Search Results (329335 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2019-13571 1 Vsourz 1 Advanced Cf7 Db 2024-11-21 9.8 Critical
A SQL injection vulnerability exists in the Vsourz Digital Advanced CF7 DB plugin through 1.6.1 for WordPress. Successful exploitation of this vulnerability would allow a remote attacker to execute arbitrary SQL commands on the affected system.
CVE-2019-13570 1 Ajdg 1 Adrotate 2024-11-21 N/A
The AJdG AdRotate plugin before 5.3 for WordPress allows SQL Injection.
CVE-2019-13569 1 Icegram 1 Email Subscribers \& Newsletters 2024-11-21 N/A
A SQL injection vulnerability exists in the Icegram Email Subscribers & Newsletters plugin through 4.1.7 for WordPress. Successful exploitation of this vulnerability would allow a remote attacker to execute arbitrary SQL commands on the affected system.
CVE-2019-13568 1 Cimg 1 Cimg 2024-11-21 N/A
CImg through 2.6.7 has a heap-based buffer overflow in _load_bmp in CImg.h because of erroneous memory allocation for a malformed BMP image.
CVE-2019-13567 1 Zoom 1 Zoom 2024-11-21 8.8 High
The Zoom Client before 4.4.53932.0709 on macOS allows remote code execution, a different vulnerability than CVE-2019-13450. If the ZoomOpener daemon (aka the hidden web server) is running, but the Zoom Client is not installed or can't be opened, an attacker can remotely execute code with a maliciously crafted launch URL. NOTE: ZoomOpener is removed by the Apple Malware Removal Tool (MRT) if this tool is enabled and has the 2019-07-10 MRTConfigData.
CVE-2019-13566 1 Ros 1 Ros-comm 2024-11-21 9.8 Critical
An issue was discovered in the ROS communications-related packages (aka ros_comm or ros-melodic-ros-comm) through 1.14.3. A buffer overflow allows attackers to cause a denial of service and possibly execute arbitrary code via an IP address with a long hostname.
CVE-2019-13565 7 Apple, Canonical, Debian and 4 more 9 Mac Os X, Ubuntu Linux, Debian Linux and 6 more 2024-11-21 7.5 High
An issue was discovered in OpenLDAP 2.x before 2.4.48. When using SASL authentication and session encryption, and relying on the SASL security layers in slapd access controls, it is possible to obtain access that would otherwise be denied via a simple bind for any identity covered in those ACLs. After the first SASL bind is completed, the sasl_ssf value is retained for all new non-SASL connections. Depending on the ACL configuration, this can affect different types of operations (searches, modifications, etc.). In other words, a successful authorization step completed by one user affects the authorization requirement for a different user.
CVE-2019-13564 1 Pingidentity 1 Agentless Integration Kit 2024-11-21 6.1 Medium
XSS exists in Ping Identity Agentless Integration Kit before 1.5.
CVE-2019-13563 1 Dlink 2 Dir-655, Dir-655 Firmware 2024-11-21 8.8 High
D-Link DIR-655 C devices before 3.02B05 BETA03 allow CSRF for the entire management console.
CVE-2019-13562 1 Dlink 2 Dir-655, Dir-655 Firmware 2024-11-21 N/A
D-Link DIR-655 C devices before 3.02B05 BETA03 allow XSS, as demonstrated by the /www/ping_response.cgi ping_ipaddr parameter, the /www/ping6_response.cgi ping6_ipaddr parameter, and the /www/apply_sec.cgi html_response_return_page parameter.
CVE-2019-13561 1 Dlink 2 Dir-655, Dir-655 Firmware 2024-11-21 N/A
D-Link DIR-655 C devices before 3.02B05 BETA03 allow remote attackers to execute arbitrary commands via shell metacharacters in the online_firmware_check.cgi check_fw_url parameter.
CVE-2019-13560 1 Dlink 2 Dir-655, Dir-655 Firmware 2024-11-21 9.8 Critical
D-Link DIR-655 C devices before 3.02B05 BETA03 allow remote attackers to force a blank password via the apply_sec.cgi setup_wizard parameter.
CVE-2019-13559 1 Ge 1 Mark Vie Controll System 2024-11-21 7.8 High
GE Mark VIe Controller is shipped with pre-configured hard-coded credentials that may allow root-user access to the controller. A limited application of the affected product may ship without setup and configuration instructions immediately available to the end user. The bulk of controllers go into applications requiring the GE commissioning engineer to change default configurations during the installation process. GE recommends that users reset controller passwords during installation in the operating environment.
CVE-2019-13558 1 Advantech 1 Webaccess 2024-11-21 9.8 Critical
In WebAccess versions 8.4.1 and prior, an exploit executed over the network may cause improper control of generation of code, which may allow remote code execution, data exfiltration, or cause a system crash.
CVE-2019-13557 1 Philips 2 Tasy Emr, Tasy Webportal 2024-11-21 5.3 Medium
In Tasy EMR, Tasy WebPortal Versions 3.02.1757 and prior, there is an information exposure vulnerability which may allow a remote attacker to access system and configuration information.
CVE-2019-13556 1 Advantech 1 Webaccess 2024-11-21 8.8 High
In WebAccess versions 8.4.1 and prior, multiple stack-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution.
CVE-2019-13555 1 Mitsubishielectric 20 L02\/06\/26cpu, L02\/06\/26cpu-cm, L02\/06\/26cpu-cm Firmware and 17 more 2024-11-21 5.9 Medium
In Mitsubishi Electric MELSEC-Q Series Q03/04/06/13/26UDVCPU: serial number 21081 and prior, Q04/06/13/26UDPVCPU: serial number 21081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 21081 and prior, MELSEC-L Series L02/06/26CPU, L26CPU-BT: serial number 21101 and prior, L02/06/26CPU-P, L26CPU-PBT: serial number 21101 and prior, and L02/06/26CPU-CM, L26CPU-BT-CM: serial number 21101 and prior, a remote attacker can cause the FTP service to enter a denial-of-service condition dependent on the timing at which a remote attacker connects to the FTP server on the above CPU modules.
CVE-2019-13554 1 Ge 1 Mark Vie Control System 2024-11-21 8.8 High
GE Mark VIe Controller has an unsecured Telnet protocol that may allow a user to create an authenticated session using generic default credentials. GE recommends that users disable the Telnet service.
CVE-2019-13553 2 Carel, Rittal 2 Pcoweb Firmware, Chiller Sk 3232 2024-11-21 9.8 Critical
Rittal Chiller SK 3232-Series web interface as built upon Carel pCOWeb firmware A1.5.3 – B1.2.4. The authentication mechanism on affected systems is configured using hard-coded credentials. These credentials could allow attackers to influence the primary operations of the affected systems, namely turning the cooling unit on and off and setting the temperature set point.
CVE-2019-13552 1 Advantech 1 Webaccess 2024-11-21 8.8 High
In WebAccess versions 8.4.1 and prior, multiple command injection vulnerabilities are caused by a lack of proper validation of user-supplied data and may allow arbitrary file deletion and remote code execution.