Search vulnerabilities

Results 426,000

CVE-2021-32937

MDT AutoSave Generation of Error Message Containing Sensitive Information

An attacker can gain knowledge of a session temporary working folder where the getfile and putfile commands are used in MDT AutoSave versions prior to v6.02.06. An attacker can leverage this knowledge to provide a malicious command to the working directory where the read and write activity can be initiated.

CVSS 3.1 · 7.5 High EPSS 1.1% KEV · Not listed
Vendors
CVE-2021-32957

MDT AutoSave Uncontrolled Search Path Element

A function in MDT AutoSave versions prior to v6.02.06 is used to retrieve system information for a specific process, and this information collection executes multiple commands and summarizes the information into an XML. This function and subsequent process gives full path to the executable and is therefore vulnerable to binary hijacking.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
CVE-2021-32949

MDT AutoSave Relative Path Traversal

An attacker could utilize a function in MDT AutoSave versions prior to v6.02.06 that permits changing a designated path to another path and traversing the directory, allowing the replacement of an existing file with a malicious file.

CVSS 3.1 · 7.5 High EPSS 1.1% KEV · Not listed
Vendors
CVE-2021-32976

Moxa NPort IAW5000A-I/O Series Serial Device Server Stack-based Buffer Overflow

Five buffer overflows in the built-in web server in Moxa NPort IAW5000A-I/O series firmware version 2.2 or earlier may allow a remote attacker to initiate a denial-of-service attack and execute arbitrary code.

CVSS 3.1 · 9.8 Critical EPSS 2.8% KEV · Not listed
Vendors
CVE-2021-33020

Philips Vue PACS Use of a Key Past its Expiration Date

Philips Vue PACS versions 12.2.x.x and prior uses a cryptographic key or password past its expiration date, which diminishes its safety significantly by increasing the timing window for cracking attacks against that key.

CVSS 3.1 · 8.2 High EPSS < 1% KEV · Not listed
Vendors
Products
Myvue Speech Vue Motion and 1 more
CVE-2021-33024

Philips Vue PACS Insufficiently Protected Credentials

Philips Vue PACS versions 12.2.x.x and prior transmits or stores authentication credentials, but it uses an insecure method susceptible to unauthorized interception and/or retrieval.

CVSS 3.1 · 3.7 Low EPSS < 1% KEV · Not listed
Vendors
Products
Myvue Speech Vue Motion and 1 more
CVE-2021-33022

Philips Vue PACS Cleartext Transmission of Sensitive Information

Philips Vue PACS versions 12.2.x.x and prior transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors.

CVSS 3.1 · 7.5 High EPSS < 1% KEV · Not listed
Vendors
Products
Myvue Speech Vue Motion and 1 more
CVE-2022-1018

ICSA-22-088-01 Rockwell Automation ISaGRAF

When opening a malicious solution file provided by an attacker, the application suffers from an XML external entity vulnerability due to an unsafe call within a dynamic link library file. An attacker could exploit this to pass data from local files to a remote web server, leading to a loss of confidentiality.

CVSS 3.1 · 5.5 Medium EPSS 2.2% KEV · Not listed
CVE-2020-14479

ICSA-20-147-01 Inductive Automation Ignition (Update B)

Sensitive information can be obtained through the handling of serialized data. The issue results from the lack of proper authentication required to query the server

CVSS 3.1 · 5.3 Medium EPSS < 1% KEV · Not listed
Products
CVE-2022-1068

Modbus Tools Modbus Slave Stack-Based Buffer Overflow

Modbus Tools Modbus Slave (versions 7.4.2 and prior) is vulnerable to a stack-based buffer overflow in the registration field. This may cause the program to crash when a long character string is used.

CVSS 3.1 · 5.5 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2021-33010

AVEVA System Platform Uncaught Exception

An exception is thrown from a function in AVEVA System Platform versions 2017 through 2020 R2 P01, but it is not caught, which may cause a denial-of-service condition.

CVSS 3.1 · 7.5 High EPSS 1.1% KEV · Not listed
Vendors
Products
CVE-2021-32980

Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel

Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 does not protect against additional software programming connections. An attacker can connect to the PLC while an existing connection is already active.

CVSS 3.1 · 9.8 Critical EPSS 1.1% KEV · Not listed
CVE-2021-32978

Automation Direct CLICK PLC CPU Modules Plaintext Storage of a Password

The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was successful, the attacker can then use the password to unlock Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00.

CVSS 3.1 · 7.5 High EPSS 1.0% KEV · Not listed
CVE-2021-32984

Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel

All programming connections receive the same unlocked privileges, which can result in a privilege escalation. During the time Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, an attacker can connect to the PLC and read the project without authorization.

CVSS 3.1 · 9.8 Critical EPSS 1.1% KEV · Not listed
CVE-2021-32986

Automation Direct CLICK PLC CPU Modules Authentication Bypass Using an Alternate Path or Channel

After Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 is unlocked by an authorized user, the unlocked state does not timeout. If the programming software is interrupted, the PLC remains unlocked. All subsequent programming connections are allowed without authorization. The PLC is only relocked by a power cycle, or when the programming software disconnects correctly.

CVSS 3.1 · 9.8 Critical EPSS 1.1% KEV · Not listed