| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| SaltOS 3.1 r8126 allows action=login&querystring=&user=[SQL] SQL Injection. |
| K-iwi Framework 1775 has SQL Injection via the admin/user/group/update user_group_id parameter or the admin/user/user/update user_id parameter. |
| An Incorrect Access Control vulnerability has been identified in Citrix XenMobile Server 10.8.0 before Rolling Patch 6 and 10.9.0 before Rolling Patch 3. An attacker can impersonate and take actions on behalf of any Mobile Application Management (MAM) enrolled device. |
| A privilege escalation issue was discovered in VyOS 1.1.8. The default configuration also allows operator users to execute the pppd binary with elevated (sudo) permissions. Certain input parameters are not properly validated. A malicious operator user can run the binary with elevated permissions and leverage its improper input validation condition to spawn an attacker-controlled shell with root privileges. |
| DENX U-Boot through 2018.09-rc1 has a remotely exploitable buffer overflow via a malicious TFTP server because TFTP traffic is mishandled. Also, local exploitation can occur via a crafted kernel image. |
| An issue was discovered in DuomiCMS 3.0. SQL injection exists in the ajax.php file, as demonstrated by the uid parameter. |
| dirary0.js on D-Link DIR-140L, DIR-640L devices allows remote unauthenticated attackers to discover admin credentials. |
| atbox.htm on D-Link DSL-2770L devices allows remote unauthenticated attackers to discover admin credentials. |
| LayerBB 1.1.1 and 1.1.3 has SQL Injection via the search.php search_query parameter. |
| qemu_deliver_packet_iov in net/net.c in Qemu accepts packet sizes greater than INT_MAX, which allows attackers to cause a denial of service or possibly have unspecified other impact. |
| An Improper Privilege Management in crowbar of SUSE OpenStack Cloud 7, SUSE OpenStack Cloud 8, SUSE OpenStack Cloud 9, SUSE OpenStack Cloud Crowbar 8, SUSE OpenStack Cloud Crowbar 9 allows root users on any crowbar managed node to cause become root on any other node. This issue affects: SUSE OpenStack Cloud 7 crowbar-core versions prior to 4.0+git.1578392992.fabfd186c-9.63.1, crowbar-. SUSE OpenStack Cloud 8 ardana-cinder versions prior to 8.0+git.1579279939.ee7da88-3.39.3, ardana-. SUSE OpenStack Cloud 9 ardana-ansible versions prior to 9.0+git.1581611758.f694f7d-3.16.1, ardana-. SUSE OpenStack Cloud Crowbar 8 crowbar-core versions prior to 5.0+git.1582968668.1a55c77c5-3.35.4, crowbar-. SUSE OpenStack Cloud Crowbar 9 crowbar-core versions prior to 6.0+git.1582892022.cbd70e833-3.19.3, crowbar-. |
| JUUKO K-800 (Firmware versions prior to numbers ending ...9A, ...9B, ...9C, etc.) is vulnerable to a replay attack and command forgery, which could allow attackers to replay commands, control the device, view commands, or cause the device to stop running. |
| A stack-based buffer overflow vulnerability has been identified in Teledyne DALSA Sherlock Version 7.2.7.4 and prior, which may allow remote code execution. |
| InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. A remote attacker could send a carefully crafted packet to exploit a stack-based buffer overflow vulnerability during tag, alarm, or event related actions such as read and write, with potential for code to be executed. If InduSoft Web Studio remote communication security was not enabled, or a password was left blank, a remote user could send a carefully crafted packet to invoke an arbitrary process, with potential for code to be executed. The code would be executed under the privileges of the InduSoft Web Studio or InTouch Edge HMI runtime and could lead to a compromise of the InduSoft Web Studio or InTouch Edge HMI server machine. |
| InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. This vulnerability could allow an unauthenticated user to remotely execute code with the same privileges as that of the InduSoft Web Studio or InTouch Edge HMI (formerly InTouch Machine Edition) runtime. |
| SAGA1-L8B with any firmware versions prior to A0.10 are vulnerable to a replay attack and command forgery. |
| NUUO CMS all versions 3.1 and prior, The application uses insecure and outdated software components for functionality, which could allow arbitrary code execution. |
| An issue was discovered on certain ABUS TVIP cameras. The CGI scripts allow remote attackers to execute code via system() as root. There are several injection points in various scripts. |
| Buffer Overflow vulnerability in certain ABUS TVIP cameras allows attackers to gain control of the program via crafted string sent to sprintf() function. |
| SQL injection exists in Scriptzee Hotel Booking Engine 1.0 via the hotels h_room_type parameter. |