A vulnerability was found in Weaver E-cology allows attackers use race conditions to bypass security mechanisms to upload malicious files and control server privileges
Search vulnerabilities
An improper input validation vulnerability in the “Quagga” package of the Zyxel ATP series firmware versions 4.32 through 5.37, USG FLEX series firmware versions 4.50 through 5.37, USG FLEX 50(W) series firmware versions 4.16 through 5.37, USG20(W)-VPN series firmware versions 4.16 through 5.37, and VPN series firmware versions 4.30 through 5.37, could allow an authenticated local attacker to access configuration files on an affected device.
Chamilo LMS File Upload Functionality Remote Code Execution
Unrestricted file upload in `/main/inc/ajax/exercise.ajax.php` in Chamilo LMS <= v1.11.24 allows authenticated attackers with learner role to obtain remote code execution via uploading of PHP files.
A cross-site request forgery (CSRF) vulnerability in Jenkins NeuVector Vulnerability Scanner Plugin 1.22 and earlier allows attackers to connect to an attacker-specified hostname and port using attacker-specified username and password.
October CMS stored XSS by authenticated backend user with improper configuration
October is a Content Management System (CMS) and web platform to assist with development workflow. A user with access to the media manager that stores SVG files could create a stored XSS attack against themselves and any other user with access to the media manager when SVG files are supported. This issue has been patched in version 3.5.2.
Symbolicator Server Side Request Forgery vulnerability
Symbolicator is a symbolication service for native stacktraces and minidumps with symbol server support. An attacker could make Symbolicator send arbitrary GET HTTP requests to internal IP addresses by using a specially crafted HTTP endpoint. The response could be reflected to the attacker if they have an account on Sentry instance. The issue has been fixed in the release 23.11.2.
Pimcore missing token/header to prevent CSRF
Customer-data-framework allows management of customer data within Pimcore. There are no tokens or headers to prevent CSRF attacks from occurring, therefore an attacker could abuse this vulnerability to create new customers. This issue has been patched in version 4.0.5.
Code Injection vulnerability in RhinOS from SaltOS
A vulnerability in RhinOS 3.0-1190 could allow PHP code injection through the "search" parameter in /portal/search.htm. This vulnerability could allow a remote attacker to perform a reverse shell on the remote system, compromising the entire infrastructure.
RhinOS 3.0 build 1190 allows CSRF.
Improper Authentication vulnerability in Samsung Pass prior to version 4.3.00.17 allows physical attackers to bypass authentication due to invalid exception handler.
802.11 heap buffer overflow
The 802.11 beacon handling routine failed to validate the length of an IEEE 802.11s Mesh ID before copying it to a heap-allocated buffer. While a FreeBSD Wi-Fi client is in scanning mode (i.e., not associated with a SSID) a malicious beacon frame may overwrite kernel memory, leading to remote code execution.
NETIS SYSTEMS MW5360 V1.0.1.3031 was discovered to contain a command injection vulnerability via the password parameter on the login page.
Orthanc versions before 1.12.2 are affected by a reflected cross-site scripting (XSS) vulnerability. The vulnerability was present in the server's error reporting.
Complete Supplier Management System v1.0 is vulnerable to SQL Injection via /Supply_Management_System/admin/edit_category.php?id=.
TOTOLINK X2000R_V2 V2.0.0-B20230727.10434 has a command injection vulnerability in the sub_449040 (handle function of formUploadFile) of /bin/boa.
Philips Clinical Collaboration Platform Configuration
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource.
Philips SureSigns VS4 Improper Access Control
Philips SureSigns VS4, A.07.107 and prior does not restrict or incorrectly restricts access to a resource from an unauthorized actor.
Philips SureSigns VS4 Improper Authentication
When an actor claims to have a given identity, Philips SureSigns VS4, A.07.107 and prior does not prove or insufficiently proves the claim is correct.
Philips SureSigns VS4 Improper Input Validation
Philips SureSigns VS4, A.07.107 and prior receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.
Philips Clinical Collaboration Platform Algorithm Downgrade
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not properly control the allocation and maintenance of a limited resource, thereby enabling an attacker to influence the amount of resources consumed, eventually leading to the exhaustion of available resources.