| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Cross Site Scripting (XSS) vulnerability in Joplin Desktop App before 1.8.5 allows attackers to execute aribrary code due to improper sanitizing of html. |
| In elfutils 0.183, an infinite loop was found in the function handle_symtab in readelf.c .Which allows attackers to cause a denial of service (infinite loop) via crafted file. |
| Panorama Tools libpano13 v2.9.20 was discovered to contain an out-of-bounds read in the function panoParserFindOLine() in parser.c. |
| In NTFS-3G versions < 2021.8.22, when a specially crafted MFT section is supplied in an NTFS image a heap buffer overflow can occur and allow for code execution. |
| In NTFS-3G versions < 2021.8.22, when a specially crafted unicode string is supplied in an NTFS image a heap buffer overflow can occur and allow for code execution. |
| D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_80040af8 in /formWlanSetup. This vulnerability is triggered via a crafted POST request. |
| D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function sub_80046EB4 in /formSetPortTr. This vulnerability is triggered via a crafted POST request. |
| D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_800462c4 in /formAdvFirewall. This vulnerability is triggered via a crafted POST request. |
| D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_8004776c in /formVirtualServ. This vulnerability is triggered via a crafted POST request. |
| D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function sub_8003183C in /fromLogin. This vulnerability is triggered via a crafted POST request. |
| D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_80034d60 in /formStaticDHCP. This vulnerability is triggered via a crafted POST request. |
| D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_8004776c in /formVirtualApp. This vulnerability is triggered via a crafted POST request. |
| D-Link DIR-809 devices with firmware through DIR-809Ax_FW1.12WWB03_20190410 were discovered to contain a stack buffer overflow vulnerability in the function FUN_80046eb4 in /formSetPortTr. This vulnerability is triggered via a crafted POST request. |
| Several web interfaces in D-Link DIR-868LW 1.12b have no authentication requirements for access, allowing for attackers to obtain users' DNS query history. |
| A CSV injection vulnerability on the login panel of ManageEngine ADSelfService Plus Version: 6.1 Build No: 6101 can be exploited by an unauthenticated user. The j_username parameter seems to be vulnerable and a reverse shell could be obtained if a privileged user exports "User Attempts Audit Report" as CSV file. Note: The vendor disputes this vulnerability, claiming "This is not a valid vulnerability in our ADSSP product. We don't see this as a security issue at our side. |
| An issue was discovered in src/http/httpLib.c in EmbedThis Appweb Community Edition 8.2.1, allows attackers to cause a denial of service via the stream paramter to the parseUri function. |
| An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Unauthenticated API Endpoints. |
| An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. Hard-coded API Keys exist. |
| An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Hard-coded Web Application Administrator Passwords for the admin and nplus1user accounts. |
| An issue was discovered in CommScope Ruckus IoT Controller 1.7.1.0 and earlier. There are Hard-coded System Passwords that provide shell access. |