| xmlParseBalancedChunkMemoryRecover in parser.c in libxml2 before 2.9.10 has a memory leak related to newDoc->oldNs. |
| The VRRP parser in tcpdump before 4.9.3 has a buffer over-read in print-vrrp.c:vrrp_print() for VRRP version 3, a different vulnerability than CVE-2018-14463. |
| lmp_print_data_link_subobjs() in print-lmp.c in tcpdump before 4.9.3 lacks certain bounds checks. |
| sf-pcapng.c in libpcap before 1.9.1 does not properly validate the PHB header length before allocating memory. |
| In the GNU C Library (aka glibc or libc6) through 2.28, attempting to resolve a crafted hostname via getaddrinfo() leads to the allocation of a socket descriptor that is not closed. This is related to the if_nametoindex() function. |
| An issue was discovered in Logpoint before 7.7.0. Sensitive information is exposed in System Processes for an extended period during high CPU load. |
| Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterPasswords()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter. |
| Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'SetUserPassword()' function, the 'newPassword' parameter is directly embedded in a shell command string using 'sprintf()' without any sanitisation or validation, and then executed using 'system()'. This allows an attacker to inject arbitrary shell commands that will be executed with the same privileges as the application. |
| An issue was discovered in Logpoint before 7.7.0. An improperly configured access control policy exposes sensitive Logpoint internal service (Redis) information to li-admin users. This can lead to privilege escalation. |
| Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'ShowMeterDatabase()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the 'meter' parameter. |
| Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The vulnerability is found in the 'AddEvent()' function when copying the user-controlled username input to a fixed-size buffer (48 bytes) without boundary checking. This can lead to memory corruption, resulting in possible remote code execution. |
| Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The 'ShowDownload()' function uses “sprintf()” to format a string that includes the user-controlled input of 'GetParameter(meter)' in the fixed-size buffer 'acStack_4c' (64 bytes) without checking the length. An attacker can provide an excessively long value for the 'meter' parameter that exceeds the 64-byte buffer size. |
| Use of hardcoded cryptographic keys in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. The affected firmware contains a hardcoded static authentication key. An attacker with local access to the device can extract this key (e.g., by analysing the firmware image or memory dump) and create valid firmware update packages. This bypasses all intended access controls and grants full administrative privileges. |
| An issue was discovered in Logpoint before 7.7.0. Insufficient input validation and a lack of output escaping in multiple components leads to a cross-site scripting (XSS) vulnerability. |
| Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'showMeterReport()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the “meter” parameter. |
| Stack-based buffer overflow vulnerability in CircutorSGE-PLC1000/SGE-PLC50 v9.0.2. The 'SetLan' function is invoked when a new configuration is applied. This new configuration function is activated by a management web request, which can be invoked by a user when making changes to the 'index.cgi' web application. The parameters are not being sanitised, which could lead to command injection. |
| Stack-based buffer overflow in Circutor SGE-PLC1000/SGE-PLC50 v0.9.2. This vulnerability allows an attacker to remotely exploit memory corruption through the 'read_packet()' function of the TACACSPLUS implementation. |
| Snipe-IT before 8.3.4 allows stored XSS via the Locations "Country" field, enabling a low-privileged authenticated user to inject JavaScript that executes in another user's session. |
| Grav is a file-based Web platform. Prior to 1.8.0-beta.27, users with read access on the user account management section of the admin panel can view the password hashes of all users, including the admin user. This exposure can potentially lead to privilege escalation if an attacker can crack these password hashes. This vulnerability is fixed in 1.8.0-beta.27. |
| WebAssembly Micro Runtime (WAMR) is a lightweight standalone WebAssembly (Wasm) runtime. Prior to version 2.4.4, WAMR is susceptible to a segmentation fault in v128.store instruction. This issue has been patched in version 2.4.4. |