Search Results (371925 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-36376 1 Jetbrains 1 Teamcity 2025-01-27 6.5 Medium
In JetBrains TeamCity before 2024.03.2 users could perform actions that should not be available to them based on their permissions
CVE-2024-28971 1 Dell 1 Openmanage Enterprise Update Manager 2025-01-27 3.5 Low
Dell Update Manager Plugin, versions 1.4.0 through 1.5.0, contains a Plain-text Password Storage Vulnerability in Log file. A remote high privileged attacker could potentially exploit this vulnerability, leading to the disclosure of certain user credentials. The attacker may be able to use the exposed credentials to access the vulnerable application with privileges of the compromised account.
CVE-2024-36375 1 Jetbrains 1 Teamcity 2025-01-27 5.3 Medium
In JetBrains TeamCity before 2024.03.2 technical information regarding TeamCity server could be exposed
CVE-2024-36374 1 Jetbrains 1 Teamcity 2025-01-27 4.6 Medium
In JetBrains TeamCity before 2024.03.2 stored XSS via build step settings was possible
CVE-2024-36373 1 Jetbrains 1 Teamcity 2025-01-27 4.6 Medium
In JetBrains TeamCity before 2024.03.2 several stored XSS in untrusted builds settings were possible
CVE-2024-36372 1 Jetbrains 1 Teamcity 2025-01-27 4.6 Medium
In JetBrains TeamCity before 2023.05.6 reflected XSS on the subscriptions page was possible
CVE-2024-4491 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability classified as critical was found in Tenda i21 1.0.0.14(4656). This vulnerability affects the function formGetDiagnoseInfo. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263080. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4492 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). This issue affects the function formOfflineSet of the file /goform/setStaOffline. The manipulation of the argument GO/ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263081 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4493 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). Affected is the function formSetAutoPing. The manipulation of the argument ping1/ping2 leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-263082 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4494 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this vulnerability is the function formSetUplinkInfo of the file /goform/setUplinkInfo. The manipulation of the argument pingHostIp2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263083. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4495 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this issue is the function formWifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263084. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4496 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. This affects the function formWifiMacFilterSet. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263085 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2023-1732 1 Cloudflare 1 Circl 2025-01-27 5.3 Medium
When sampling randomness for a shared secret, the implementation of Kyber and FrodoKEM, did not check whether crypto/rand.Read() returns an error. In rare deployment cases (error thrown by the Read() function), this could lead to a predictable shared secret. The tkn20 and blindrsa components did not check whether enough randomness was returned from the user provided randomness source. Typically the user provides crypto/rand.Reader, which in the vast majority of cases will always return the right number random bytes. In the cases where it does not, or the user provides a source that does not, the blinding for blindrsa is weak and integrity of the plaintext is not ensured in tkn20.
CVE-2023-32076 1 In-toto Project 1 In-toto 2025-01-27 5.5 Medium
in-toto is a framework to protect supply chain integrity. The in-toto configuration is read from various directories and allows users to configure the behavior of the framework. The files are from directories following the XDG base directory specification. In versions 1.4.0 and prior, among the files read is `.in_totorc` which is a hidden file in the directory in which in-toto is run. If an attacker controls the inputs to a supply chain step, they can mask their activities by also passing in an `.in_totorc` file that includes the necessary exclude patterns and settings. RC files are widely used in other systems and security issues have been discovered in their implementations as well. Maintainers found in their conversations with in-toto adopters that `in_totorc` is not their preferred way to configure in-toto. As none of the options supported in `in_totorc` is unique, and can be set elsewhere using API parameters or CLI arguments, the maintainers decided to drop support for `in_totorc`. in-toto's `user_settings` module has been dropped altogether in commit 3a21d84f40811b7d191fa7bd17265c1f99599afd. Users may also sandbox functionary code as a security measure.
CVE-2024-28781 1 Ibm 2 Devops Deploy, Urbancode Deploy 2025-01-27 5.4 Medium
IBM UrbanCode Deploy (UCD) 7.0 through 7.0.5.20, 7.1 through 7.1.2.16, 7.2 through 7.2.3.9, 7.3 through 7.3.2.4, and 8.0 through 8.0.0.1 is vulnerable to cross-site scripting. This vulnerability allows users to embed arbitrary JavaScript code in the Web UI thus altering the intended functionality potentially leading to credentials disclosure within a trusted session. IBM X-Force ID: 285654.
CVE-2024-4237 1 Tenda 2 Ax1806, Ax1806 Firmware 2025-01-27 8.8 High
A vulnerability, which was classified as critical, was found in Tenda AX1806 1.0.0.1. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262128. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4238 1 Tenda 2 Ax1806, Ax1806 Firmware 2025-01-27 8.8 High
A vulnerability has been found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this vulnerability is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262129 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4239 1 Tenda 2 Ax1806, Ax1806 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262130 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4240 1 Tenda 2 W9, W9 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. This affects the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4241 1 Tenda 2 W9, W9 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. This vulnerability affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-262132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.