Mingsoft MCMS 5.2.8 was discovered to contain a SQL injection vulnerability in /mdiy/model/delete URI via models Lists.
Search vulnerabilities
Mapper v4.0.0 to v4.2.0 was discovered to contain a SQL injection vulnerability via the ids parameter at the selectByIds function.
In D-Link DAP1650 v1.04 firmware, the fileaccess.cgi program in the firmware has a buffer overflow vulnerability caused by strncpy.
In Tenda G3 US_G3V3.0br_V15.11.0.6(7663)_EN_TDE, there is a buffer overflow vulnerability caused by strcpy in function 0x869f4 in the httpd binary.
In Tenda G3 US_G3V3.0br_V15.11.0.6(7663)_EN_TDE, in httpd binary, the addDhcpRule function has a buffer overflow caused by sscanf.
In Tenda G3 US_G3V3.0br_V15.11.0.6(7663)_EN_TDE, the getsinglepppuser function has a buffer overflow caused by sscanf.
jizhicms v2.3.1 has SQL injection in the background.
Sinsiu Sinsiu Enterprise Website System v1.1.1.0 was discovered to contain a remote code execution (RCE) vulnerability via the component /upload/admin.php?/deal/.
Rengine v1.3.0 was discovered to contain a command injection vulnerability via the scan engine function.
Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain multiple hard-coded passcodes for root. Attackers are able to access the passcodes at /etc/srapi/config/system.conf and /usr/sbin/ssol-sshd.sh.
Seiko SkyBridge MB-A200 v01.00.04 and below was discovered to contain a command injection vulnerability via the Ping parameter at ping_exec.cgi.
Seiko SkyBridge MB-A100/A110 v4.2.0 and below implements a hard-coded passcode for the root account. Attackers are able to access the passcord via the file /etc/ciel.cfg.
Seiko SkyBridge MB-A100/A110 v4.2.0 and below was discovered to contain an arbitrary file upload vulnerability via the restore backup function. This vulnerability allows attackers to execute arbitrary code via a crafted html file.
Seiko SkyBridge MB-A100/A110 v4.2.0 and below was discovered to contain a command injection vulnerability via the ipAddress parameter at 07system08execute_ping_01.
Hytec Inter HWL-2511-SS v1.05 and below implements a SHA512crypt hash for the root account which can be easily cracked via a brute-force attack.
A command injection vulnerability in the CLI (Command Line Interface) implementation of Hytec Inter HWL-2511-SS v1.05 and below allows attackers to execute arbitrary commands with root privileges.
Hytec Inter HWL-2511-SS v1.05 and below was discovered to contain a command injection vulnerability via the component /www/cgi-bin/popen.cgi.
An issue in the component post_applogin.php of Super Flexible Software GmbH & Co. KG Syncovery 9 for Linux v9.47x and below allows attackers to escalate privileges via creating crafted session tokens.
D-Link Go-RT-AC750 GORTAC750_revA_v101b03 & GO-RT-AC750_revB_FWv200b02 is vulnerable to Buffer Overflow via authenticationcgi_main.
D-Link Go-RT-AC750 GORTAC750_revA_v101b03 & GO-RT-AC750_revB_FWv200b02 is vulnerable to command injection via /htdocs/upnpinc/gena.php.