SolarView Compact <= 6.0 is vulnerable to Insecure Permissions. Any file on the server can be read or modified because texteditor.php is not restricted.
Search vulnerabilities
Directory traversal vulnerability in MW WP Form versions v4.4.2 and earlier allows a remote unauthenticated attacker to alter the website or cause a denial-of-service (DoS) condition, and obtain sensitive information depending on settings.
D-Link DIR-300 firmware <=REVA1.06 and <=REVB2.06 is vulnerable to File inclusion via /model/__lang_msg.php.
CVE-2023-0432
The web configuration service of the affected device contains an authenticated command injection vulnerability. It can be used to execute system commands on the operating system (OS) from the device in the context of the user "root." If the attacker has credentials for the web service, then the device could be fully compromised.
Authenticated OS Command Injection in Danfoss AK-EM100
The Danfoss AK-EM100 web applications allow for an authenticated user to perform OS command injection through the web application parameters.
Authenticated Remote Command Execution in Danfoss AK-SM800A
Due to improper input validation, an authenticated remote attacker could execute arbitrary commands on the target system.
An improper control of generation of code ('code injection') in Fortinet FortiClientLinux version 7.2.0, 7.0.6 through 7.0.10 and 7.0.3 through 7.0.4 allows attacker to execute unauthorized code or commands via tricking a FortiClientLinux user into visiting a malicious website
CVE-2023-1967
Keysight N8844A Data Analytics Web Service deserializes untrusted data without sufficiently verifying the resulting data will be valid.
InHand Networks InRouter 302, prior to version IR302 V3.5.56, and InRouter 615, prior to version InRouter6XX-S-V2.3.0.r5542, contain vulnerability CWE-284: Improper Access Control. They allow unauthenticated devices to subscribe to MQTT topics on the same network as the device manager. An unauthorized user who knows of an existing topic name could send and receive messages to and from that topic. This includes the ability to send GET/SET configuration commands, reboot commands, and push firmware updates.
InHand Networks InRouter 302, prior to version IR302 V3.5.56, and InRouter 615, prior to version InRouter6XX-S-V2.3.0.r5542, contain vulnerability CWE-330: Use of Insufficiently Random Values. They do not properly randomize MQTT ClientID parameters. An unauthorized user could calculate this parameter and use it to gather additional information about other InHand devices managed on the same cloud platform.
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization.
CVE-2022-41989
Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 does not validate the length of RTLS report payloads during communication. This allows an attacker to send an exceedingly long payload, resulting in an out-of-bounds write to cause a denial-of-service condition or code execution.
CVE-2022-43483
Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 does not properly validate the input module name to the monitor services of the software. This could allow a remote attacker to access sensitive functions of the application and execute arbitrary system commands.
CVE-2022-45444
Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 contains hard-coded passwords for select users in the application’s database. This could allow a remote attacker to login to the database with unrestricted access.
CVE-2022-47911
Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 does not properly validate the input module name to the backup services of the software. This could allow a remote attacker to access sensitive functions of the application and execute arbitrary system commands.
SAUTER Controls Nova 200–220 Series Missing Authentication for Critical Function
SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior allows the execution of commands without credentials. As Telnet and file transfer protocol (FTP) are the only protocols available for device management, an unauthorized user could access the system and modify the device configuration, which could result in the unauthorized user executing unrestricted malicious commands.
Econolite EOS versions prior to 3.2.23 use a weak hash algorithm for encrypting privileged user credentials. A configuration file that is accessible without authentication uses MD5 hashes for encrypting credentials, including those of administrators and technicians.
X-600M Code Injection
Control By Web X-600M devices run Lua scripts and are vulnerable to code injection, which could allow an attacker to remotely execute arbitrary code.
CVE-2023-0102
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication for its deletion command. This could allow an attacker to delete arbitrary files.
CVE-2023-22804
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to create users on the PLC. This could allow an attacker to create and use an account with elevated privileges and take control of the device.