| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A malicious X-ProxyContextPath or X-Forwarded-Context header containing external resources or embedded code could cause remote code execution. The fix to properly handle these headers was applied on the Apache NiFi 1.5.0 release. Users running a prior 1.x release should upgrade to the appropriate release. |
| When an Apache Geode cluster before v1.4.0 is operating in secure mode, the Geode configuration service does not properly authorize configuration requests. This allows an unprivileged user who gains access to the Geode locator to extract configuration data and previously deployed application code. |
| Artifex Ghostscript 9.22 is affected by: Obtain Information. The impact is: obtain sensitive information. The component is: affected source code file, affected function, affected executable, affected libga (imagemagick used that). The attack vector is: Someone must open a postscript file though ghostscript. Because of imagemagick also use libga, so it was affected as well. |
| Symantec SSL Visibility (SSLV) 3.8.4FC, 3.10 prior to 3.10.4.1, 3.11, and 3.12 prior to 3.12.2.1 are vulnerable to the Return of the Bleichenbacher Oracle Threat (ROBOT) attack. All affected SSLV versions act as weak oracles according the oracle classification used in the ROBOT research paper. A remote attacker, who has captured a pre-recorded SSL session inspected by SSLV, can establish multiple millions of crafted SSL connections to the target and obtain the session keys required to decrypt the pre-recorded SSL session. |
| All versions of OnCommand API Services prior to 2.1 and NetApp Service Level Manager prior to 1.0RC4 log a privileged database user account password. All users are urged to move to a fixed version. Since the affected password is changed during every upgrade/installation no further action is required. |
| Insufficient policy enforcement in Omnibox in Google Chrome prior to 63.0.3239.84 allowed a remote attacker to perform domain spoofing via IDN homographs in a crafted domain name. |
| Insufficient policy enforcement in Omnibox in Google Chrome prior to 63.0.3239.84 allowed a remote attacker to perform domain spoofing via IDN homographs in a crafted domain name. |
| Insufficient policy enforcement in Omnibox in Google Chrome prior to 63.0.3239.84 allowed a remote attacker to perform domain spoofing via IDN homographs in a crafted domain name. |
| Incorrect handling of back navigations in error pages in Navigation in Google Chrome prior to 63.0.3239.84 allowed a remote attacker to spoof the contents of the Omnibox (URL bar) via a crafted HTML page. |
| Using an ID that can be controlled by a compromised renderer which allows any frame to overwrite the page_state of any other frame in the same process in Navigation in Google Chrome on Chrome OS prior to 62.0.3202.74 allowed a remote attacker who had compromised the renderer process to potentially perform a sandbox escape via a crafted HTML page. |
| Insufficient Policy Enforcement in Extensions in Google Chrome prior to 62.0.3202.62 allowed a remote attacker to perform domain spoofing in permission dialogs via IDN homographs in a crafted Chrome Extension. |
| Insufficient data validation in V8 in Google Chrome prior to 62.0.3202.62 allowed an attacker who can write to the Windows Registry to potentially exploit heap corruption via a crafted Windows Registry entry, related to PlatformIntegration. |
| Insufficient Policy Enforcement in Omnibox in Google Chrome prior to 62.0.3202.62 allowed a remote attacker to perform domain spoofing via IDN homographs in a crafted domain name. |
| An insufficient watchdog timer in navigation in Google Chrome prior to 62.0.3202.62 allowed a remote attacker to spoof the contents of the Omnibox (URL bar) via a crafted HTML page. |
| Incorrect implementation in Blink in Google Chrome prior to 62.0.3202.62 allowed a remote attacker to spoof the contents of the Omnibox (URL bar) via a crafted HTML page. |
| Huawei IPS Module V500R001C00, NGFW Module V500R001C00, NIP6300 V500R001C00, NIP6600 V500R001C00, Secospace USG6300 V500R001C00, Secospace USG6500 V500R001C00, Secospace USG6600 V500R001C00, USG9500 V500R001C00 have an insufficient input validation vulnerability. An unauthenticated, remote attacker could send specific MPLS Echo Request messages to the target products. Due to insufficient input validation of some parameters in the messages, successful exploit may cause the device to reset. |
| XML parser in Huawei S12700 V200R005C00,S1700 V200R009C00, V200R010C00,S3700 V100R006C03, V100R006C05,S5700 V200R001C00, V200R002C00, V200R003C00, V200R003C02, V200R005C00, V200R006C00, V200R007C00, V200R008C00, V200R009C00, V200R010C00,S6700 V200R001C00, V200R002C00, V200R003C00, V200R005C00, V200R005C02, V200R008C00, V200R009C00, V200R010C00,S7700 V200R001C00, V200R002C00, V200R003C00, V200R005C00, V200R006C00, V200R007C00, V200R008C00, V200R009C00, V200R010C00,S9700 V200R001C00, V200R002C00, V200R003C00, V200R005C00, V200R006C00, V200R007C00, V200R008C00, V200R009C00, V200R010C00,eCNS210_TD V100R004C10, V100R004C10SPC003, V100R004C10SPC100, V100R004C10SPC101, V100R004C10SPC102, V100R004C10SPC200, V100R004C10SPC221, V100R004C10SPC400 has a DOS vulnerability. An attacker may craft specific XML files to the affected products. Due to not check the specially XML file and to parse this file, successful exploit will result in DOS attacks. |
| XML parser in Huawei S12700 V200R005C00,S1700 V200R009C00, V200R010C00,S3700 V100R006C03, V100R006C05,S5700 V200R001C00, V200R002C00, V200R003C00, V200R003C02, V200R005C00, V200R006C00, V200R007C00, V200R008C00, V200R009C00, V200R010C00,S6700 V200R001C00, V200R002C00, V200R003C00, V200R005C00, V200R005C02, V200R008C00, V200R009C00, V200R010C00,S7700 V200R001C00, V200R002C00, V200R003C00, V200R005C00, V200R006C00, V200R007C00, V200R008C00, V200R009C00, V200R010C00,S9700 V200R001C00, V200R002C00, V200R003C00, V200R005C00, V200R006C00, V200R007C00, V200R008C00, V200R009C00, V200R010C00,eCNS210_TD V100R004C10, V100R004C10SPC003, V100R004C10SPC100, V100R004C10SPC101, V100R004C10SPC102, V100R004C10SPC200, V100R004C10SPC221, V100R004C10SPC400 has a DOS vulnerability. An attacker may craft specific XML files to the affected products. Due to not check the specially XML file and to parse this file, successful exploit will result in DOS attacks. |
| S12700 V200R005C00, V200R006C00, V200R006C01, V200R007C00, V200R007C01, V200R007C20, V200R008C00, V200R008C06, V200R009C00, V200R010C00, S7700 V200R001C00, V200R001C01, V200R002C00, V200R003C00, V200R005C00, V200R006C00, V200R006C01, V200R007C00, V200R007C01, V200R008C00, V200R008C06, V200R009C00, V200R010C00, S9700 V200R001C00, V200R001C01, V200R002C00, V200R003C00, V200R005C00, V200R006C00, V200R006C01, V200R007C00, V200R007C01, V200R008C00, V200R009C00, V200R010C00 have an improper authorization vulnerability on Huawei switch products. The system incorrectly performs an authorization check when a normal user attempts to access certain information which is supposed to be accessed only by authenticated user. Successful exploit could cause information disclosure. |
| A vulnerability was found in openstack-cinder releases up to and including Queens, allowing newly created volumes in certain storage volume configurations to contain previous data. It specifically affects ScaleIO volumes using thin volumes and zero padding. This could lead to leakage of sensitive information between tenants. |