Search Results (366296 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2021-40375 1 Apperta 1 Openeyes 2024-11-21 6.5 Medium
Apperta Foundation OpenEyes 3.5.1 allows remote attackers to view the sensitive information of patients without having the intended level of privilege. Despite OpenEyes returning a Forbidden error message, the contents of a patient's profile are still returned in the server response. This response can be read in an intercepting proxy or by viewing the page source. Sensitive information returned in responses includes patient PII and medication records or history.
CVE-2021-40374 1 Apperta 1 Openeye 2024-11-21 5.4 Medium
A stored cross-site scripting (XSS) vulnerability was identified in Apperta Foundation OpenEyes 3.5.1. Updating a patient's details allows remote attackers to inject arbitrary web script or HTML via the Address1 parameter. This JavaScript then executes when the patient profile is loaded, which could be used in a XSS attack.
CVE-2021-40373 1 Playsms 1 Playsms 2024-11-21 9.8 Critical
playSMS before 1.4.5 allows Arbitrary Code Execution by entering PHP code at the #tabs-information-page of core_main_config, and then executing that code via the index.php?app=main&inc=core_welcome URI.
CVE-2021-40371 1 Gridprosoftware 1 Request Management 2024-11-21 9.8 Critical
Gridpro Request Management for Windows Azure Pack before 2.0.7912 allows Directory Traversal for remote code execution, as demonstrated by ..\\ in a scriptName JSON value to ServiceManagerTenant/GetVisibilityMap.
CVE-2021-40369 1 Apache 1 Jspwiki 2024-11-21 6.1 Medium
A carefully crafted plugin link invocation could trigger an XSS vulnerability on Apache JSPWiki, related to the Denounce plugin, which could allow the attacker to execute javascript in the victim's browser and get some sensitive information about the victim. Apache JSPWiki users should upgrade to 2.11.0 or later.
CVE-2021-40366 1 Siemens 2 Climatix Pol909, Climatix Pol909 Firmware 2024-11-21 7.4 High
A vulnerability has been identified in Climatix POL909 (AWB module) (All versions < V11.42), Climatix POL909 (AWM module) (All versions < V11.34). The web server of affected devices transmits data without TLS encryption. This could allow an unauthenticated remote attacker in a man-in-the-middle position to read sensitive data, such as administrator credentials, or modify data in transit.
CVE-2021-40364 1 Siemens 2 Simatic Pcs 7, Simatic Wincc 2024-11-21 5.5 Medium
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). The affected systems store sensitive information in log files. An attacker with access to the log files could publicly expose the information or reuse it to develop further attacks on the system.
CVE-2021-40363 1 Siemens 2 Simatic Pcs 7, Simatic Wincc 2024-11-21 7.8 High
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V17 (All versions <= V17 Update 4), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The affected component stores the credentials of a local system account in a potentially publicly accessible project file using an outdated cipher algorithm. An attacker may use this to brute force the credentials and take over the system.
CVE-2021-40360 1 Siemens 2 Simatic Pcs 7, Simatic Wincc 2024-11-21 8.8 High
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 6). The password hash of a local user account in the remote server could be granted via public API to a user on the affected system. An authenticated attacker could brute force the password hash and use it to login to the server.
CVE-2021-40359 1 Siemens 5 Simatic Batch, Simatic Net Pc, Simatic Route Control and 2 more 2024-11-21 7.7 High
A vulnerability has been identified in OpenPCS 7 V8.2 (All versions), OpenPCS 7 V9.0 (All versions < V9.0 Upd4), OpenPCS 7 V9.1 (All versions), SIMATIC BATCH V8.2 (All versions), SIMATIC BATCH V9.0 (All versions), SIMATIC BATCH V9.1 (All versions), SIMATIC NET PC Software V14 (All versions), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Update 6), SIMATIC NET PC Software V17 (All versions < V17 SP1), SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC Route Control V8.2 (All versions), SIMATIC Route Control V9.0 (All versions), SIMATIC Route Control V9.1 (All versions), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). When downloading files, the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read unexpected critical files.
