Filtered by vendor Rockwellautomation Subscriptions
Total 267 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2023-5908 4 Ge, Ptc, Rockwellautomation and 1 more 8 Industrial Gateway Server, Keepserverex, Opc-aggregator and 5 more 2024-08-02 9.1 Critical
KEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information.
CVE-2023-3595 1 Rockwellautomation 24 1756-en2f Series A, 1756-en2f Series A Firmware, 1756-en2f Series B and 21 more 2024-08-02 9.8 Critical
Where this vulnerability exists in the Rockwell Automation 1756 EN2* and 1756 EN3* ControlLogix communication products, it could allow a malicious user to perform remote code execution with persistence on the target system through maliciously crafted CIP messages. This includes the ability to modify, deny, and exfiltrate data passing through the device.
CVE-2023-3596 1 Rockwellautomation 6 1756-en4tr, 1756-en4tr Firmware, 1756-en4trk and 3 more 2024-08-02 7.5 High
Where this vulnerability exists in the Rockwell Automation 1756-EN4* Ethernet/IP communication products, it could allow a malicious user to cause a denial of service by asserting the target system through maliciously crafted CIP messages.
CVE-2023-2917 1 Rockwellautomation 1 Thinmanager Thinserver 2024-08-02 9.8 Critical
The Rockwell Automation Thinmanager Thinserver is impacted by an improper input validation vulnerability.  Due to an improper input validation, a path traversal vulnerability exists, via the filename field, when the ThinManager processes a certain function. If exploited, an unauthenticated remote attacker can upload arbitrary files to any directory on the disk drive where ThinServer.exe is installed.  A malicious user could exploit this vulnerability by sending a crafted synchronization protocol message and potentially gain remote code execution abilities.
CVE-2023-2914 1 Rockwellautomation 1 Thinmanager Thinserver 2024-08-02 7.5 High
The Rockwell Automation Thinmanager Thinserver is impacted by an improper input validation vulnerability, an integer overflow condition exists in the affected products. When the ThinManager processes incoming messages, a read access violation occurs and terminates the process. A malicious user could exploit this vulnerability by sending a crafted synchronization protocol message and causing a denial of service condition in the software.
CVE-2023-2913 1 Rockwellautomation 1 Thinmanager 2024-08-02 7.5 High
An executable used in Rockwell Automation ThinManager ThinServer can be configured to enable an API feature in the HTTPS Server Settings. This feature is disabled by default. When the API is enabled and handling requests, a path traversal vulnerability exists that allows a remote actor to leverage the privileges of the server’s file system and read arbitrary files stored in it. A malicious user could exploit this vulnerability by executing a path that contains manipulating variables.
CVE-2023-2915 1 Rockwellautomation 1 Thinmanager Thinserver 2024-08-02 7.5 High
The Rockwell Automation Thinmanager Thinserver is impacted by an improper input validation vulnerability, Due to improper input validation, a path traversal vulnerability exists when the ThinManager software processes a certain function. If exploited, an unauthenticated remote threat actor can delete arbitrary files with system privileges. A malicious user could exploit this vulnerability by sending a specifically crafted synchronization protocol message resulting in a denial-of-service condition.
CVE-2023-2778 1 Rockwellautomation 1 Factorytalk Transaction Manager 2024-08-02 7.5 High
A denial-of-service vulnerability exists in Rockwell Automation FactoryTalk Transaction Manager. This vulnerability can be exploited by sending a modified packet to port 400. If exploited, the application could potentially crash or experience a high CPU or memory usage condition, causing intermittent application functionality issues. The application would need to be restarted to recover from the DoS.
CVE-2023-2746 1 Rockwellautomation 1 Enhanced Him 2024-08-02 9.6 Critical
The Rockwell Automation Enhanced HIM software contains an API that the application uses that is not protected sufficiently and uses incorrect Cross-Origin Resource Sharing (CORS) settings and, as a result, is vulnerable to a Cross Site Request Forgery (CSRF) attack. To exploit this vulnerability, a malicious user would have to convince a user to click on an untrusted link through a social engineering attack or successfully perform a Cross Site Scripting Attack (XSS). Exploitation of a CSRF could potentially lead to sensitive information disclosure and full remote access to the affected products.
CVE-2023-2637 1 Rockwellautomation 2 Factorytalk Policy Manager, Factorytalk System Services 2024-08-02 7.3 High
Rockwell Automation's FactoryTalk System Services uses a hard-coded cryptographic key to generate administrator cookies.  Hard-coded cryptographic key may lead to privilege escalation.  This vulnerability may allow a local, authenticated non-admin user to generate an invalid administrator cookie giving them administrative privileges to the FactoryTalk Policy Manger database. This may allow the threat actor to make malicious changes to the database that will be deployed when a legitimate FactoryTalk Policy Manager user deploys a security policy model. User interaction is required for this vulnerability to be successfully exploited.
