Search Results (323531 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2022-24336 1 Jetbrains 1 Teamcity 2024-11-21 5.3 Medium
In JetBrains TeamCity before 2021.2.1, an unauthenticated attacker can cancel running builds via an XML-RPC request to the TeamCity server.
CVE-2022-24335 1 Jetbrains 1 Teamcity 2024-11-21 8.1 High
JetBrains TeamCity before 2021.2 was vulnerable to a Time-of-check/Time-of-use (TOCTOU) race-condition attack in agent registration via XML-RPC.
CVE-2022-24334 1 Jetbrains 1 Teamcity 2024-11-21 5.3 Medium
In JetBrains TeamCity before 2021.2.1, the Agent Push feature allowed selection of any private key on the server.
CVE-2022-24333 1 Jetbrains 1 Teamcity 2024-11-21 6.5 Medium
In JetBrains TeamCity before 2021.2, blind SSRF via an XML-RPC call was possible.
CVE-2022-24332 1 Jetbrains 1 Teamcity 2024-11-21 5.3 Medium
In JetBrains TeamCity before 2021.2, a logout action didn't remove a Remember Me cookie.
CVE-2022-24331 1 Jetbrains 1 Teamcity 2024-11-21 9.8 Critical
In JetBrains TeamCity before 2021.1.4, GitLab authentication impersonation was possible.
CVE-2022-24330 1 Jetbrains 1 Teamcity 2024-11-21 6.1 Medium
In JetBrains TeamCity before 2021.2.1, a redirection to an external site was possible.
CVE-2022-24329 2 Jetbrains, Oracle 3 Kotlin, Communications Cloud Native Core Binding Support Function, Communications Pricing Design Center 2024-11-21 5.3 Medium
In JetBrains Kotlin before 1.6.0, it was not possible to lock dependencies for Multiplatform Gradle Projects.
CVE-2022-24328 1 Jetbrains 1 Hub 2024-11-21 6.5 Medium
In JetBrains Hub before 2021.1.13956, an unprivileged user could perform DoS.
CVE-2022-24327 1 Jetbrains 1 Hub 2024-11-21 7.5 High
In JetBrains Hub before 2021.1.13890, integration with JetBrains Account exposed an API key with excessive permissions.
CVE-2022-24323 1 Schneider-electric 2 Ecostruxure Control Expert, Ecostruxure Process Expert 2024-11-21 5.3 Medium
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Process Expert (V2021 and prior), EcoStruxure Control Expert (V15.0 SP1 and prior)
CVE-2022-24322 1 Schneider-electric 1 Ecostruxure Control Expert 2024-11-21 5.3 Medium
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior)
CVE-2022-24321 1 Schneider-electric 3 Clearscada, Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 2024-11-21 7.5 High
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed HTTP request. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)
CVE-2022-24320 1 Schneider-electric 3 Clearscada, Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 2024-11-21 5.9 Medium
A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA database server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)
CVE-2022-24319 1 Schneider-electric 3 Clearscada, Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 2024-11-21 5.9 Medium
A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA web server are intercepted. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)
CVE-2022-24318 1 Schneider-electric 3 Clearscada, Ecostruxure Geo Scada Expert 2019, Ecostruxure Geo Scada Expert 2020 2024-11-21 7.5 High
A CWE-326: Inadequate Encryption Strength vulnerability exists that could cause non-encrypted communication with the server when outdated versions of the ViewX client are used. Affected Product: ClearSCADA (All Versions), EcoStruxure Geo SCADA Expert 2019 (All Versions), EcoStruxure Geo SCADA Expert 2020 (All Versions)
CVE-2022-24317 1 Schneider-electric 1 Interactive Graphical Scada System Data Server 2024-11-21 7.5 High
A CWE-862: Missing Authorization vulnerability exists that could cause information exposure when an attacker sends a specific message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CVE-2022-24316 1 Schneider-electric 1 Interactive Graphical Scada System Data Server 2024-11-21 7.5 High
A CWE-665: Improper Initialization vulnerability exists that could cause information exposure when an attacker sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CVE-2022-24315 1 Schneider-electric 1 Interactive Graphical Scada System Data Server 2024-11-21 7.5 High
A CWE-125: Out-of-bounds Read vulnerability exists that could cause denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)
CVE-2022-24314 1 Schneider-electric 1 Interactive Graphical Scada System Data Server 2024-11-21 7.5 High
A CWE-125: Out-of-bounds Read vulnerability exists that could cause memory leaks potentially resulting in denial of service when an attacker repeatedly sends a specially crafted message. Affected Product: Interactive Graphical SCADA System Data Server (V15.0.0.22020 and prior)