AUVESY Versiondog
There are multiple API function codes that permit data writing to any file, which may allow an attacker to modify existing files or create new files.
There are multiple API function codes that permit data writing to any file, which may allow an attacker to modify existing files or create new files.
InHand Networks IR615 Router's Versions 2.3.0.r4724 and 2.3.0.r4870 are vulnerable to an attacker using a ping tool to inject commands into the device. This may allow the attacker to remotely run commands on behalf of the device.
Many of the services used by the affected product do not specify full paths for the DLLs they are loading. An attacker can exploit the uncontrolled search path by implanting their own DLL near the affected product’s binaries, thus hijacking the loaded DLL.
InHand Networks IR615 Router's Versions 2.3.0.r4724 and 2.3.0.r4870 does not enforce an efficient password policy. This may allow an attacker with obtained user credentials to enumerate passwords and impersonate other application users and perform operations on their behalf.
A path traversal vulnerability in the Moxa MXview Network Management software Versions 3.x to 3.2.2 may allow an attacker to create or overwrite critical files used to execute code, such as programs or libraries.
The server permits communication without any authentication procedure, allowing the attacker to initiate a session with the server without providing any form of authentication.
A use of hard-coded password vulnerability in the Moxa MXview Network Management software Versions 3.x to 3.2.2 may allow an attacker to gain access through accounts using default passwords
A path traversal vulnerability in the Moxa MXview Network Management software Versions 3.x to 3.2.2 may allow an attacker to create or overwrite critical files used to execute code, such as programs or libraries.
Some API functions allow interaction with the registry, which includes reading values as well as data modification.
The affected controllers do not properly sanitize the input containing code syntax. As a result, an attacker could craft code to alter the intended controller flow of the software.
Some API functions permit by-design writing or copying data into a given buffer. Since the client controls these parameters, an attacker could rewrite the memory in any location of the affected product.
FATEK Automation Communication Server Versions 1.13 and prior lacks proper validation of user-supplied data, which could result in a stack-based buffer overflow condition and allow an attacker to remotely execute code.
Properly formatted POST requests to multiple resources on the HTTP and HTTPS web servers of the Digi PortServer TS 16 Rack device do not require authentication or authentication tokens. This vulnerability could allow an attacker to enable the SNMP service and manipulate the community strings to achieve further control in.
A stack-based buffer overflow vulnerability in Advantech WebAccess Versions 9.02 and prior caused by a lack of proper validation of the length of user-supplied data may allow remote code execution.
A Blind SQL injection vulnerability exists in the /DataHandler/HandlerAlarmGroup.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter agid before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICE\MSSQLSERVER.
A Blind SQL injection vulnerability exists in the /DataHandler/AM/AM_Handler.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter type before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICE\MSSQLSERVER.
A Blind SQL injection vulnerability exists in the /DataHandler/HandlerEnergyType.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter egyid before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICE\MSSQLSERVER.
Advantech WebAccess versions 9.02 and prior are vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute code.
Serverless Offline 8.0.0 returns a 403 HTTP status code for a route that has a trailing / character, which might cause a developer to implement incorrect access control, because the actual behavior within the Amazon AWS environment is a 200 HTTP status code (i.e., possibly greater than expected permissions).
Network Attached Storage on LG N1T1*** 10124 devices allows an unauthenticated attacker to gain root access via OS command injection in the en/ajp/plugins/access.ssh/checkInstall.php destServer parameter.