CVE-2023-2639 1 Rockwellautomation 2 Factorytalk Policy Manager, Factorytalk System Services 2024-08-02 4.1 Medium
The underlying feedback mechanism of Rockwell Automation's FactoryTalk System Services that transfers the FactoryTalk Policy Manager rules to relevant devices on the network does not verify that the origin of the communication is from a legitimate local client device.  This may allow a threat actor to craft a malicious website that, when visited, will send a malicious script that can connect to the local WebSocket endpoint and wait for events as if it was a valid client device. If successfully exploited, this would allow a threat actor to receive information including whether FactoryTalk Policy Manager is installed and potentially the entire security policy. 
CVE-2023-2638 1 Rockwellautomation 2 Factorytalk Policy Manager, Factorytalk System Services 2024-08-02 5.9 Medium
Rockwell Automation's FactoryTalk System Services does not verify that a backup configuration archive is password protected.   Improper authorization in FTSSBackupRestore.exe may lead to the loading of malicious configuration archives.  This vulnerability may allow a local, authenticated non-admin user to craft a malicious backup archive, without password protection, that will be loaded by FactoryTalk System Services as a valid backup when a restore procedure takes places. User interaction is required for this vulnerability to be successfully exploited.
CVE-2023-2443 1 Rockwellautomation 1 Thinmanager 2024-08-02 7.5 High
Rockwell Automation ThinManager product allows the use of medium strength ciphers.  If the client requests an insecure cipher, a malicious actor could potentially decrypt traffic sent between the client and server API.
CVE-2023-2444 1 Rockwellautomation 1 Factorytalk Vantagepoint 2024-08-02 7.1 High
A cross site request forgery vulnerability exists in Rockwell Automation's FactoryTalk Vantagepoint. This vulnerability can be exploited in two ways. If an attacker sends a malicious link to a computer that is on the same domain as the FactoryTalk Vantagepoint server and a user clicks the link, the attacker could impersonate the legitimate user and send requests to the affected product.  Additionally, if an attacker sends an untrusted link to a computer that is not on the same domain as the server and a user opens the FactoryTalk Vantagepoint website, enters credentials for the FactoryTalk Vantagepoint server, and clicks on the malicious link a cross site request forgery attack would be successful as well.
CVE-2023-2423 1 Rockwellautomation 2 Armor Powerflex, Armor Powerflex Firmware 2024-08-02 8.6 High
A vulnerability was discovered in the Rockwell Automation Armor PowerFlex device when the product sends communications to the local event log. Threat actors could exploit this vulnerability by sending an influx of network commands, causing the product to generate an influx of event log traffic at a high rate. If exploited, the product would stop normal operations and self-reset creating a denial-of-service condition. The error code would need to be cleared prior to resuming normal operations.
CVE-2023-2262 1 Rockwellautomation 66 1756-en2f Series A, 1756-en2f Series A Firmware, 1756-en2f Series B and 63 more 2024-08-02 9.8 Critical
A buffer overflow vulnerability exists in the Rockwell Automation select 1756-EN* communication devices. If exploited, a threat actor could potentially leverage this vulnerability to perform a remote code execution. To exploit this vulnerability, a threat actor would have to send a maliciously crafted CIP request to device.
CVE-2023-2263 1 Rockwellautomation 2 Kinetix 5700, Kinetix 5700 Firmware 2024-08-02 7.5 High
The Rockwell Automation Kinetix 5700 DC Bus Power Supply Series A is vulnerable to CIP fuzzing.  The new ENIP connections cannot be established if impacted by this vulnerability,  which prohibits operational capabilities of the device resulting in a denial-of-service attack.
CVE-2023-2071 1 Rockwellautomation 2 Factorytalk View, Panelview Plus 2024-08-02 9.8 Critical
Rockwell Automation FactoryTalk View Machine Edition on the PanelView Plus, improperly verifies user’s input, which allows unauthenticated attacker to achieve remote code executed via crafted malicious packets.  The device has the functionality, through a CIP class, to execute exported functions from libraries.  There is a routine that restricts it to execute specific functions from two dynamic link library files.  By using a CIP class, an attacker can upload a self-made library to the device which allows the attacker to bypass the security check and execute any code written in the function.
CVE-2023-2072 1 Rockwellautomation 2 Powermonitor 1000, Powermonitor 1000 Firmware 2024-08-02 8.8 High
The Rockwell Automation PowerMonitor 1000 contains stored cross-site scripting vulnerabilities within the web page of the product.  The vulnerable pages do not require privileges to access and can be injected with code by an attacker which could be used to leverage an attack on an authenticated user resulting in remote code execution and potentially the complete loss of confidentiality, integrity, and availability of the product.
CVE-2023-1834 1 Rockwellautomation 2 Kinetix 5500, Kinetix 5500 Firmware 2024-08-02 9.4 Critical
Rockwell Automation was made aware that Kinetix 5500 drives, manufactured between May 2022 and January 2023, and are running v7.13 may have the telnet and FTP ports open by default.  This could potentially allow attackers unauthorized access to the device through the open ports.