| Django 2.1 before 2.1.15 and 2.2 before 2.2.8 allows unintended model editing. A Django model admin displaying inline related models, where the user has view-only permissions to a parent model but edit permissions to the inline model, would be presented with an editing UI, allowing POST requests, for updating the inline model. Directly editing the view-only parent model was not possible, but the parent model's save() method was called, triggering potential side effects, and causing pre and post-save signal handlers to be invoked. (To resolve this, the Django admin is adjusted to require edit permissions on the parent model in order for inline models to be editable.) |
| /usr/lib/lua/luci/controller/admin/autoupgrade.lua on PHICOMM K2(PSG1218) V22.5.9.163 devices allows remote authenticated users to execute any command via shell metacharacters in the cgi-bin/luci autoUpTime parameter. |
| An escalation of privilege vulnerability in Nahimic APO Software Component Driver 1.4.2, 1.5.0, 1.5.1, 1.6.1 and 1.6.2 allows an attacker to execute code with SYSTEM privileges. |
| main/resources/mapper/NewBeeMallGoodsMapper.xml in newbee-mall (aka New Bee) before 2019-10-23 allows search?goodsCategoryId=&keyword= SQL Injection. |
| The wpForo plugin 1.6.5 for WordPress allows XSS involving the wpf-dw-td-value class of dashboard.php. |
| The wpForo plugin 1.6.5 for WordPress allows XSS via the wp-admin/admin.php?page=wpforo-phrases langid parameter. |
| The wpForo plugin 1.6.5 for WordPress allows XSS via the wp-admin/admin.php?page=wpforo-phrases s parameter. |
| The wpForo plugin 1.6.5 for WordPress allows wp-admin/admin.php?page=wpforo-usergroups CSRF. |
| An authentication weakness in the SNMP service in B&R Automation Runtime versions 2.96, 3.00, 3.01, 3.06 to 3.10, 4.00 to 4.63, 4.72 and above allows unauthenticated users to modify the configuration of B&R products via SNMP. |
| The Configuration pages in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway for user profiles and services transfer the password in plaintext (although hidden when displayed). |
| Improper implementation of Access Control in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows an unauthorized user to access data marked as restricted, such as viewing or editing user profiles and application settings. |
| The backup function in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway saves the current settings and configuration of the application, including credentials of existing user accounts and other configuration's credentials in plaintext. |
| The web server in ABB Telephone Gateway TG/S 3.2 and Busch-Jaeger 6186/11 Telefon-Gateway allows access to different endpoints of the application without authenticating by accessing a specific uniform resource locator (URL) , violating the access-control (ACL) rules. This issue allows obtaining sensitive information that may aid in further attacks and privilege escalation. |
| A directory traversal vulnerability in SharpZipLib used in the upgrade service in B&R Automation Studio versions 4.0.x, 4.1.x and 4.2.x allow unauthenticated users to write to certain local directories. The vulnerability is also known as zip slip. |
| A missing secure communication definition and an incomplete TLS validation in the upgrade service in B&R Automation Studio versions 4.0.x, 4.1.x, 4.2.x, < 4.3.11SP, < 4.4.9SP, < 4.5.5SP, < 4.6.4 and < 4.7.2 enable unauthenticated users to perform MITM attacks via the B&R upgrade server. |
| A privilege escalation vulnerability in the upgrade service in B&R Automation Studio versions 4.0.x, 4.1.x, 4.2.x, < 4.3.11SP, < 4.4.9SP, < 4.5.4SP, <. 4.6.3SP, < 4.7.2 and < 4.8.1 allow authenticated users to delete arbitrary files via an exposed interface. |
| ABB eSOMS versions 4.0 to 6.0.3 accept connections using medium strength ciphers. If a connection is enabled using such a cipher, an attacker might be able to eavesdrop and/or intercept the connection. |
| The Redis data structure component used in ABB eSOMS versions 6.0 to 6.0.2 stores credentials in clear text. If an attacker has file system access, this can potentially compromise the credentials' confidentiality. |
| Lack of adequate input/output validation for ABB eSOMS versions 4.0 to 6.0.2 might allow an attacker to attack such as stored cross-site scripting by storing malicious content in the database. |
| Lack of input checks for SQL queries in ABB eSOMS versions 3.9 to 6.0.3 might allow an attacker SQL injection attacks against the backend database. |