Honeywell Experion PKS Safety Manager (SM and FSC) through 2022-05-06 has Insufficient Verification of Data Authenticity. According to FSCT-2022-0053, there is a Honeywell Experion PKS Safety Manager insufficient logic security controls issue. The affected components are characterized as: Honeywell FSC runtime (FSC-CPU, QPP), Honeywell Safety Builder. The potential impact is: Remote Code Execution, Denial of Service. The Honeywell Experion PKS Safety Manager family of safety controllers utilize the unauthenticated Safety Builder protocol (FSCT-2022-0051) for engineering purposes, including downloading projects and control logic to the controller. Control logic is downloaded to the controller on a block-by-block basis. The logic that is downloaded consists of FLD code compiled to native machine code for the CPU module (which applies to both the Safety Manager and FSC families). Since this logic does not seem to be cryptographically authenticated, it allows an attacker capable of triggering a logic download to execute arbitrary machine code on the controller's CPU module in the context of the runtime. While the researchers could not verify this in detail, the researchers believe that the microprocessor underpinning the FSC and Safety Manager CPU modules is incapable of offering memory protection or privilege separation capabilities which would give an attacker full control of the CPU module. There is no authentication on control logic downloaded to the controller. Memory protection and privilege separation capabilities for the runtime are possibly lacking. The researchers confirmed the issues in question on Safety Manager R145.1 and R152.2 but suspect the issue affects all FSC and SM controllers and associated Safety Builder versions regardless of software or firmware revision. An attacker who can communicate with a Safety Manager controller via the Safety Builder protocol can execute arbitrary code without restrictions on the CPU module, allowing for covert manipulation of control operations and implanting capabilities similar to the TRITON malware (MITRE ATT&CK software ID S1009). A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position.
Search vulnerabilities
FESTO: CECC-X-M1 and Servo Press Kit YJKP OS Command Injection vulnerability
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-refresh-request" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
FESTO: CECC-X-M1 and Servo Press Kit YJKP OS Command Injection vulnerability
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-acknerr-request" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
FESTO: CECC-X-M1 and Servo Press Kit YJKP OS Command Injection vulnerability
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-web-viewer-request-off" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
FESTO: CECC-X-M1 and Servo Press Kit YJKP OS Command Injection vulnerability
In Festo Controller CECC-X-M1 product family in multiple versions, the http-endpoint "cecc-x-web-viewer-request-on" POST request doesn’t check for port syntax. This can result in unauthorized execution of system commands with root privileges due to improper access control command injection.
Heap-based buffer overflow in sqbaselib.cpp in SQUIRREL 3.2 due to lack of a certain sq_reservestack call.
In Quest KACE Systems Management Appliance (SMA) through 12.0, a hash collision is possible during authentication. This may allow authentication with invalid credentials.
In the python-libnmap package through 0.7.2 for Python, remote command execution can occur (if used in a client application that does not validate arguments). NOTE: the vendor believes it would be unrealistic for an application to call NmapProcess with arguments taken from input data that arrived over an untrusted network, and thus the CVSS score corresponds to an unrealistic use case. None of the NmapProcess documentation implies that this is an expected use case
The Motorola ACE1000 RTU through 2022-05-02 uses ECB encryption unsafely. It can communicate with an XRT LAN-to-radio gateway by means of an embedded client. Credentials for accessing this gateway are stored after being encrypted with the Tiny Encryption Algorithm (TEA) in ECB mode using a hardcoded key. Similarly, the ACE1000 RTU can route MDLC traffic over Extended Command and Management Protocol (XCMP) and Network Layer (XNL) networks via the MDLC driver. Authentication to the XNL port is protected by TEA in ECB mode using a hardcoded key.
The Motorola MDLC protocol through 2022-05-02 mishandles message integrity. It supports three security modes: Plain, Legacy Encryption, and New Encryption. In Legacy Encryption mode, traffic is encrypted via the Tiny Encryption Algorithm (TEA) block-cipher in ECB mode. This mode of operation does not offer message integrity and offers reduced confidentiality above the block level, as demonstrated by an ECB Penguin attack against any block ciphers.
The Motorola ACE1000 RTU through 2022-05-02 ships with a hardcoded SSH private key and initialization scripts (such as /etc/init.d/sshd_service) only generate a new key if no private-key file exists. Thus, this hardcoded key is likely to be used by default.
The Motorola ACE1000 RTU through 2022-05-02 has default credentials. It exposes an SSH interface on port 22/TCP. This interface is used for remote maintenance and for SFTP file-transfer operations that are part of engineering software functionality. Access to this interface is controlled by 5 preconfigured accounts (root, abuilder, acelogin, cappl, ace), all of which come with default credentials. Although the ACE1000 documentation mentions the root, abuilder and acelogin accounts and instructs users to change the default credentials, the cappl and ace accounts remain undocumented and thus are unlikely to have their credentials changed.
The Emerson ROC and FloBoss RTU product lines through 2022-05-02 perform insecure filesystem operations. They utilize the ROC protocol (4000/TCP, 5000/TCP) for communications between a master terminal and RTUs. Opcode 203 of this protocol allows a master terminal to transfer files to and from the flash filesystem and carrying out arbitrary file and directory read, write, and delete operations.
A CWE-798: Use of Hard-coded Credentials vulnerability exists that could allow arbitrary code to be executed when root level access is obtained. Affected Products: Wiser Smart, EER21000 & EER21001 (V4.5 and prior)
rubygem-rack: crafted requests can cause shell escape sequences
A sequence injection vulnerability exists in Rack <2.0.9.1, <2.1.4.1 and <2.2.3.1 which could allow is a possible shell escape in the Lint and CommonLogger components of Rack.
Concrete 8.5.7 and below as well as Concrete 9.0 through 9.0.2 allow traversal in /index.php/ccm/system/file/upload which could result in an Arbitrary File Delete exploit. This was remediated by sanitizing /index.php/ccm/system/file/upload to ensure Concrete doesn’t allow traversal and by changing isFullChunkFilePresent to have an early false return when input doesn't match expectations.Concrete CMS Security team ranked this 5.8 with CVSS v3.1 vector AV:N/AC:H/PR:H/UI:N/S:C/C:N/I:N/A:H. Credit to Siebene for reporting.
Electronic mall system 1.0_build20200203 is affected vulnerable to SQL Injection.
In Belkin N300 Firmware 1.00.08, the script located at /setting_hidden.asp, which is accessible before and after configuring the device, exhibits multiple remote command injection vulnerabilities. The following parameters in the [form name] form; [list vulnerable parameters], are not properly sanitized after being submitted to the web interface in a POST request. With specially crafted parameters, it is possible to inject a an OS command which will be executed with root privileges, as the web interface, and all processes on the device, run as root.
EllieGrid Android Application version 3.4.1 is vulnerable to Code Injection. The application appears to evaluate user input as code (remote).
ftcms <=2.1 was discovered to be vulnerable to code execution attacks .