Search Results (30114 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2021-22910 1 Rocket.chat 1 Rocket.chat 2024-11-21 9.8 Critical
A sanitization vulnerability exists in Rocket.Chat server versions <3.13.2, <3.12.4, <3.11.4 that allowed queries to an endpoint which could result in a NoSQL injection, potentially leading to RCE.
CVE-2021-22891 1 Citrix 1 Sharefile Storagezones Controller 2024-11-21 9.8 Critical
A missing authorization vulnerability exists in Citrix ShareFile Storage Zones Controller before 5.7.3, 5.8.3, 5.9.3, 5.10.1 and 5.11.18 may allow unauthenticated remote compromise of the Storage Zones Controller.
CVE-2021-22869 1 Github 1 Enterprise Server 2024-11-21 9.8 Critical
An improper access control vulnerability in GitHub Enterprise Server allowed a workflow job to execute in a self-hosted runner group it should not have had access to. This affects customers using self-hosted runner groups for access control. A repository with access to one enterprise runner group could access all of the enterprise runner groups within the organization because of improper authentication checks during the request. This could cause code to be run unintentionally by the incorrect runner group. This vulnerability affected GitHub Enterprise Server versions from 3.0.0 to 3.0.15 and 3.1.0 to 3.1.7 and was fixed in 3.0.16 and 3.1.8 releases.
CVE-2021-22860 1 Eic 1 E-document System 2024-11-21 9.8 Critical
EIC e-document system does not perform completed identity verification for sorting and filtering personnel data. The vulnerability allows remote attacker to obtain users’ credential information without logging in the system, and further acquire the privileged permissions and execute arbitrary commends.
CVE-2021-22859 1 Eic 1 E-document System 2024-11-21 9.8 Critical
The users’ data querying function of EIC e-document system does not filter the special characters which resulted in remote attackers can inject SQL syntax and execute arbitrary commands without privilege.
CVE-2021-22856 1 Changjia Property Management System Project 1 Changjia Property Management System 2024-11-21 9.8 Critical
The CGE property management system contains SQL Injection vulnerabilities. Remote attackers can inject SQL commands into the parameters in Cookie and obtain data in the database without privilege.
CVE-2021-22855 1 Hr Portal Project 1 Hr Portal 2024-11-21 9.8 Critical
The specific function of HR Portal of Soar Cloud System accepts any type of object to be deserialized. Attackers can send malicious serialized objects to execute arbitrary commands.
CVE-2021-22851 1 Hgiga 1 Oaklouds Openid 2024-11-21 9.8 Critical
HGiga EIP product contains SQL Injection vulnerability. Attackers can inject SQL commands into specific URL parameter (document management page) to obtain database schema and data.
CVE-2021-22823 1 Schneider-electric 1 Interactive Graphical Scada System Data Collector 2024-11-21 9.1 Critical
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21320 and prior)
CVE-2021-22820 1 Schneider-electric 12 Evlink City Evc1s22p4, Evlink City Evc1s22p4 Firmware, Evlink City Evc1s7p4 and 9 more 2024-11-21 9.8 Critical
A CWE-614 Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain an unauthorized access over a hijacked session to the charger station web server even after the legitimate user account holder has changed his password. Affected Products: EVlink City EVC1S22P4 / EVC1S7P4 (All versions prior to R8 V3.4.0.2 ), EVlink Parking EVW2 / EVF2 / EVP2PE (All versions prior to R8 V3.4.0.2), and EVlink Smart Wallbox EVB1A (All versions prior to R8 V3.4.0.2)
CVE-2021-22805 1 Schneider-electric 1 Interactive Graphical Scada System Data Collector 2024-11-21 9.1 Critical
A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IGSS due to lack of validation of network messages. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
CVE-2021-22803 1 Schneider-electric 1 Interactive Graphical Scada System Data Collector 2024-11-21 9.8 Critical
A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could lead to remote code execution through a number of paths, when an attacker, writes arbitrary files to folders in context of the DC module, by sending constructed messages on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
CVE-2021-22802 1 Schneider-electric 1 Interactive Graphical Scada System Data Collector 2024-11-21 9.8 Critical
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user supplied data, when a constructed message is received on the network. Affected Product: Interactive Graphical SCADA System Data Collector (dc.exe) (V15.0.0.21243 and prior)
CVE-2021-22801 1 Schneider-electric 1 Connexium Network Manager 2024-11-21 9.8 Critical
A CWE-269: Improper Privilege Management vulnerability exists that could cause an arbitrary command execution when the software is configured with specially crafted event actions. Affected Product: ConneXium Network Manager Software (All Versions)
CVE-2021-22795 1 Schneider-electric 1 Struxureware Data Center Expert 2024-11-21 9.1 Critical
A CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote code execution when performed over the network. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)
CVE-2021-22794 1 Schneider-electric 1 Struxureware Data Center Expert 2024-11-21 9.1 Critical
A CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution. Affected Product: StruxureWare Data Center Expert (V7.8.1 and prior)
CVE-2021-22772 1 Schneider-electric 6 T200e, T200e Firmware, T200i and 3 more 2024-11-21 9.8 Critical
A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T200 ((Modbus) SC2-04MOD-07000100 and earlier), Easergy T200 ((IEC104) SC2-04IEC-07000100 and earlier), and Easergy T200 ((DNP3) SC2-04DNP-07000102 and earlier) that could cause unauthorized operation when authentication is bypassed.
CVE-2021-22767 1 Schneider-electric 4 Powerlogic Egx100, Powerlogic Egx100 Firmware, Powerlogic Egx300 and 1 more 2024-11-21 9.8 Critical
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-2276
CVE-2021-22738 1 Schneider-electric 4 Homelynk, Homelynk Firmware, Spacelynk and 1 more 2024-11-21 9.8 Critical
Use of a Broken or Risky Cryptographic Algorithm vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access when credentials are discovered after a brute force attack.
CVE-2021-22737 1 Schneider-electric 4 Homelynk, Homelynk Firmware, Spacelynk and 1 more 2024-11-21 9.8 Critical
Insufficiently Protected Credentials vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access of when credentials are discovered after a brute force attack.