CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
Lack of authentication in file-viewing components in DDRT Dashcom Live 2019-05-09 allows anyone to remotely access all claim details by visiting easily guessable dashboard/uploads/claim_files/claim_id_ URLs. |
Lack of authentication in case-exporting components in DDRT Dashcom Live through 2019-05-08 allows anyone to remotely access all claim details by visiting easily guessable exportpdf/all_claim_detail.php?claim_id= URLs. |
Fujifilm FCR Capsula X/ Carbon X/ FCR XC-2, model versions CR-IR 357 FCR Carbon X, CR-IR 357 FCR XC-2, FCR-IR 357 FCR Capsula X provide insecure telnet services that lack authentication requirements. An attacker who successfully exploits this vulnerability may be able to access the underlying operating system. |
An issue was discovered in Joomla! before 3.9.5. The "refresh list of helpsites" endpoint of com_users lacks access checks, allowing calls from unauthenticated users. |
A vulnerability has been identified in SINEMA Server (All versions < V14 SP3). Missing authentication for functionality that requires administrative user identity could allow an attacker to obtain encoded system configuration backup files. This is only possible through network access to the affected system, and successful exploitation requires no system privileges. |
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 and newer (All versions), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 and newer (All versions). An attacker with network access to affected installations, which are configured without "Encrypted Communication", can execute arbitrary code. The security vulnerability could be exploited by an unauthenticated attacker with network access to the affected installation. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. |
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Attackers with access to port 10005/tcp could perform device reconfigurations and obtain project files from the devices. The system manual recommends to protect access to this port. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. |
A vulnerability has been identified in TIA Administrator (All versions < V1.0 SP1 Upd1). The integrated configuration web application (TIA Administrator) allows to execute certain application commands without proper authentication. The vulnerability could be exploited by an attacker with local access to the affected system. Successful exploitation requires no privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. |
An incorrect access control exists in the Sony Photo Sharing Plus application in the firmware before PKG6.5629 version (for the X7500D TV and other applicable TVs). This vulnerability allows an attacker to read arbitrary files without authentication over HTTP when Photo Sharing Plus application is running. This may allow an attacker to browse a particular directory (e.g. images) inside the private network. |
An issue was discovered in LibreNMS through 1.47. A number of scripts import the Authentication libraries, but do not enforce an actual authentication check. Several of these scripts disclose information or expose functions that are of a sensitive nature and are not expected to be publicly accessible. |
An authentication bypass vulnerability was discovered in foreman-tasks before 0.15.7. Previously, commit tasks were searched through find_resource, which performed authorization checks. After the change to Foreman, an unauthenticated user can view the details of a task through the web UI or API, if they can discover or guess the UUID of the task. |
eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.15 use session IDs for authentication but lack authorization checks. An attacker can obtain a session ID via the user authentication dialogue, aka HMCCU-153. This leads to automatic login as admin. |
eQ-3 HomeMatic CCU2 devices before 2.41.8 and CCU3 devices before 3.43.16 use session IDs for authentication but lack authorization checks. An attacker can obtain a session ID via an invalid login attempt to the RemoteApi account, aka HMCCU-154. This leads to automatic login as admin. |
An unauthenticated attacker can obtain information about the Pydio 8.2.2 configuration including session timeout, libraries, and license information. |
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use an API URL /goform/LoadDefaultSettings to reset the router without authentication. |
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use an API URL /goform/form2userconfig.cgi to edit the system account without authentication. |
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use a hidden API URL /goform/SystemCommand to execute a system command without authentication. |
The D-Link DIR-816 A2 1.11 router only checks the random token when authorizing a goform request. An attacker can get this token from dir_login.asp and use an API URL /goform/setSysAdm to edit the web or system account without authentication. |
ChinaMobile GPN2.4P21-C-CN W2001EN-00 is affected by: Incorrect Access Control - Unauthenticated Remote Reboot. The impact is: PLC Wireless Router's are vulnerable to an unauthenticated remote reboot due. The component is: Reboot settings are available to unauthenticated users instead of only authenticaed users. The attack vector is: Remote. |
GNU Libc current is affected by: Mitigation bypass. The impact is: Attacker may bypass stack guard protection. The component is: nptl. The attack vector is: Exploit stack buffer overflow vulnerability and use this bypass vulnerability to bypass stack guard. NOTE: Upstream comments indicate "this is being treated as a non-security bug and no real threat. |