critical
A CWE-501: Trust Boundary Violation vulnerability on connection to the Controller exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum and Modicon Premium which could cause unauthorized access by conducting a brute force attack on Modbus protocol to the controller.
CVE-2018-7803 1 Schneider-electric 1 Triconex Tristation Emulator 2024-08-05 N/A
A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TriStation Emulator V1.2.0, which could cause the emulator to crash when sending a specially crafted packet. The emulator is used infrequently for application logic testing. It is susceptible to an attack only while running in off-line mode. This vulnerability does not exist in Triconex hardware products and therefore has no effect on the operating safety functions in a plant.
CVE-2018-7806 1 Schneider-electric 1 Struxureware Data Center Operation 2024-08-05 N/A
Data Center Operation allows for the upload of a zip file from its user interface to the server. A carefully crafted, malicious file could be mistakenly uploaded by an authenticated user via this feature which could contain path traversal file names. As such, it could allow for the arbitrary upload of files contained with the zip onto the server file system outside of the intended directory. This is leveraging the more commonly known ZipSlip vulnerability within Java code.
CVE-2018-7839 1 Schneider-electric 1 Iiot Monitor 2024-08-05 N/A
A Cryptographic Issue (CWE-310) vulnerability exists in IIoT Monitor 3.1.38 which could allow information disclosure.
CVE-2018-7835 1 Schneider-electric 1 Iiot Monior 2024-08-05 N/A
An Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in IIoT Monitor 3.1.38 which could allow access to files available to SYSTEM user.
CVE-2018-7856 1 Schneider-electric 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more 2024-08-05 7.5 High
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of Service when writing invalid memory blocks to the controller over Modbus.
CVE-2018-7843 1 Schneider-electric 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more 2024-08-05 7.5 High
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading memory blocks with an invalid data size or with an invalid data offset in the controller over Modbus.
CVE-2018-7834 1 Schneider-electric 2 Tsxetg100, Tsxetg100 Firmware 2024-08-05 N/A
A CWE-79 Cross-Site Scripting vulnerability exists in all versions of the TSXETG100 allowing an attacker to send a specially crafted URL with an embedded script to a user that would then be executed within the context of that user.
CVE-2018-7811 1 Schneider-electric 8 Modicom Bmxnor0200h, Modicom Bmxnor0200h Firmware, Modicom M340 and 5 more 2024-08-05 N/A
An Unverified Password Change vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 which could allow an unauthenticated remote user to access the change password function of the web server
CVE-2018-7836 1 Schneider-electric 1 Iiot Monitor 2024-08-05 N/A
An unrestricted Upload of File with Dangerous Type vulnerability exists on numerous methods of the IIoT Monitor 3.1.38 software that could allow upload and execution of malicious files.
CVE-2018-7848 1 Schneider-electric 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more 2024-08-05 7.5 High
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading files from the controller over Modbus
CVE-2018-7796 1 Schneider-electric 1 Powersuite 2 2024-08-05 N/A
A Buffer Error vulnerability exists in PowerSuite 2, all released versions (VW3A8104 & Patches), which could cause an overflow in the memcpy function, leading to corruption of data and program instability.
CVE-2018-7833 1 Schneider-electric 8 Modicom Bmxnor0200h, Modicom Bmxnor0200h Firmware, Modicom M340 and 5 more 2024-08-05 N/A
An Improper Check for Unusual or Exceptional Conditions vulnerability exists in the embedded web servers in all Modicon M340, Premium, Quantum PLCs and BMXNOR0200 where an unauthenticated user can send a specially crafted XML data via a POST request to cause the web server to become unavailable
CVE-2018-7844 1 Schneider-electric 8 Modicon M340, Modicon M340 Firmware, Modicon M580 and 5 more 2024-08-05 7.5 High
A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading memory blocks from the controller over Modbus.