| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| In Materialize through 1.0.0, XSS is possible via the Autocomplete feature. |
| In Materialize through 1.0.0, XSS is possible via the Tooltip feature. |
| An issue was discovered in GitLab Enterprise Edition before 11.7.11, 11.8.x before 11.8.7, and 11.9.x before 11.9.7. It allows Information Disclosure. |
| The D-Link DCS series of Wi-Fi cameras contains a stack-based buffer overflow in alphapd, the camera's web server. The overflow allows a remotely authenticated attacker to execute arbitrary code by providing a long string in the WEPEncryption parameter when requesting wireless.htm. Vulnerable devices include DCS-5009L (1.08.11 and below), DCS-5010L (1.14.09 and below), DCS-5020L (1.15.12 and below), DCS-5025L (1.03.07 and below), DCS-5030L (1.04.10 and below), DCS-930L (2.16.01 and below), DCS-931L (1.14.11 and below), DCS-932L (2.17.01 and below), DCS-933L (1.14.11 and below), and DCS-934L (1.05.04 and below). |
| An issue was discovered on Phoenix Contact AXC F 2152 (No.2404267) before 2019.0 LTS and AXC F 2152 STARTERKIT (No.1046568) before 2019.0 LTS devices. Unlimited physical access to the PLC may lead to a manipulation of SD cards data. SD card manipulation may lead to an authentication bypass opportunity. |
| An issue was discovered on Phoenix Contact AXC F 2152 (No.2404267) before 2019.0 LTS and AXC F 2152 STARTERKIT (No.1046568) before 2019.0 LTS devices. Protocol Fuzzing on PC WORX Engineer by a man in the middle attacker stops the PLC service. The device must be rebooted, or the PLC service must be restarted manually via a Linux shell. |
| Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, allow multiple vulnerabilities to be exploited when a valid user opens a specially crafted, malicious input file that can reference memory after it has been freed. |
| ABB CP651 HMI products revision BSP UN30 v1.76 and prior implement hidden administrative accounts that are used during the provisioning phase of the HMI interface. |
| Processing a specially crafted project file in LAquis SCADA 4.3.1.71 may trigger an out-of-bounds read, which may allow an attacker to obtain sensitive information. The attacker must have local access to the system. A CVSS v3 base score of 2.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N). |
| In WebAccess/SCADA Versions 8.3.5 and prior, multiple untrusted pointer dereference vulnerabilities may allow a remote attacker to execute arbitrary code. |
| Delta Electronics CNCSoft ScreenEditor, Versions 1.00.89 and prior. Multiple out-of-bounds read vulnerabilities may cause information disclosure due to lacking user input validation for processing project files. |
| In WebAccess/SCADA, Versions 8.3.5 and prior, multiple stack-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution. |
| Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, uses a hard-coded password to encrypt protected files in transit and at rest, which may allow an attacker to access configuration files. |
| In WebAccess/SCADA Versions 8.3.5 and prior, multiple heap-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution. Note: A different vulnerability than CVE-2019-10991. |
| In Philips HDI 4000 Ultrasound Systems, all versions running on old, unsupported operating systems such as Windows 2000, the HDI 4000 Ultrasound System is built on an old operating system that is no longer supported. Thus, any unmitigated vulnerability in the old operating system could be exploited to affect this product. |
| In WebAccess/SCADA Versions 8.3.5 and prior, multiple out-of-bounds write vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution. |
| In WebAccess/SCADA, Versions 8.3.5 and prior, a path traversal vulnerability is caused by a lack of proper validation of a user-supplied path prior to use in file operations. An attacker can leverage this vulnerability to delete files while posing as an administrator. |
| Red Lion Controls Crimson, version 3.0 and prior and version 3.1 prior to release 3112.00, allow multiple vulnerabilities to be exploited when a valid user opens a specially crafted, malicious input file that causes the program to mishandle pointers. |
| In WebAccess/SCADA Versions 8.3.5 and prior, an out-of-bounds read vulnerability is caused by a lack of proper validation of user-supplied data. Exploitation of this vulnerability may allow disclosure of information. |
| Delta Electronics CNCSoft ScreenEditor, Versions 1.00.89 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, allowing an attacker to remotely execute arbitrary code. There is a lack of user input validation before copying data from project files onto the heap. |