CVE Vendors Products Updated CVSS v3.1
CVE-2020-7602 1 Node-prompt-here Project 1 Node-prompt-here 2024-11-21 9.8 Critical
node-prompt-here through 1.0.1 allows execution of arbitrary commands. The "runCommand()" is called by "getDevices()" function in file "linux/manager.js", which is required by the "index. process.env.NM_CLI" in the file "linux/manager.js". This function is used to construct the argument of function "execSync()", which can be controlled by users without any sanitization.
CVE-2020-7601 1 Gulp-scss-lint Project 1 Gulp-scss-lint 2024-11-21 9.8 Critical
gulp-scss-lint through 1.0.0 allows execution of arbitrary commands. It is possible to inject arbitrary commands to the "exec" function located in "src/command.js" via the provided options.
CVE-2020-7593 1 Siemens 2 Logo\! 8 Bm, Logo\! 8 Bm Firmware 2024-11-21 9.8 Critical
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (V1.81.01 - V1.81.03), LOGO! 8 BM (incl. SIPLUS variants) (V1.82.01), LOGO! 8 BM (incl. SIPLUS variants) (V1.82.02). A buffer overflow vulnerability exists in the Web Server functionality of the device. A remote unauthenticated attacker could send a specially crafted HTTP request to cause a memory corruption, potentially resulting in remote code execution.
CVE-2020-7589 1 Siemens 2 Logo\! 8 Bm, Logo\! 8 Bm Firmware 2024-11-21 9.1 Critical
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions). The vulnerability could lead to an attacker reading and modifying the device configuration and obtain project files from affected devices. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 135/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality, integrity, and availability of the device. At the time of advisory publication no public exploitation of this security vulnerability was known.
CVE-2020-7561 1 Schneider-electric 2 Easergy T300, Easergy T300 Firmware 2024-11-21 9.8 Critical
A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T300 (with firmware 2.7 and older) that could cause a wide range of problems, including information exposure, denial of service, and command execution when access to a resource from an attacker is not restricted or incorrectly restricted.
CVE-2020-7548 1 Schneider-electric 14 Acti9 Powertag Link, Acti9 Powertag Link Firmware, Acti9 Powertag Link Hd and 11 more 2024-11-21 9.8 Critical
A CWE-330 - Use of Insufficiently Random Values vulnerability exists in Smartlink, PowerTag, and Wiser Series Gateways (see security notification for version information) that could allow unauthorized users to login.
CVE-2020-7540 1 Schneider-electric 46 140cpu65150, 140cpu65150 Firmware, 140cpu65160 and 43 more 2024-11-21 9.8 Critical
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.
CVE-2020-7522 1 Schneider-electric 1 Apc Easy Ups Online Software 2024-11-21 9.8 Critical
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in SFAPV9601 - APC Easy UPS On-Line Software (V2.0 and earlier) when accessing a vulnerable method of `SoundUploadServlet` which may lead to uploading executable files to non-specified directories.
CVE-2020-7521 1 Schneider-electric 1 Apc Easy Ups Online Software 2024-11-21 9.8 Critical
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in SFAPV9601 - APC Easy UPS On-Line Software (V2.0 and earlier) when accessing a vulnerable method of `FileUploadServlet` which may lead to uploading executable files to non-specified directories.
CVE-2020-7512 1 Schneider-electric 2 Easergy T300, Easergy T300 Firmware 2024-11-21 9.8 Critical
A CWE-1103: Use of Platform-Dependent Third Party Components with vulnerabilities vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to exploit the component.
CVE-2020-7508 1 Schneider-electric 2 Easergy T300, Easergy T300 Firmware 2024-11-21 9.8 Critical
A CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists in Easergy T300 (Firmware version 1.5.2 and older) which could allow an attacker to gain full access by brute force.
CVE-2020-7500 1 Schneider-electric 12 Mtn6260-0310, Mtn6260-0310 Firmware, Mtn6260-0315 and 9 more 2024-11-21 9.8 Critical
A CWE-89:Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability exists in U.motion Servers and Touch Panels (affected versions listed in the security notification) which could cause arbitrary code to be executed when a malicious command is entered.
CVE-2020-7498 1 Schneider-electric 2 Os Loader, Unity Loader 2024-11-21 9.8 Critical
A CWE-798: Use of Hard-coded Credentials vulnerability exists in the Unity Loader and OS Loader Software (all versions). The fixed credentials are used to simplify file transfer. Today the use of fixed credentials is considered a vulnerability, which could cause unauthorized access to the file transfer service provided by the Modicon PLCs. This could result in various unintended results.
CVE-2020-7497 1 Schneider-electric 1 Ecostruxure Operator Terminal Expert 2024-11-21 9.8 Critical
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in EcoStruxure Operator Terminal Expert 3.1 Service Pack 1 and prior (formerly known as Vijeo XD)which could cause arbitrary application execution when the computer starts.
CVE-2020-7487 1 Schneider-electric 11 Ecostruxure Machine Expert, Modicon M218, Modicon M218 Firmware and 8 more 2024-11-21 9.8 Critical
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers.
CVE-2020-7485 2 Microsoft, Schneider-electric 4 Windows 7, Windows Nt, Windows Xp and 1 more 2024-11-21 9.8 Critical
**VERSION NOT SUPPORTED WHEN ASSIGNED** A legacy support account in the TriStation software version v4.9.0 and earlier could cause improper access to the TriStation host machine. This was addressed in TriStation version v4.9.1 and v4.10.1 released on May 30, 2013.1
CVE-2020-7480 1 Schneider-electric 22 Andover Continuum 5720, Andover Continuum 5720 Firmware, Andover Continuum 5740 and 19 more 2024-11-21 9.8 Critical
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists in Andover Continuum (All versions), which could cause files on the application server filesystem to be viewable when an attacker interferes with an application's processing of XML data.
CVE-2020-7475 1 Schneider-electric 6 Ecostruxure Control Expert, Modicon M340, Modicon M340 Firmware and 3 more 2024-11-21 9.8 Critical
A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller.
CVE-2020-7472 1 Sugarcrm 1 Sugarcrm 2024-11-21 9.8 Critical
An authorization bypass and PHP local-file-include vulnerability in the installation component of SugarCRM before 8.0, 8.0 before 8.0.7, 9.0 before 9.0.4, and 10.0 before 10.0.0 allows for unauthenticated remote code execution against a configured SugarCRM instance via crafted HTTP requests. (This is exploitable even after installation is completed.).
CVE-2020-7471 1 Djangoproject 1 Django 2024-11-21 9.8 Critical
Django 1.11 before 1.11.28, 2.2 before 2.2.10, and 3.0 before 3.0.3 allows SQL Injection if untrusted data is used as a StringAgg delimiter (e.g., in Django applications that offer downloads of data as a series of rows with a user-specified column delimiter). By passing a suitably crafted delimiter to a contrib.postgres.aggregates.StringAgg instance, it was possible to break escaping and inject malicious SQL.