CVE-2021-40358 1 Siemens 2 Simatic Pcs 7, Simatic Wincc 2024-11-21 9.9 Critical
A vulnerability has been identified in SIMATIC PCS 7 V8.2 (All versions), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP3 UC04), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP1), SIMATIC WinCC V15 and earlier (All versions < V15 SP1 Update 7), SIMATIC WinCC V16 (All versions < V16 Update 5), SIMATIC WinCC V17 (All versions < V17 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 19), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 5). Legitimate file operations on the web server of the affected systems do not properly neutralize special elements within the pathname. An attacker could then cause the pathname to resolve to a location outside of the restricted directory on the server and read, write or delete unexpected critical files.
CVE-2021-40357 1 Siemens 1 Teamcenter Active Workspace 2024-11-21 4.9 Medium
A vulnerability has been identified in Teamcenter Active Workspace V4.3 (All versions < V4.3.10), Teamcenter Active Workspace V5.0 (All versions < V5.0.8), Teamcenter Active Workspace V5.1 (All versions < V5.1.5), Teamcenter Active Workspace V5.2 (All versions < V5.2.1). A path traversal vulnerability in the application could allow an attacker to bypass certain restrictions such as direct access to other services within the host.
CVE-2021-40356 1 Siemens 1 Teamcenter Visualization 2024-11-21 7.5 High
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.8), Teamcenter V13.0 (All versions < V13.0.0.7), Teamcenter V13.1 (All versions < V13.1.0.5), Teamcenter V13.2 (All versions < 13.2.0.2). The application contains a XML External Entity Injection (XXE) vulnerability. This could allow an attacker to view files on the application server filesystem.
CVE-2021-40355 1 Siemens 1 Teamcenter Visualization 2024-11-21 8.8 High
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.8), Teamcenter V13.0 (All versions < V13.0.0.7), Teamcenter V13.1 (All versions < V13.1.0.5), Teamcenter V13.2 (All versions < 13.2.0.2). The affected application contains Insecure Direct Object Reference (IDOR) vulnerability that allows an attacker to use user-supplied input to access objects directly.
CVE-2021-40354 1 Siemens 1 Teamcenter Visualization 2024-11-21 7.1 High
A vulnerability has been identified in Teamcenter V12.4 (All versions < V12.4.0.8), Teamcenter V13.0 (All versions < V13.0.0.7), Teamcenter V13.1 (All versions < V13.1.0.5), Teamcenter V13.2 (All versions < 13.2.0.2). The "surrogate" functionality on the user profile of the application does not perform sufficient access control that could lead to an account takeover. Any profile on the application can perform this attack and access any other user assigned tasks via the "inbox/surrogate tasks".
CVE-2021-40353 1 Os4ed 1 Opensis 2024-11-21 9.8 Critical
A SQL injection vulnerability exists in version 8.0 of openSIS when MySQL or MariaDB is used as the application database. An attacker can then issue the SQL command through the index.php USERNAME parameter. NOTE: this issue may exist because of an incomplete fix for CVE-2020-6637.
CVE-2021-40352 1 Open-emr 1 Openemr 2024-11-21 6.5 Medium
OpenEMR 6.0.0 has a pnotes_print.php?noteid= Insecure Direct Object Reference vulnerability via which an attacker can read the messages of all users.
CVE-2021-40350 1 Christiedigital 2 Dwu850-gs, Dwu850-gs Firmware 2024-11-21 9.8 Critical
webctrl.cgi.elf on Christie Digital DWU850-GS V06.46 devices allows attackers to perform any desired action via a crafted query containing an unspecified Cookie header. Authentication bypass can be achieved by including an administrative cookie that the device does not validate.
CVE-2021-40349 1 Speed Test Project 1 Speed Test 2024-11-21 5.3 Medium
e7d Speed Test (aka speedtest) 0.5.3 allows a path-traversal attack that results in information disclosure via the "GET /.." substring.
CVE-2021-40348 2 Spacewalk Project, Uyuni-project 2 Spacewalk, Uyuni 2024-11-21 8.8 High
Spacewalk 2.10, and derivatives such as Uyuni 2021.08, allows code injection. rhn-config-satellite.pl doesn't sanitize the configuration filename used to append Spacewalk-specific key-value pair. The script is intended to be run by the tomcat user account with Sudo, according to the installation setup. This can lead to the ability of an attacker to use --option to append arbitrary code to a root-owned file that eventually will be executed by the system. This is fixed in Uyuni spacewalk-admin 4.3.2-1.