Online Sports Complex Booking System 1.0 is vulnerable to SQL Injection via \scbs\classes\Master.php?f=delete.
Search vulnerabilities
Online Sports Complex Booking System 1.0 is vulnerable to SQL Injection via /scbs/admin/?page=user/manage_user&id=.
Online Sports Complex Booking System 1.0 is vulnerable to SQL Injection via \scbs\classes\Master.php?f=delete_facility.
Online Sports Complex Booking System 1.0 is vulnerable to SQL Injection via \scbs\classes\Master.php?f=delete_category.
Simple Client Management System 1.0 is vulnerable to SQL Injection via /cms/admin/?page=client/view_client&id=.
Simple Client Management System 1.0 is vulnerable to SQL Injection via /cms/admin/?page=invoice/view_invoice&id=.
Simple Client Management System 1.0 is vulnerable to SQL Injection via /cms/admin/maintenance/manage_service.php?id=.
Simple Client Management System 1.0 is vulnerable to SQL Injection via /cms/classes/Users.php?f=delete.
Simple Client Management System 1.0 is vulnerable to SQL Injection via /cms/admin/?page=user/manage_user&id=.
Simple Client Management System 1.0 is vulnerable to SQL Injection via /cms/classes/Master.php?f=delete_designation.
JTEKT TOYOPUC PLCs through 2022-04-29 do not ensure data integrity. They utilize the unauthenticated CMPLink/TCP protocol for engineering purposes, including downloading projects and control logic to the PLC. Control logic is downloaded to the PLC on a block-by-block basis with a given memory address and a blob of machine code. The logic that is downloaded to the PLC is not cryptographically authenticated, allowing an attacker to execute arbitrary machine code on the PLC's CPU module in the context of the runtime. In the case of the PC10G-CPU, and likely for other CPU modules of the TOYOPUC family, a processor without MPU or MMU is used and this no memory protection or privilege-separation capabilities are available, giving an attacker full control over the CPU.
The Bently Nevada 3700 series of condition monitoring equipment through 2022-04-29 has a maintenance interface on port 4001/TCP with undocumented, hardcoded credentials. An attacker capable of connecting to this interface can thus trivially take over its functionality.
Bently Nevada condition monitoring equipment through 2022-04-29 mishandles authentication. It utilizes the TDI command and data protocols (60005/TCP, 60007/TCP) for communications between the monitoring controller and System 1 and/or Bently Nevada Monitor Configuration (BNMC) software. These protocols provide configuration management and historical data related functionality. Neither protocol has any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality.
JTEKT TOYOPUC PLCs through 2022-04-29 mishandle authentication. They utilize the CMPLink/TCP protocol (configurable on ports 1024-65534 on either TCP or UDP) for a wide variety of engineering purposes such as starting and stopping the PLC, downloading and uploading projects, and changing configuration settings. This protocol does not have any authentication features, allowing any attacker capable of communicating with the port in question to invoke (a subset of) desired functionality.
The admin API module in the QuizGame extension for MediaWiki through 1.37.2 (before 665e33a68f6fa1167df99c0aa18ed0157cdf9f66) omits a check for the quizadmin user.
The SemanticDrilldown extension for MediaWiki through 1.37.2 (before e688bdba6434591b5dff689a45e4d53459954773) allows SQL injection with certain '-' and '_' constraints.
Remote Code Execution in all versions of various RAD-ISM-900-EN-* devices by PHOENIX CONTACT
On various RAD-ISM-900-EN-* devices by PHOENIX CONTACT an admin user could use the configuration file uploader in the WebUI to execute arbitrary code with root privileges on the OS due to an improper validation of an integrity check value in all versions of the firmware.
Remote Code Execution in all versions of various RAD-ISM-900-EN-* devices by PHOENIX CONTACT
On various RAD-ISM-900-EN-* devices by PHOENIX CONTACT an admin user could use the traceroute utility integrated in the WebUI to execute arbitrary code with root privileges on the OS due to an improper input validation in all versions of the firmware.
A vulnerability has been identified in Biograph Horizon PET/CT Systems (All VJ30 versions < VJ30C-UD01), MAGNETOM Family (NUMARIS X: VA12M, VA12S, VA10B, VA20A, VA30A, VA31A), MAMMOMAT Revelation (All VC20 versions < VC20D), NAEOTOM Alpha (All VA40 versions < VA40 SP2), SOMATOM X.cite (All versions < VA30 SP5 or VA40 SP2), SOMATOM X.creed (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.All (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Now (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Open Pro (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Sim (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Top (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Up (All versions < VA30 SP5 or VA40 SP2), Symbia E/S (All VB22 versions < VB22A-UD03), Symbia Evo (All VB22 versions < VB22A-UD03), Symbia Intevo (All VB22 versions < VB22A-UD03), Symbia T (All VB22 versions < VB22A-UD03), Symbia.net (All VB22 versions < VB22A-UD03), syngo.via VB10 (All versions), syngo.via VB20 (All versions), syngo.via VB30 (All versions), syngo.via VB40 (All versions < VB40B HF06), syngo.via VB50 (All versions), syngo.via VB60 (All versions < VB60B HF02). The application deserialises untrusted data without sufficient validations that could result in an arbitrary deserialization. This could allow an unauthenticated attacker to execute code in the affected system if ports 32912/tcp or 32914/tcp are reachable.
component/common/network/dhcp/dhcps.c in ambiot amb1_sdk (aka SDK for Ameba1) before 2022-03-11 mishandles data structures for DHCP packet data.